08.11.2017 Views

Product Catalogue 2017 | Mahn Medizinprodukte GmbH

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

58<br />

X-RAY QUALITY<br />

QUALITY CONTROL OF FILM PROCESSING | CONSTANCY CHECK<br />

Similar to illustration.<br />

SENSITOMETER SENSIX | 815100<br />

Sensitometer for exposure of a reproducible 21 step grey scale wedge<br />

onto a X-ray film. Operated by rechargeable batteries.<br />

Light sources:<br />

• Blue: films of max 460nm<br />

• Green: films of max 500nm<br />

• Exposure: 21 steps each 5×10mm<br />

• Density steps: 0,0 - 3,0 D<br />

• Increments: 0,15 D<br />

• Dimensions: 212 × 58 × 130 mm (w/d/h)<br />

IEC 61223-2-1, IEC 61674, DIN 6868-2<br />

Similar to illustration.<br />

DENSITOMETER DENSIX | 817100<br />

Digital densitometer for optical density measurements of X-ray films.<br />

Including calibrated single step reference film.<br />

Power supply 819050 required.<br />

• Display: 3-digit LCD display<br />

• Measuring range: 0,0 - 4,5 OD<br />

• Resolution: 0,02 D<br />

• Battery indicator: polarity and „Lo-Bat”<br />

• Dimensions: 240 × 100 × 110mm. (w/h/d)<br />

IEC 61223-2-1/ -2/ -3/ -4, IEC 61223-2-9/ -10/ -11, DIN EN IEC 61223-3-1/ -2/ -3/ -4, IEC 61674, DIN<br />

6868-1/ -2/ -3/ -4/ -5/ -7<br />

CONNY II – DIGITAL DOSEMETER | 820000<br />

Compact diagnostic X-ray quality control dosemeter for routine constancy<br />

tests of conventional radiography, fluoroscopy and mammography<br />

installations. Measuring dose and dose rate in Gy, Gy/s and time in<br />

sec. shown on digital LCD display. Auto-start, shut-off, reset and timer<br />

functions. Measuring of patients entrance dose and entrance dose rate<br />

in combination with a measuring phantom. Unit is calibrated in air kerma.<br />

Operated by rechargeable batteries.<br />

• Measuring ranges: 70/100 kV conventional, fluoroscopy | 30 kV mammography<br />

• Dose: 2 mGy - 9,999 Gy<br />

– resolution: 20 nGy - 5 mGy<br />

• Dose rate: 5 mGy/s - 500 mGy/s<br />

– resolution: 50 nGy/s - 10 μGy/s<br />

• Irradiation time: 1 - 999,9 sec<br />

– resolution: 10 ms<br />

Similar to illustration.<br />

IIEC 61674, DIN 6868-3, DIN 6868-4, DIN 6868-7,DIN 6868-13<br />

Instrument to be used in combination with a phantom:<br />

REX, NORMI 13, NORMI MAM or NORMI PAS (not included)<br />

STATUS: NOVEMBER <strong>2017</strong>