23.12.2012 Views

SICK Product Catalog "Industrial Safety Systems" - Sensors ...

SICK Product Catalog "Industrial Safety Systems" - Sensors ...

SICK Product Catalog "Industrial Safety Systems" - Sensors ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Safety</strong> controllers and fieldbus systems<br />

Connection diagrams<br />

➜ You can find connection diagrams at www.sickusa.com/connectiondiagrams<br />

<strong>Safety</strong> remote controller UE4427/ UE4457<br />

Emergency stop, emergency shutdown, safety door on the field-signal connection<br />

Single-channel<br />

(up to category 2)<br />

Out A<br />

Out B<br />

In B<br />

In A<br />

GND<br />

7024240<br />

Dual-channel with<br />

common testing<br />

(up to category 3)<br />

Out A<br />

Out B<br />

In B<br />

In A<br />

GND<br />

Depending on the control category required, you can realise the<br />

emergency stop using a single-channel, dual-channel with common<br />

testing or dual-channel with isolated testing.<br />

The classification of components fitted with contacts (e.g. safety<br />

door switches and emergency stops) into a control category<br />

Dual-channel with<br />

isolated testing<br />

(up to category 4)<br />

Out A<br />

Out B<br />

In B<br />

In A<br />

GND<br />

depends both on the connection type (single-channel/dualchannel)<br />

and on the execution (single/redundant, testing type).<br />

You must therefore always select the appropriate switching element<br />

for the required control category and switching type.<br />

Electrosensitive protective equipment (ESPE) on the field-signal connection<br />

24 V<br />

Out A<br />

Out B<br />

In B<br />

In A<br />

GND<br />

24 V<br />

In the connection of electrosensitive protective equipment<br />

(ESPE), sender and receiver can be considered as a system’s<br />

input and output.<br />

Control switch with indicator display on the field-signal connection<br />

The indicator display (Out A) is being controlled via the internal<br />

logic of the UE44X7 or via an external safety rated programmable<br />

logic controller.<br />

Muting lamp on the field-signal connection<br />

It is only permitted to connect a muting lamp to test output 1A,<br />

as only this output has current monitoring capability.<br />

24 V<br />

OSSD2<br />

OSSD1<br />

Out A<br />

Out B<br />

In B<br />

In A<br />

GND<br />

You can use output Out B to test the sender in a safety light curtain.<br />

The safety outputs (output signal switching devices [OSSDs])<br />

are connected to inputs In A and In B.<br />

© <strong>SICK</strong>, Inc., USA. All rights, including changes to technical specifications<br />

and or to the equipment without prior notification, are reserved.<br />

O - 71<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

H<br />

I<br />

J<br />

K<br />

L<br />

M<br />

N<br />

O<br />

P<br />

Q<br />

R

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!