Service Manual - Wacker Neuson
Service Manual - Wacker Neuson
Service Manual - Wacker Neuson
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Maintenance<br />
Stationary fuel pumps General<br />
Only refuel from stationary fuel pumps. Fuel from barrels or cans is usually contaminated.<br />
Even the smallest particles of dirt can cause:<br />
Increased engine wear<br />
Malfunctions in the fuel system and<br />
Reduced effectiveness of the fuel filters<br />
right<br />
wrong<br />
Fig. 2: Refuelling from a barrel<br />
Diesel fuel specification Use only high-grade fuels<br />
Refuelling from barrels<br />
If refuelling from barrels cannot be avoided, note the following points (see fig. 2):<br />
Barrels must neither be rolled nor tilted before refuelling<br />
Protect the suction pipe opening of the barrel pump with a fine-mesh strainer<br />
Immerse it down to a max. 15 cm above the floor of the barrel<br />
Only fill the tank using refuelling aids (funnels or filler pipes) with integral microfilter<br />
Keep all refuelling containers clean at all times<br />
Grade<br />
No. 2-D according to DIN<br />
51601<br />
No. 1-D according to DIN<br />
51601<br />
Cetane<br />
number<br />
Min. 45<br />
3-8 SERV-HB 1001 EN – Edition 1.1 * 1001s312.fm<br />
Use<br />
For normal outside temperatures<br />
For outside temperatures below 4 °C or for<br />
operation above 1500 m altitude