<strong>Safety</strong> controllers and fieldbus systems<br />
Connection diagrams<br />
➜ You can find connection diagrams at www.sickusa.com/connectiondiagrams<br />
<strong>Safety</strong> remote controller UE4427/ UE4457<br />
Emergency stop, emergency shutdown, safety door on the field-signal connection<br />
Single-channel<br />
(up to category 2)<br />
Out A<br />
Out B<br />
In B<br />
In A<br />
GND<br />
7024240<br />
Dual-channel with<br />
common testing<br />
(up to category 3)<br />
Out A<br />
Out B<br />
In B<br />
In A<br />
GND<br />
Depending on the control category required, you can realise the<br />
emergency stop using a single-channel, dual-channel with common<br />
testing or dual-channel with isolated testing.<br />
The classification of components fitted with contacts (e.g. safety<br />
door switches and emergency stops) into a control category<br />
Dual-channel with<br />
isolated testing<br />
(up to category 4)<br />
Out A<br />
Out B<br />
In B<br />
In A<br />
GND<br />
depends both on the connection type (single-channel/dualchannel)<br />
and on the execution (single/redundant, testing type).<br />
You must therefore always select the appropriate switching element<br />
for the required control category and switching type.<br />
Electrosensitive protective equipment (ESPE) on the field-signal connection<br />
24 V<br />
Out A<br />
Out B<br />
In B<br />
In A<br />
GND<br />
24 V<br />
In the connection of electrosensitive protective equipment<br />
(ESPE), sender and receiver can be considered as a system’s<br />
input and output.<br />
Control switch with indicator display on the field-signal connection<br />
The indicator display (Out A) is being controlled via the internal<br />
logic of the UE44X7 or via an external safety rated programmable<br />
logic controller.<br />
Muting lamp on the field-signal connection<br />
It is only permitted to connect a muting lamp to test output 1A,<br />
as only this output has current monitoring capability.<br />
24 V<br />
OSSD2<br />
OSSD1<br />
Out A<br />
Out B<br />
In B<br />
In A<br />
GND<br />
You can use output Out B to test the sender in a safety light curtain.<br />
The safety outputs (output signal switching devices [OSSDs])<br />
are connected to inputs In A and In B.<br />
© <strong>SICK</strong>, Inc., USA. All rights, including changes to technical specifications<br />
and or to the equipment without prior notification, are reserved.<br />
O - 71<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
I<br />
J<br />
K<br />
L<br />
M<br />
N<br />
O<br />
P<br />
Q<br />
R