<strong>Safety</strong> controllers and fieldbus systems<br />

Field-signal connections<br />

DeviceNet network connections<br />

7024240<br />

<strong>Safety</strong> remote I/Os UE4421<br />

UE4421-22EE900 UE4421-22EE330 UE4421-22EE490<br />

Connection type Spring terminal plug<br />

Number of safety inputs<br />

<strong>Safety</strong> outputs<br />

Type of output on the field-signal input<br />

Input voltage HIGH<br />

Input voltage LOW<br />

Input current HIGH<br />

Input delay<br />

Number of safety capable outputs<br />

Type of output<br />

Maximum response time<br />

Switching current<br />

Leakage current<br />

Mechanical life (relay contacts)<br />

Electrical life (relay contacts)<br />

Test/signal outputs<br />

Number of test/signal outputs (with current<br />

monitoring)<br />

Output current per channel<br />

Leakage current<br />

DeviceNet <strong>Safety</strong> network connections<br />

Number of safety target connections<br />

Expected packet interval (EPI) setting<br />

Single cast I/O support<br />

Multi cast I/O support<br />

6 dual-channel resp.<br />

12 single-channel<br />

PNP or contact<br />

11 V DC ... 26.4 V DC<br />

0 V DC ... 5 V DC<br />

6 mA<br />

0 ms ... 126 ms,<br />

configurable<br />

Poll connection maximum I/O transmission rate 5 Bytes/5 Bytes<br />

Number of standard slave connections Max. 2<br />

Number of UCMM server Max. 2<br />

Connection type Spring terminal block<br />

DeviceNet communication rate 125 KBit/s, 250 KBit/s, 500 KBit/s, Autobaud Detection<br />

DeviceNet communication rate setting method Automatic (Autobaud Only)<br />

DeviceNet addressing Via safety network configuration tool (e.g. <strong>SICK</strong> DeviceNet <strong>Safety</strong> Configurator)<br />

or rotary switches<br />

—<br />

—<br />

15 ms<br />

—<br />

—<br />

—<br />

—<br />

2 dual-channel resp.<br />

4 single-channel<br />

PNP or contact<br />

11 V DC ... 26.4 V DC<br />

0 V DC ... 5 V DC<br />

6 mA<br />

0 ms ... 126 ms,<br />

configurable<br />

2 dual-channel resp.<br />

4 single-channel<br />

Relay type<br />

15 ms<br />

2 A<br />

—<br />

5 x 10 6 switching cycles<br />

1 x 10 5 switching cycles<br />

4 (1)<br />

700 mA<br />

Max. 0.1 mA<br />

Max. 4<br />

6 ms ... 1 ms<br />

5 Bytes/5 Bytes<br />

5 Bytes/5 Bytes<br />

© <strong>SICK</strong>, Inc., USA. All rights, including changes to technical specifications<br />

and or to the equipment without prior notification, are reserved.<br />

4 dual-channel resp.<br />

8 single-channel<br />

PNP or contact<br />

11 V DC ... 26.4 V DC<br />

0 V DC ... 5 V DC<br />

6 mA<br />

0 ms ... 126 ms,<br />

configurable<br />

4 dual-channel resp.<br />

8 single-channel<br />

Current sourcing (PNP)<br />

15 ms<br />

500 mA<br />

0.1 mA<br />

—<br />