23.12.2012 Views

SICK Product Catalog "Industrial Safety Systems" - Sensors ...

SICK Product Catalog "Industrial Safety Systems" - Sensors ...

SICK Product Catalog "Industrial Safety Systems" - Sensors ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Safety</strong> controllers and fieldbus systems<br />

Ordering information<br />

7024240<br />

Functionality<br />

<strong>Safety</strong> remote I/O and<br />

safety controller<br />

Detailed technical specifications<br />

General system data<br />

<strong>Safety</strong> remote controller UE4427/ UE4457<br />

UE4427-03DC9F0 UE4457-03DC9F0<br />

Fieldbus Stand-alone operation, DeviceNet and/or DeviceNet <strong>Safety</strong><br />

<strong>Safety</strong> category Up to category 4 (EN 954-1)<br />

<strong>Safety</strong> integrity level Up to SIL 3 (IEC 61508)<br />

Supply voltage 19.2 V DC ... 28.8 V DC<br />

Connection type supply voltage Mini 7/8" × 4<br />

Ambient operating temperature from ... to –10 °C ... +55 °C<br />

Enclosure rating IP 67<br />

Protection class III (IEC 61131-2)<br />

Vibration resistance according to IEC 60068-2-6 0.35 mm, 10 Hz ... 57 Hz, 50 m/sec², 57 Hz ... 150 Hz<br />

Shock resistance 150 g, 11 ms (IEC 60068-2-27)<br />

Mounting Location in the vincinity of the equipment<br />

Weight 570 g 650 g<br />

Field signal connections<br />

Connection type 5-pole M12 connector<br />

Number of safety inputs<br />

Type of output on the field-signal input<br />

Input voltage HIGH<br />

Input voltage LOW<br />

Input current HIGH<br />

Input delay<br />

6 dual-channel resp. 12 single-channel<br />

PNP or contact<br />

11 V DC ... 30 V DC<br />

–30 V DC ... 5 V DC<br />

5 mA<br />

0 ms ... 635 ms, configurable<br />

Number of SDL connections<br />

<strong>Safety</strong> outputs<br />

— 2<br />

Number of safety capable outputs<br />

2 dual-channel<br />

Type of output<br />

Bipolar type<br />

Maximum response time<br />

15 ms<br />

Switching current<br />

2 A<br />

Leakage current<br />

0.5 mA<br />

Test/signal outputs<br />

Output current per channel<br />

700 mA<br />

Leakage current<br />

Max. 0.5 mA<br />

DeviceNet <strong>Safety</strong> connections<br />

Number of<br />

safety inputs<br />

6 dual-channel resp.<br />

12 single-channel<br />

Number of safety target connections<br />

Expected packet interval (EPI) setting<br />

Single cast I/O support<br />

Multi cast I/O support<br />

Number of safety<br />

capable outputs<br />

2 dual-channel,<br />

bipolar type<br />

Number of SDL connections<br />

Type Part number<br />

— UE4427-03DC9F0 1028304<br />

2 UE4457-03DC9F0 1028307<br />

Max. 6<br />

10 ms minimum, 5 ms increments<br />

16 Bytes/16 Bytes<br />

16 Bytes/16 Bytes<br />

© <strong>SICK</strong>, Inc., USA. All rights, including changes to technical specifications<br />

and or to the equipment without prior notification, are reserved.<br />

O - 67<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

I<br />

J<br />

K<br />

L<br />

M<br />

N<br />

O<br />

P<br />

Q<br />

R

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!