25.02.2019 Views

FIS-483 Consolidated Engineering Study Report

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Marathon Petroleum Company, Catlettsburg Refinery, KY<br />

Capacity Improvement <strong>Study</strong> of LPCCR Platformer Heater (1-44-B-1/2/3/4)<br />

Parameter Unit Datasheet<br />

Outside Heat Transfer Fin<br />

Efficiency Factor<br />

Simulation<br />

Output<br />

- - -<br />

Maximum Fin Tip Temperature °F 590 481.5<br />

Boiler Feed Water Coils<br />

Heat Duty MMBtu/hr 6.55 6.80<br />

Heat Duty % 4.19 4.28<br />

Flow Rate Lb/hr 70,918 70,918<br />

Inlet Temperature °F 300.0 300.0<br />

Inlet Pressure Psig 470 470<br />

Outlet Temperature °F 385.0 391.6<br />

Outlet Pressure Psig 465.0 467.9<br />

Coil Pressure Drop Psi 5.0 2.1<br />

Heat Transfer Area (Finned) Ft 2 22,620 22,621<br />

Average BFW Coil Section Heat<br />

Flux (BOS)<br />

Btu/hr/Ft 2 2,758 2,863<br />

Fluid Mass Velocity Lb/s/Ft 2 - 123.4<br />

Flue Gas Mass Velocity Lb/s/Ft 2 0.258 0.300<br />

Outside Heat Transfer Fin<br />

Efficiency Factor<br />

- - -<br />

Flue Gas Pressure Drop in WC - 0.027<br />

Flue Gas Temperature Leaving<br />

BFW Coil Section<br />

°F 448 407<br />

Maximum Fin Tip Temperature °F 415 415<br />

Combustion<br />

Fuel Gas Heating Value (LHV) Btu/Scf 1,120 1,118<br />

Total Fuel Gas Flow Rate Lb/hr - 8,248<br />

Furnace Improvements<br />

Low Cost Solutions for Fired Heaters 32