Description of the <strong>Synchronous</strong> Motor<br />
1.1 Features, system prerequisites<br />
Accuracy<br />
1-20<br />
The precision of a motor sp<strong>in</strong>dle is def<strong>in</strong>ed on one hand by the mechanical design<br />
and on the other hand by the control technology and the encoder resolution.<br />
Mechanical system<br />
The mach<strong>in</strong><strong>in</strong>g precision of the sp<strong>in</strong>dle that can be achieved is <strong>in</strong>fluenced, <strong>in</strong> addition<br />
to the system stiffness (hous<strong>in</strong>g, bear<strong>in</strong>gs, sp<strong>in</strong>dle), also by its smooth runn<strong>in</strong>g<br />
properties. The sp<strong>in</strong>dle manufacturer is responsible for the implementation and<br />
prov<strong>in</strong>g the correspond<strong>in</strong>g performance.<br />
!<br />
Warn<strong>in</strong>g<br />
Static charg<strong>in</strong>g of the rotor:<br />
At higher speeds, depend<strong>in</strong>g on the sp<strong>in</strong>dle design as well as the properties of the<br />
sp<strong>in</strong>dle bear<strong>in</strong>gs (e.g. grease and m<strong>in</strong>imum oil lubrication), the rotor can be<br />
statically charged--up! The sp<strong>in</strong>dle manufacturer must apply the appropriate<br />
counter--measures.<br />
If ceramic bear<strong>in</strong>gs are used, the motor shaft must be grounded as otherwise<br />
arc<strong>in</strong>g could occur between the shaft and the sensor hous<strong>in</strong>g!<br />
Closed -loop control<br />
The decisive closed--loop control factors <strong>in</strong>clude:<br />
S The number of encoder signals per sp<strong>in</strong>dle revolution<br />
S The precision when mount<strong>in</strong>g and adjust<strong>in</strong>g the encoder system<br />
S The multiplication of the encoder signals<br />
S The sampl<strong>in</strong>g time of the current and speed controller<br />
In conjunction with the Performance control (closed--loop) of SIMODRIVE 611 digital,<br />
the motor sp<strong>in</strong>dle is suitable for C--axis operation.<br />
Degree of protection<br />
The motor components have degree of protection IP00.<br />
The f<strong>in</strong>al degree of protection is determ<strong>in</strong>ed by the mechanical design of the<br />
sp<strong>in</strong>dle hous<strong>in</strong>g of the particular manufacturer. Protection aga<strong>in</strong>st com<strong>in</strong>g <strong>in</strong>to contact,<br />
foreign bodies and water for electrical equipment is specified <strong>in</strong> accordance<br />
with DIN IEC 60034, Part 5.<br />
Recommendation: IP54 (m<strong>in</strong>imum degree of protection)<br />
Magnetic excitation<br />
Forces occur between the rotor and stator of electrical motors due to the <strong>in</strong>herent<br />
magnetic pr<strong>in</strong>ciple of operation.<br />
These forces must be able to be absorbed by the surround<strong>in</strong>g mechanical assembly.<br />
In order to avoid excit<strong>in</strong>g vibration, the motor sp<strong>in</strong>dle (sp<strong>in</strong>dle shaft, bear<strong>in</strong>gs,<br />
sp<strong>in</strong>dle hous<strong>in</strong>g) should be designed to be as stiff as possible.<br />
<strong>Synchronous</strong> <strong>Built</strong>-<strong>in</strong> <strong>Motors</strong> <strong>1FE1</strong><br />
<strong>Configuration</strong> <strong>Manual</strong> (PJFE), 09/2008, 6SN1197 -0AC00 -1BP0