GE98‐01B: Specification <strong>for</strong> Thermal Barrier Coating of GTD‐111 ® Combustion<br />

Turbine Buckets. March 2000.<br />

This specification establishes the minimum technical requirements <strong>for</strong> applying a two‐layer<br />

(metallic <strong>and</strong> ceramic) thermal barrier coating (TBC) on GTD‐111, nickel –base alloy substrates.<br />

GE98‐<strong>02</strong>: The Life Cycle Value of TBC Coatings on MS7001E/EA First Stage<br />

Nozzles <strong>and</strong> Buckets. February 2000.<br />

The purpose of this project was to investigate the life cycle value of TBC coatings on GE<br />

MS7001E/EA 1 st stage turbine nozzles <strong>and</strong> buckets. The life cycle cost/benefit analysis indicated<br />

that the combined, net present worth of older style 1 st stage nozzles <strong>and</strong> buckets could be<br />

increased by between $225,000 <strong>and</strong> $4,200,000 over a 12‐year analysis period <strong>for</strong> a single unit<br />

plant. The net present worth was maximized using strategies that involved increasing the firing<br />

temperature from 2<strong>02</strong>0°F from 2035°F. The economic benefits were greatest <strong>for</strong> MS7001E/EA<br />

units in continuous vs. peaking duty.<br />

GE98‐06: MS7001E/EA 1 st Stage Parts Life Extension vs. Expedited Depletion.<br />

July 1999.<br />

The purpose of this project was to per<strong>for</strong>m an analysis of expedited GE MS7001E/EA 1 St stage<br />

nozzle <strong>and</strong> bucket life depletion under uprated (2035?F) operating conditions.<br />

The life cycle cost/benefit analysis indicated that the combined net present worth of older style<br />

1 st stage nozzles <strong>and</strong> buckets could be increased by between $450,000 <strong>and</strong> $1,190,000 over a<br />

12‐year analysis period <strong>for</strong> a single unit plant. These gains were realized through O&M<br />

strategies that included (1) expedited life depletion, (2) repair <strong>and</strong> re‐use (including the<br />

application of TBC coatings) <strong>and</strong> (3) the replacement of older style components with<br />

conventionally cast, 1 st stage buckets with TBCs vs. upgrading to current design DS GTD‐111<br />

buckets.