Description of the <strong>Synchronous</strong> Motor<br />

1.1 Features, system prerequisites<br />

Accuracy<br />

1-20<br />

The precision of a motor sp<strong>in</strong>dle is def<strong>in</strong>ed on one hand by the mechanical design<br />

and on the other hand by the control technology and the encoder resolution.<br />

Mechanical system<br />

The mach<strong>in</strong><strong>in</strong>g precision of the sp<strong>in</strong>dle that can be achieved is <strong>in</strong>fluenced, <strong>in</strong> addition<br />

to the system stiffness (hous<strong>in</strong>g, bear<strong>in</strong>gs, sp<strong>in</strong>dle), also by its smooth runn<strong>in</strong>g<br />

properties. The sp<strong>in</strong>dle manufacturer is responsible for the implementation and<br />

prov<strong>in</strong>g the correspond<strong>in</strong>g performance.<br />

!<br />

Warn<strong>in</strong>g<br />

Static charg<strong>in</strong>g of the rotor:<br />

At higher speeds, depend<strong>in</strong>g on the sp<strong>in</strong>dle design as well as the properties of the<br />

sp<strong>in</strong>dle bear<strong>in</strong>gs (e.g. grease and m<strong>in</strong>imum oil lubrication), the rotor can be<br />

statically charged--up! The sp<strong>in</strong>dle manufacturer must apply the appropriate<br />

counter--measures.<br />

If ceramic bear<strong>in</strong>gs are used, the motor shaft must be grounded as otherwise<br />

arc<strong>in</strong>g could occur between the shaft and the sensor hous<strong>in</strong>g!<br />

Closed -loop control<br />

The decisive closed--loop control factors <strong>in</strong>clude:<br />

S The number of encoder signals per sp<strong>in</strong>dle revolution<br />

S The precision when mount<strong>in</strong>g and adjust<strong>in</strong>g the encoder system<br />

S The multiplication of the encoder signals<br />

S The sampl<strong>in</strong>g time of the current and speed controller<br />

In conjunction with the Performance control (closed--loop) of SIMODRIVE 611 digital,<br />

the motor sp<strong>in</strong>dle is suitable for C--axis operation.<br />

Degree of protection<br />

The motor components have degree of protection IP00.<br />

The f<strong>in</strong>al degree of protection is determ<strong>in</strong>ed by the mechanical design of the<br />

sp<strong>in</strong>dle hous<strong>in</strong>g of the particular manufacturer. Protection aga<strong>in</strong>st com<strong>in</strong>g <strong>in</strong>to contact,<br />

foreign bodies and water for electrical equipment is specified <strong>in</strong> accordance<br />

with DIN IEC 60034, Part 5.<br />

Recommendation: IP54 (m<strong>in</strong>imum degree of protection)<br />

Magnetic excitation<br />

Forces occur between the rotor and stator of electrical motors due to the <strong>in</strong>herent<br />

magnetic pr<strong>in</strong>ciple of operation.<br />

These forces must be able to be absorbed by the surround<strong>in</strong>g mechanical assembly.<br />

In order to avoid excit<strong>in</strong>g vibration, the motor sp<strong>in</strong>dle (sp<strong>in</strong>dle shaft, bear<strong>in</strong>gs,<br />

sp<strong>in</strong>dle hous<strong>in</strong>g) should be designed to be as stiff as possible.<br />

<strong>Synchronous</strong> <strong>Built</strong>-<strong>in</strong> <strong>Motors</strong> <strong>1FE1</strong><br />

<strong>Configuration</strong> <strong>Manual</strong> (PJFE), 09/2008, 6SN1197 -0AC00 -1BP0