4.4 Modelled performance – including the well pump<br />

General results from the model<br />

Annual energy available from PV 8820 kWh/y<br />

Annual hours run 2357 h/y<br />

Average hours run per day 6.46 h/d<br />

Annual water production 960 m 3 /y<br />

Average daily water production 2.63 m 3 /d<br />

Overall annual average specific energy 8820/960 = 9.19 kWh/m 3<br />

The annual energy available from the PV (8820 kWh/y) is unaffected by the addition of the well pump to the model. But, a<br />

considerable proportion of this energy is now used by the well pump, and so the annual water production predicted by the model is<br />

reduced from 1200 m 3 /y to 960 m 3 /y. This is reflected in the substantial increase in the overall specific energy, from 7.35 kWh/m 3 to<br />

9.19 kWh/m 3 .<br />

<strong>ADU</strong>–<strong>RES</strong> WP6 Deliverable 6.1 Page 28 of 69