Output 230 V AC, 50 Hz, Single-phase<br />
Continuous rating 3000 VA<br />
Assume efficiency curve from: Trace, Xantrex, SW3024E, as per Inverter 1.<br />
Inverter 3 (also for AP pump)<br />
Type Variable frequency drive (VFD)<br />
Manufacturer LG Industrial Systems www.lgis.com<br />
Range Starvert-iC5 www.anadigi.co.za/documents/iC5/iC5.pdf<br />
Model SV022iC5-1<br />
Rating 2.2 kW<br />
Assume loss-current curve from:<br />
Manufacturer FKI Industrial Drives<br />
Model FID1000 FKI-12150<br />
Motor (for AP pump)<br />
Type Three-phase induction<br />
Manufacturer Valiadis<br />
Model Ê90L http://www.valiadis.gr/en/motors/2pmotorsen.htm<br />
Power 2.2 kW<br />
Frequency 50 Hz<br />
Rated speed 2850 rpm<br />
Efficiency 79 %<br />
Cos φ at full load 0.85<br />
Assume other parameters similar to:<br />
Manufacturer Brook Crompton<br />
Model T-DA(DF)90LA www.brookcrompton.com/pdf-files/2210E_issue3_1e.pdf<br />
Axial-piston pump<br />
Manufacturer Danfoss http://nessie.danfoss.com/products/pumps.asp<br />
Model APP 1.0 APP datasheet no.: DKCFN.PD.010.D4.02<br />
Geometric displacement 6.3 cm 3 /rev<br />
Volumetric efficiency 95 %<br />