<strong>Synchronous</strong> <strong>Built</strong>-<strong>in</strong> <strong>Motors</strong> <strong>1FE1</strong><br />

<strong>Configuration</strong> <strong>Manual</strong> (PJFE), 09/2008, 6SN1197 -0AC00 -1BP0<br />

Description of the <strong>Synchronous</strong> Motor<br />

1.3 Technical data<br />

Select<strong>in</strong>g the power units<br />

The required power units are selected accord<strong>in</strong>g to the peak currents and cont<strong>in</strong>uous<br />

currents that occur <strong>in</strong> the load duty cycle. If several motors are operated <strong>in</strong><br />

parallel with one drive converter, then the summed values of the peak and cont<strong>in</strong>uous<br />

currents must be taken <strong>in</strong>to account.<br />

Notice<br />

For system configurations, where built--<strong>in</strong> motors are used together with regulated<br />

(closed--loop control) <strong>in</strong>feed units, electrical oscillations can occur with respect to<br />

ground potential.<br />

These oscillations result <strong>in</strong> <strong>in</strong>creased voltage stress<strong>in</strong>g.<br />

Factors that <strong>in</strong>fluence these system oscillations <strong>in</strong>clude, among others<br />

-- Cable lengths<br />

-- Size of the <strong>in</strong>feed and regenerative feedback module<br />

-- Number of axes<br />

-- Motor size<br />

-- W<strong>in</strong>d<strong>in</strong>g design<br />

If <strong>in</strong>creased voltage stress<strong>in</strong>g occurs or if the ma<strong>in</strong> <strong>in</strong>sulation is damaged, an HFD<br />

reactor with damp<strong>in</strong>g resistor should be used to dampen the system oscillations.<br />

Table 1-3 Order No. of power units<br />

Current [A] Order No. [MLFB] of the power units<br />

8/10/16 6SN1123--1AA00--0BA1<br />

24/32/32 6SN1123--1AA00--0CA1<br />

30/40/51 6SN1123--1AA00--0DA1<br />

45/60/76 6SN1123--1AA00--0LA1<br />

60/80/102 6SN1123--1AA00--0EA1<br />

85/110/127 6SN1123--1AA00--0FA1<br />

120/150/193 6SN1123--1AA00--0JA1<br />

200/250/257 6SN1123--1AA00--0KA1<br />

Us<strong>in</strong>g smaller power units<br />

Note<br />

When smaller power units are used, for several motor types, the complete speed<br />

range cannot be used (even when the motor utilization is somewhat lower). Please<br />

contact your local <strong>Siemens</strong> office.<br />