AC100 Pro Technical Data Sheet
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Working Stress Design<br />
Concrete Temperature Range: 40ºC/24ºC (Maximum long term 24ºC and Maximum short term 40ºC).<br />
Concrete Thickness = 1xh min<br />
where h min<br />
as per ETA.<br />
Hole condition: Dry/wet, non-flooded hole.<br />
Drilling method: HAMMER DRILLED HOLES ONLY (Information is not valid for core drilled holes).<br />
Edge Distance: No concrete edge distance considered. (i.e. edge distance > maximum (10 X h eff<br />
& 60 X d) in all directions).<br />
Spacing between anchors: The values are for single anchors installed well away from concrete edges and other anchors. No spacing effects considered.<br />
UNCRACKED CONCRETE<br />
Single Anchor Load Capacities (kN) for Threaded Rod (static or quasi-static loads)<br />
Anchor<br />
Size<br />
(mm)<br />
Hole<br />
Size<br />
(mm)<br />
8 10<br />
10 12<br />
12 14<br />
16 18<br />
20 24<br />
24 28<br />
30 35<br />
Depth<br />
h eff<br />
(mm)<br />
Concrete<br />
Thickness<br />
(mm)<br />
Class 5.8 Threaded Rod Class 8.8 Threaded Rod A4-50 Stainless Steel<br />
Tension Load (Concrete) Shear<br />
Load<br />
(Steel)<br />
Tension Load (Concrete) Shear<br />
Load<br />
(Steel)<br />
Tension Load (Concrete) Shear<br />
Load<br />
(Steel)<br />
20MPa 32MPa 40MPa 50MPa 20MPa 32MPa 40MPa 50MPa 20MPa 32MPa 40MPa 50MPa<br />
60 100 5.5 5.8 6.0 6.1<br />
5.5 5.8 6.0 6.1<br />
80 110<br />
3.7 7.4 7.7 8.0 8.1<br />
7.3<br />
100 130 9.2 9.7 10.0 10.1<br />
60 100 7.8 8.6 8.8 9.0<br />
7.8 8.6 8.8 9.0<br />
90 120<br />
5.8 12.3 12.8 13.2 13.5<br />
11.6<br />
130 160 17.7 18.5 18.6<br />
70 100 9.9 12.0 12.4 12.6<br />
9.9 12.0 12.4 12.6<br />
110 140<br />
8.4 18.0 18.8 19.4 19.8<br />
16.9<br />
155 185 25.3 26.5 27.0<br />
80 116 12.0 15.2 17.0 18.7<br />
125 161 23.5 28.5 29.4 29.9 15.7 23.5 28.5 29.4 29.9<br />
215 251 31.3 46.8 49.1 50.1<br />
90 138 14.4 18.2 20.3 22.3<br />
170 218 37.3 47.2 49.0 37.3 47.2 50.0 50.9<br />
24.5<br />
210 258<br />
51.2 59.9 61.8 62.9<br />
49.0<br />
270 318 73.5 77.0 78.3<br />
5.9 5.2 2.6<br />
9.3<br />
13.5<br />
7.8 8.3<br />
8.3<br />
9.9 12.0 12.0<br />
12.0<br />
12.0 15.2 17.0 18.7 C-Pryout 12.0 15.2 17.0 18.7<br />
25.1 22.4<br />
14.4 18.2 20.3 22.3 C-Pryout 14.4 18.2 20.3 22.3<br />
39.2 35.0<br />
100 156 16.8 21.3 23.8 26.1 C-Pryout 16.8 21.3 23.8 26.1 C-Pryout 16.8 21.3 23.8 26.1<br />
210 266 51.2 64.8 68.4 69.7<br />
51.2 64.8 68.4 69.7<br />
250 306 66.5 70.5 35.3 66.5 79.0 81.4 82.9<br />
350 406 70.5 105.6 110.6 112.8<br />
56.4 50.4<br />
120 190 22.1 28.0 31.3 34.3 C-Pryout 22.1 28.0 31.3 34.3 C-Pryout 22.1 28.0 31.3 34.3<br />
270 340 74.7 84.4 87.0 88.6<br />
74.7 84.4 87.0 88.6<br />
300 370 87.5 93.8 96.7 98.5 87.5 93.8 96.7 98.5<br />
56.1<br />
350 420 104.5 109.5 112.1 104.5 109.5 112.8 114.9<br />
550 620 112.1 164.1 172.0 177.3 179.4<br />
89.7<br />
74.7 80.1<br />
80.1<br />
4.1<br />
6.0<br />
11.2<br />
17.5<br />
25.2<br />
40.0<br />
Capacity is limited by steel strength. C-Pryout: Capacity is limited by the shear concrete pry-out<br />