Output 230 V AC, 50 Hz, Single-phase<br />

Continuous rating 3000 VA<br />

Assume efficiency curve from: Trace, Xantrex, SW3024E, as per Inverter 1.<br />

Inverter 3 (also for AP pump)<br />

Type Variable frequency drive (VFD)<br />

Manufacturer LG Industrial Systems www.lgis.com<br />

Range Starvert-iC5 www.anadigi.co.za/documents/iC5/iC5.pdf<br />

Model SV022iC5-1<br />

Rating 2.2 kW<br />

Assume loss-current curve from:<br />

Manufacturer FKI Industrial Drives<br />

Model FID1000 FKI-12150<br />

Motor (for AP pump)<br />

Type Three-phase induction<br />

Manufacturer Valiadis<br />

Model Ê90L http://www.valiadis.gr/en/motors/2pmotorsen.htm<br />

Power 2.2 kW<br />

Frequency 50 Hz<br />

Rated speed 2850 rpm<br />

Efficiency 79 %<br />

Cos φ at full load 0.85<br />

Assume other parameters similar to:<br />

Manufacturer Brook Crompton<br />

Model T-DA(DF)90LA www.brookcrompton.com/pdf-files/2210E_issue3_1e.pdf<br />

Axial-piston pump<br />

Manufacturer Danfoss http://nessie.danfoss.com/products/pumps.asp<br />

Model APP 1.0 APP datasheet no.: DKCFN.PD.010.D4.02<br />

Geometric displacement 6.3 cm 3 /rev<br />

Volumetric efficiency 95 %<br />