Marathon Petroleum Company, Catlettsburg Refinery, KY<br />

Capacity Improvement <strong>Study</strong> of LPCCR Platformer Heater (1-44-B-1/2/3/4)<br />

Maximum Inside Film<br />

Temperature<br />

Maximum Tube Metal<br />

Temperature<br />

Parameter Unit Datasheet<br />

Simulation<br />

Output<br />

°F - 1,122<br />

°F 1,125 1,148<br />

Volumetric Heat Release Btu/hr/ft 3 - 2,807<br />

No.3 Inter heater (1-44-B-4)<br />

Heat Duty MMBtu/hr 13.98 13.22<br />

Heat Duty % 8.92 8.32<br />

Charge Flow Rate Lb/hr 211,731 211,731<br />

Inlet Temperature °F 934.0 943.3<br />

Inlet Pressure psig 63.0 63.1<br />

Outlet Temperature °F 1,010 1,010<br />

Outlet Pressure psig 61.3 61.3<br />

Coil Pressure Drop psi 1.7 1.8<br />

Radiant Heat Transfer Area ft 2 1,838 1,838<br />

Average Radiant Section Heat<br />

Flux<br />

Btu/hr/ft 2 7,605 7,193<br />

Max Rad. Section Heat Flux Btu/hr/ft 2 10,650 13,502<br />

Fluid Mass Velocity lb/sec/ft 2 - 23.8<br />

Bridge Wall Temperature °F 1,500 1,418<br />

Maximum Inside Film<br />

Temperature<br />

Maximum Tube Metal<br />

Temperature<br />

°F - 1,076<br />

°F 1,100 1,092<br />

Furnace Improvements<br />

Low Cost Solutions for Fired Heaters 30