INSULATION<br />
In-patient unit insulated with Kingspan<br />
Kingspan Insulation products<br />
have been installed<br />
throughout the envelope of<br />
the new in-patient unit at<br />
St David’s Hospice Care in Newport,<br />
creating a warm, comfortable<br />
environment for patients to receive<br />
first-class care.<br />
The 15-bed unit adjoins an<br />
existing day hospice, providing<br />
specialist support for patients with<br />
complex symptom management<br />
needs, end of life care and<br />
occasional respite care. Each room<br />
features a wet room and a private<br />
terrace, providing views of the<br />
newly-planted wildflower meadow<br />
and hills beyond. The Welsh<br />
Government has provided £3 million<br />
towards the cost of the unit which<br />
has been constructed by Andrew<br />
Scott Ltd.<br />
KKE Architects selected natural<br />
materials for the building cladding,<br />
including tumbled sandstone and<br />
cedar shingles, providing it with a<br />
welcoming external appearance. To<br />
ensure a slim external wall<br />
construction whilst also achieving<br />
the target U-value of 0.16 W/m2.K,<br />
Kingspan Kooltherm K8 Cavity Board<br />
was specified within the cavity wall<br />
sections of the construction.<br />
The unit, which holds an Energy<br />
Performance Certificate of A, also<br />
features a highly insulated floor and<br />
roof, with both elements achieving a<br />
U-value of 0.10 W/m2.K. To deliver<br />
this, almost 3000 m2 of Kingspan<br />
Kooltherm K3 Floorboard was fitted<br />
along with Kingspan Kooltherm K7<br />
Pitched Roof Board and Thermaroof<br />
TR27 LPC/FM.<br />
Kyle Fowler, Architectural<br />
Technologist at KKE Architects<br />
commented:<br />
“The Kingspan Insulation<br />
products delivered reliable<br />
performance, enabling us to achieve<br />
our desired design details. We were<br />
also able to contact their technical<br />
support team throughout the design<br />
process, ensuring the completed<br />
elements performed as expected”.<br />
Since the completion of the inpatient<br />
unit, Kingspan has launched<br />
its Kooltherm K100 range offering<br />
thermal conductivities of just 0.018<br />
W/m.K across all thicknesses. The<br />
expanding range now includes K103<br />
Floorboard, K107 Pitched Roof Board<br />
and K108 Cavity Board, helping<br />
buildings to achieve outstanding<br />
levels of thermal performance with<br />
a minimum construction thickness.<br />
Tel: +44 (0) 1544 387 384<br />
info@kingspaninsulation.co.uk<br />
www.kingspaninsulation.co.uk<br />
Rockwool passes the ‘Terminal 4’ accoustic test<br />
Noise pollution is an<br />
inevitable fact of life at<br />
busy airports, and results<br />
in hoteliers in these<br />
locations needing to minimise the<br />
impact of unwanted noise on their<br />
guests. Thanks to a pioneering<br />
approach from ROCKWOOL that is<br />
based on acoustic performance test<br />
data and use of its BBA (British<br />
Board of Agrément) approved A1<br />
rated RAINSCREEN DUO SLAB®<br />
insulation product, the new Crowne<br />
Plaza and Holiday Inn Express at<br />
London Heathrow Terminal 4 will be<br />
providing visitors with a peaceful<br />
and tranquil stay when it opens later<br />
this year.<br />
Connected via a convenient air<br />
bridge to Terminal 4, this dualbranded<br />
hotel development includes<br />
Crowne Plaza and a Holiday Inn<br />
Express, with a combined total of<br />
750 rooms. There is also a range of<br />
onsite business facilities, including<br />
five meeting rooms, to enable guests<br />
to be at their most productive<br />
during their stay. Minimising<br />
external noise from the UK’s busiest<br />
airport, where the average number<br />
of air transport movements reached<br />
1,295 per day in 2017, was a major<br />
factor in this build. To this end,<br />
Grove Developments, the<br />
construction division of The Arora<br />
Group, who is overseeing the<br />
project, challenged ROCKWOOL to<br />
achieve a significant Rw 58dB sound<br />
reduction within the façade system<br />
used on the development.<br />
Using test results from its<br />
Rainscreen Acoustic Reference<br />
Guide, and working closely with<br />
sub-contractor, SD Samuels,<br />
ROCKWOOL was able to demonstrate<br />
the exceptional performance<br />
capabilities of its 150mm<br />
RAINSCREEN DUO SLAB® product for<br />
the hotel development project. As a<br />
result, 5200m2 of the product was<br />
specified.<br />
RAINSCREEN DUO SLAB is a noncombustible,<br />
dual density insulation<br />
board that offers a robust outer<br />
surface and a resilient inner face<br />
designed for a variety of external<br />
cladding systems. Made from stone<br />
wool, RAINSCREEN DUO SLAB<br />
reduces noise intrusion into a<br />
building in multiple ways.<br />
As soundwaves try to pass<br />
through the air trapped within its<br />
fibrous structure, they get absorbed<br />
by friction as the individual fibres<br />
are made to move back and forth. In<br />
addition, the random orientation of<br />
the fibres makes it very difficult for<br />
sound to find a path from one side<br />
to the other. The top 15mm layer of<br />
each RAINSCREEN DUO SLAB board<br />
is manufactured at a higher density<br />
than the remainder of the board,<br />
changing its acoustic impedance so<br />
that sound is reflected at the<br />
interface between the two layers.<br />
RAINSCREEN DUO SLAB achieves<br />
an A1 Euroclass fire classification<br />
and is therefore non-combustible.<br />
The product also has the benefit of a<br />
high resistance to wind and rain<br />
during construction, which, together<br />
with the minimal number of fixings<br />
required, made installation quicker<br />
and easier for SD Samuels. At the<br />
Crowne Plaza and Holiday Inn<br />
Express, the product was tightly butt<br />
jointed, knitting together to deliver<br />
an effective thermal insulation with<br />
a U-value of 0.20 W/m2K. It has also<br />
minimised heat loss that could<br />
otherwise arise from gaps between<br />
insulation boards.<br />
For more information, visit<br />
www.rockwool.co.uk. To download a<br />
copy of the Rainscreen Acoustic<br />
Reference Guide, visit<br />
www.rockwool.co.uk/technicalsupport/documentation/brochures.<br />
20 JULY <strong>2018</strong>, REFURBISHMENT PROJECTS