13.1 Minimum thermal insulation according to GEG and surface heating standard DIN EN 1264<br />
Residential building with<br />
indoor temperature ≥ 19°C<br />
New buildings<br />
Consideration of building components:<br />
Ceilings downwards to the ground (floor slab)<br />
and to unheated rooms or to outside air<br />
Existing buildings<br />
Evidence according<br />
to GEG available?<br />
No<br />
Ref. value from reference<br />
house: R = 2,857 (m²·K)/W<br />
No<br />
Evidence according<br />
to GEG available?<br />
Yes<br />
2<br />
3<br />
4<br />
Yes<br />
Value from verification<br />
min. R = 2,00 (m²·K)/W<br />
against ground, outside air<br />
and unheated rooms<br />
2<br />
3<br />
4<br />
Yes<br />
Minimum value for<br />
comply with insulation<br />
Possible insulation height<br />
≥ 70 mm<br />
No<br />
Is also considered to be<br />
fulfilled if the highest<br />
possible insulation thickness<br />
according to insulation<br />
thickness is installed<br />
(see example)<br />
Value from verification<br />
but always comply with<br />
DIN EN 1264<br />
against ground and<br />
unheated rooms min.<br />
R = 1,25 (m²·K)/W<br />
2 3<br />
against outside air<br />
R = 2,00 (m²·K)/W<br />
4<br />
1<br />
Ceiling downwards to similarly heated<br />
rooms (≥ 19°C / ≥ 19 °C)<br />
Minimum value DIN EN 1264:<br />
R = 0,75 (m²·K)/W<br />
Ceiling<br />
2<br />
(floor plate) to<br />
ground adjacent<br />
(≥ 19°C / ≥ 0°C)<br />
Ceiling on<br />
3<br />
unheated room<br />
(cellar) adjacent<br />
(≥ 19°C / 6°C)<br />
4 Ceiling to<br />
outside air<br />
adjacent<br />
(≥ 19°C /<br />
-5°C bis -15°C)<br />
Example calculation highest possible insulation:<br />
max. possible insulation thickness: 60 mm<br />
R = 0,06 m/0,035 W/(m·K)<br />
R = 1,71 (m²·K)/W<br />
The installed insulation must have a minimum<br />
thermal resistance of R = 1,71 (m²·K)/W<br />
The reference value for the thermal conductivity λ<br />
applies here 0,035 W/(m·K)<br />
The "Act on Energy Saving and the Use of Renewable Energies for Heating and Cooling in Buildings (Building Energy Act –<br />
GEG)" came into force on November 1, 2020. It combines the EnEG (Energy Saving Act), the EEWärmeG (Renewable Energies<br />
Heat Act) and the EnEV (Energy Saving Ordinance) into one law. The purpose of the act (§ 1) is the most economical<br />
use of energy in buildings possible, including an increasing use of renewable energies ..., taking into account economic efficiency<br />
(§ 5) ..., if the requirements can be met according to the state of the art (§ 7)! The client or owner is responsible<br />
for compliance with the regulations (§ 8), ... and/or also persons acting on his behalf in the construction or alteration of<br />
buildings or the systems engineering in buildings.<br />
NOTE<br />
If a subsidy is applied for, e.g. "Federal subsidy for efficient buildings (BEG)",<br />
other values or specifications must be taken into account!<br />