Steca Elektronik Catalog PV Off Grid (06|2018)
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
STECAMAT 862<br />
Processor-controlled charger for lead-acid<br />
batteries with communication feature<br />
The battery charger <strong>Steca</strong>mat 862 charges the battery gently and quickly<br />
thanks to a processor-controlled charging process. The <strong>Steca</strong>mat 862 thus<br />
enables the processing of damaged or totally discharged batteries, ensuring<br />
long service life. The IP 65-certified dust and splash-proof housing allows<br />
for outdoor installation. Data can be read and processed centrally thanks<br />
to the integrated RS-485 interface. With this communication interface, the<br />
various charging parameters can be adjusted and the charging current can be<br />
increased to a maximum of 35 A. The integrated interface allows for communication<br />
with buses that are equipped with an integrated bus identification<br />
module (BIM).<br />
STECA<br />
Quality<br />
127<br />
Product features<br />
∙∙IP 65 jet waterproof casing<br />
∙∙Half the charging time compared to simple, non-controlled<br />
chargers with the same rated current<br />
∙∙Optimal for charging batteries with liquid electrolyte and solid<br />
gel / absorbed electrolyte (AGM)<br />
∙∙Suitable for totally discharged batteries<br />
∙∙Constant battery operational readiness through integrated<br />
trickle charge<br />
∙∙Charging below the gassing voltage<br />
∙∙Optimal charging of damaged batteries<br />
∙∙Communication with bus identification module for vehicle identification,<br />
heating control and query of ignition status<br />
∙∙Interface for bidirectional communication<br />
535<br />
224<br />
Electronic protection functions<br />
∙∙Protection in the case of wrong or damaged batteries<br />
∙∙Battery overcharge protection<br />
∙∙<br />
Charger output protected against short circuits, reverse polarity<br />
and overvoltage<br />
Technical data<br />
226<br />
Displays<br />
∙∙Multi-coloured LED shows operating states<br />
Operation<br />
∙∙Charging parameters adjustable via RS-485<br />
Interfaces<br />
∙∙RS-485 for connection to the depot management software<br />
Charging rated voltage<br />
24 V<br />
Charging current 20 A (max. 35 A)<br />
End-of-charge voltage<br />
27.6 V<br />
Trickle charge voltage<br />
27.2 V<br />
Characteristic curve<br />
UoIUoIU<br />
<strong>Grid</strong> voltage 230 V AC ± 10 %<br />
<strong>Grid</strong> frequency<br />
50 Hz (45 Hz ... 65 Hz)<br />
Mains electricity 4.0 A (230 V)<br />
Discharge current during<br />
1 mA<br />
grid failure<br />
Protection class<br />
I<br />
Casing / ingress protection aluminium / plastic, IP 65<br />
Ambient temperature -40 °C ... +60 °C<br />
Cooling<br />
convection<br />
Dimensions X x Y x Z<br />
226 x 535 x 127 mm<br />
Weight<br />
approx. 11.5 kg<br />
Technical data at 25 °C / 77 °F<br />
91