16.07.2018 Views

Refurb Projects July 2018

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INSULATION<br />

In-patient unit insulated with Kingspan<br />

Kingspan Insulation products<br />

have been installed<br />

throughout the envelope of<br />

the new in-patient unit at<br />

St David’s Hospice Care in Newport,<br />

creating a warm, comfortable<br />

environment for patients to receive<br />

first-class care.<br />

The 15-bed unit adjoins an<br />

existing day hospice, providing<br />

specialist support for patients with<br />

complex symptom management<br />

needs, end of life care and<br />

occasional respite care. Each room<br />

features a wet room and a private<br />

terrace, providing views of the<br />

newly-planted wildflower meadow<br />

and hills beyond. The Welsh<br />

Government has provided £3 million<br />

towards the cost of the unit which<br />

has been constructed by Andrew<br />

Scott Ltd.<br />

KKE Architects selected natural<br />

materials for the building cladding,<br />

including tumbled sandstone and<br />

cedar shingles, providing it with a<br />

welcoming external appearance. To<br />

ensure a slim external wall<br />

construction whilst also achieving<br />

the target U-value of 0.16 W/m2.K,<br />

Kingspan Kooltherm K8 Cavity Board<br />

was specified within the cavity wall<br />

sections of the construction.<br />

The unit, which holds an Energy<br />

Performance Certificate of A, also<br />

features a highly insulated floor and<br />

roof, with both elements achieving a<br />

U-value of 0.10 W/m2.K. To deliver<br />

this, almost 3000 m2 of Kingspan<br />

Kooltherm K3 Floorboard was fitted<br />

along with Kingspan Kooltherm K7<br />

Pitched Roof Board and Thermaroof<br />

TR27 LPC/FM.<br />

Kyle Fowler, Architectural<br />

Technologist at KKE Architects<br />

commented:<br />

“The Kingspan Insulation<br />

products delivered reliable<br />

performance, enabling us to achieve<br />

our desired design details. We were<br />

also able to contact their technical<br />

support team throughout the design<br />

process, ensuring the completed<br />

elements performed as expected”.<br />

Since the completion of the inpatient<br />

unit, Kingspan has launched<br />

its Kooltherm K100 range offering<br />

thermal conductivities of just 0.018<br />

W/m.K across all thicknesses. The<br />

expanding range now includes K103<br />

Floorboard, K107 Pitched Roof Board<br />

and K108 Cavity Board, helping<br />

buildings to achieve outstanding<br />

levels of thermal performance with<br />

a minimum construction thickness.<br />

Tel: +44 (0) 1544 387 384<br />

info@kingspaninsulation.co.uk<br />

www.kingspaninsulation.co.uk<br />

Rockwool passes the ‘Terminal 4’ accoustic test<br />

Noise pollution is an<br />

inevitable fact of life at<br />

busy airports, and results<br />

in hoteliers in these<br />

locations needing to minimise the<br />

impact of unwanted noise on their<br />

guests. Thanks to a pioneering<br />

approach from ROCKWOOL that is<br />

based on acoustic performance test<br />

data and use of its BBA (British<br />

Board of Agrément) approved A1<br />

rated RAINSCREEN DUO SLAB®<br />

insulation product, the new Crowne<br />

Plaza and Holiday Inn Express at<br />

London Heathrow Terminal 4 will be<br />

providing visitors with a peaceful<br />

and tranquil stay when it opens later<br />

this year.<br />

Connected via a convenient air<br />

bridge to Terminal 4, this dualbranded<br />

hotel development includes<br />

Crowne Plaza and a Holiday Inn<br />

Express, with a combined total of<br />

750 rooms. There is also a range of<br />

onsite business facilities, including<br />

five meeting rooms, to enable guests<br />

to be at their most productive<br />

during their stay. Minimising<br />

external noise from the UK’s busiest<br />

airport, where the average number<br />

of air transport movements reached<br />

1,295 per day in 2017, was a major<br />

factor in this build. To this end,<br />

Grove Developments, the<br />

construction division of The Arora<br />

Group, who is overseeing the<br />

project, challenged ROCKWOOL to<br />

achieve a significant Rw 58dB sound<br />

reduction within the façade system<br />

used on the development.<br />

Using test results from its<br />

Rainscreen Acoustic Reference<br />

Guide, and working closely with<br />

sub-contractor, SD Samuels,<br />

ROCKWOOL was able to demonstrate<br />

the exceptional performance<br />

capabilities of its 150mm<br />

RAINSCREEN DUO SLAB® product for<br />

the hotel development project. As a<br />

result, 5200m2 of the product was<br />

specified.<br />

RAINSCREEN DUO SLAB is a noncombustible,<br />

dual density insulation<br />

board that offers a robust outer<br />

surface and a resilient inner face<br />

designed for a variety of external<br />

cladding systems. Made from stone<br />

wool, RAINSCREEN DUO SLAB<br />

reduces noise intrusion into a<br />

building in multiple ways.<br />

As soundwaves try to pass<br />

through the air trapped within its<br />

fibrous structure, they get absorbed<br />

by friction as the individual fibres<br />

are made to move back and forth. In<br />

addition, the random orientation of<br />

the fibres makes it very difficult for<br />

sound to find a path from one side<br />

to the other. The top 15mm layer of<br />

each RAINSCREEN DUO SLAB board<br />

is manufactured at a higher density<br />

than the remainder of the board,<br />

changing its acoustic impedance so<br />

that sound is reflected at the<br />

interface between the two layers.<br />

RAINSCREEN DUO SLAB achieves<br />

an A1 Euroclass fire classification<br />

and is therefore non-combustible.<br />

The product also has the benefit of a<br />

high resistance to wind and rain<br />

during construction, which, together<br />

with the minimal number of fixings<br />

required, made installation quicker<br />

and easier for SD Samuels. At the<br />

Crowne Plaza and Holiday Inn<br />

Express, the product was tightly butt<br />

jointed, knitting together to deliver<br />

an effective thermal insulation with<br />

a U-value of 0.20 W/m2K. It has also<br />

minimised heat loss that could<br />

otherwise arise from gaps between<br />

insulation boards.<br />

For more information, visit<br />

www.rockwool.co.uk. To download a<br />

copy of the Rainscreen Acoustic<br />

Reference Guide, visit<br />

www.rockwool.co.uk/technicalsupport/documentation/brochures.<br />

20 JULY <strong>2018</strong>, REFURBISHMENT PROJECTS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!