Physical Data<br />

6<br />

<strong>Model</strong>�<strong>UCA</strong>� 20 30<br />

Capacity�(Tons)¹<br />

19.0 28.7<br />

EER 10.8 10.8<br />

Refrigerant�Circuits�(quantity)<br />

2 2<br />

Compressor�Type<br />

scroll scroll<br />

Compressor�Quantity<br />

2 2<br />

Compressor�Nominal�Hp�(per�circuit)<br />

10 15<br />

Refrigerant�Charge�(per�circuit)�R�410A�(lbs)<br />

39 48<br />

Module�Operating�Weight�w/Water�(lbs)³<br />

1,710 1,870<br />

Module�Shipping�Weight�(lbs)�<br />

1,495 1,655<br />

Condenser�Fans<br />

20 30<br />

Motor�Type<br />

T.E. T.E.<br />

HP 1.5 1.5<br />

Quantity<br />

1 2<br />

Fan�Type �Axial Axial<br />

Diameter 31.5" 31.5<br />

<strong>Air</strong>flow�(cfm�per�circuit) 6000 9,800<br />

RPM 850 850<br />

Maximum�Design�Working�Pressure���refrigerant�(PSI)<br />

650 650<br />

Condenser�Coils<br />

20 30<br />

Fin�Material Aluminum Aluminum<br />

Tube�Material Copper Copper<br />

Dimensions�(Quantity) 22"�x�78"�(4) 22"�x�78"�(4)<br />

Rows�Deep 3 4<br />

Fins�Per�Inch 12 12<br />

Evaporator<br />

Heat�Exchanger�(Type)<br />

Independent�Refrigerant�Circuits�(quantity)<br />

Water�Storage�Volume�HX�Only�(gals.)<br />

Water�Storage�Volume�HX�Plus�6"�Main�Headers�(gals)<br />

Flow�Rate�(GPM)�<br />

Maximum�Design�Working�Pressure���Water�Side�(PSI)<br />

Header�Water�Connections���Inlet/Outlet�(inches)²<br />

www.climacoolcorp.com<br />

20 30<br />

Brazed�Plate Brazed�Plate<br />

2 2<br />

2.6 2.6<br />

39.6 39.6<br />

Min 23 35<br />

Max 77 116<br />

300 300<br />

6" 6"<br />

Notes:<br />

1.��Unit�tonnage�ARI�rating�conditions:��44°F�leaving�chilled�water�temperature,�95°F�entering�condenser�air�temprature,�flow�rate�is<br />

�����2.4�GPM�per�ton�through�the�evaporator�with�a�.0001�fouling�factor.�<br />

2.��Main�header�water/fluid�connections�are�ASME,�6"�scheduled�40�pipe�with�grooved�couplings,�300�psig�manimum�working�pressure.<br />

3.��Module�operational�weight�includes�water,�compressor�oil,�and�refrigerant�charge.��Multiply�times�the�number�of�modules�for�a<br />

������total�system�operational�weight.��<br />

4.��Unit�shipping�weight�includes�refrigerant�charge,�compressor�oil�and�packaging.<br />

5.��The�minimum/maximum�flow�rates�are�based�on�an�approximate�temperature�differential�of�5.9°F�to�20°F�through�the�evaporator.��