25.12.2012 Views

Air Cooled Packaged Modular Chiller Model UCA - ClimaCool ...

Air Cooled Packaged Modular Chiller Model UCA - ClimaCool ...

Air Cooled Packaged Modular Chiller Model UCA - ClimaCool ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

26<br />

Start�Up�and�Warranty�Registration�Form�<br />

(<strong>Air</strong>�<strong>Cooled</strong>)�<br />

Sign,�date�and�E�mail�to�customerservice@climacoolcorp.com�or�<br />

Fax:�(405)�745�2072�Attn:�Customer�Service.�<br />

Page�2�of�2�<br />

�<br />

Circuit�#�2� �<br />

Amperage� � ������ � ���������������L1�________������������L2�________������L3�________�<br />

�<br />

� � � � � � � � Comments:� � � �<br />

Sight�Glass�Oil�Level� ���________� _______________________________�<br />

Suction�Pressure�(PSIG)� � � � � � � � ________� _______________________________�<br />

Suction�Temperature�(°F)�� � � � � � � ________� _______________________________�<br />

Compressor�Superheat�(°F)� � � � � � � ________� _______________________________�<br />

Discharge�Pressure�(PSIG)�� � � � � � � ________� _______________________________�<br />

Discharge�Temperature�(°F)� � � � � � � ________� _______________________________�<br />

Evaporator�Entering�Water�Temperature�(°F)�� ________� _______________________________�<br />

Evaporator�Leaving�Water�Temperature�(°F)� � ________� _______________________________�<br />

Condenser�Entering�<strong>Air</strong>�Temperature�(°F)�� � ________� _______________________________�<br />

Condenser�Leaving�<strong>Air</strong>�Temperature�(°F)����� � ________� _______________________________�<br />

Condenser�Liquid�Line�Temperature�(°F)� � � ________� _______________________________�<br />

Condenser�Liquid�Subcooling�Temperature�(°F)� ________� _______________________________�<br />

Evaporator�Pressure�Differential�(PSIG)�� � � ________� _______________________________�<br />

�<br />

Verify�Safety�Settings:��� � Low�Limit____�High�Pressure�Limit�____Low�Pressure�Limit�____�<br />

�<br />

NOTE:��Correct�rotation�of�scroll�compressors�is�extremely�critical.��Incorrect�rotation�could�damage�the�<br />

compressor.�<br />

�<br />

�<br />

Contractor�Name:� ����___________________________�� � � �<br />

Address:�� � � ����___________________________�� � � � � �<br />

� � � � � ����___________________________�� � � __________________________________�<br />

Phone:� � � � ���____________________________� � ��������������������������(Authorized�Signature)�� � � �<br />

� �<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

� � � �<br />

www.climacoolcorp.com