Photovoltaic array<br />
Nominal array power 2.4 kWpeak<br />
Number of modules 20<br />
Wiring configuration 20 in series<br />
Nominal module power 120 Wpeak<br />
Module type Poly-crystalline<br />
Manufacturer AstroPower (now GE <strong>Energy</strong>) www.gepower.com<br />
Model AP-1206 http://www.oksolar.com/pdf/solar_energy_catalog/astro-power_ap120.pdf<br />
Cells per module 36 in series<br />
MPP voltage 16.9 V<br />
Inverters (both)<br />
Type Variable frequency drive (VFD)<br />
Manufacturer FKI Industrial Drives (see Invertek) www.invertek.co.uk<br />
Model FID1000 FKI-12150<br />
Rating 1.5 kW<br />
Nominal Input 230 V single-phase AC<br />
… or in this case 325 V DC<br />
Output Variable frequency three-phase AC. Nominal: 230 V at 50 Hz.<br />
Losses 14.5 W at 1.3 A motor current<br />
28.5 W at 3.4 A motor current<br />
Motors (both)<br />
Type 6-pole three-phase high-efficiency induction motor<br />
Power 1.5 kW<br />
Manufacturer Toshiba<br />
Model B0026FLF2AYH<br />
Full-load efficiency 85 % IEC (based on IEEE 88.4 %)<br />
European alternative:<br />
Manufacturer Siemens<br />
Model 1LA9 106-6KA<br />
Full-load efficiency 83.0 % IEC (88.4 % IEEE)<br />
<strong>ADU</strong>–<strong>RES</strong> WP6 Deliverable 6.1 Page 44 of 69