Vibration system 26.7 kN (6000 lbf)<br />

TIRA <strong>vibration</strong> generators reproduce ambient conditions for<br />

studies of endurance and reliability in all fields of <strong>vibration</strong><br />

<strong>test</strong>ing. Sine/random/mixed mode and shock <strong>test</strong>s are simulated<br />

in a lab, using <strong>com</strong>plete <strong>systems</strong> which are indispensable for<br />

quality assurance, research and development. Designed for longtime<br />

operation, the generators are characterized by high cross<br />

axial stiffness. Electrodynamic generators are supported in a rugged<br />

construction with a maximum of stability and are rotatable<br />

for horizontal or vertical operation. Built-in pneumatic load <strong>com</strong>pensation<br />

ensures that nominal displacement is automatically<br />

Vibration Systems<br />

achieved even for heavy <strong>test</strong> loads. Vibration<br />

transfer to the floor can be reduced with a<br />

swivel-frame (RIT) which has <strong>vibration</strong> isolators<br />

as a standard feature. The generator is cooled<br />

by a maintenance-free fan, with cooling air<br />

entering through a filter assembly.<br />

TIRA's “AIT“ system - built into the frame - provides<br />

integrated <strong>vibration</strong> isolation for vertical<br />

and horizontal body operation. The AIT system<br />

ensures optimal <strong>vibration</strong> isolation at low<br />

frequencies and precisely guides the generator<br />

body in the direction of excitation. Low Base<br />

“LB” generators are available with <strong>vibration</strong><br />

dampers or rail <strong>systems</strong> for better mobility.<br />

TIRA <strong>vibration</strong> generators, amplifiers and<br />

<strong>vibration</strong> control <strong>systems</strong> form a <strong>com</strong>plete <strong>test</strong><br />

system to document product quality in conformity<br />

with international standards (such as DIN,<br />

ISO, BS, MIL, IEC, ASTM).<br />

System TV 59327/*-340 TV 59327/*-440 TV 59327/*-640<br />

Shaker S596/*-640 S596/*-640 S596/*-640<br />

Amplifier A 54336 A 54336 A 54336<br />

Blower HRD 7/FU/11 HRD 7/FU/11 HRD 7/FU/11<br />

Metric American Metric American Metric American<br />

Rated peak force (N)/(lbf) Sine/Random/Shock 26700/26700/53400 6002/6002/12005 26700/26700/53400 6002/6002/12005 26700/26700/53400 6002/6002/12005<br />

Frequency range (Hz) DC - 3000 DC - 3000 DC - 3000 DC - 3000 DC - 2000 DC - 2000<br />

Max. rated travel (mm)/(inch) Pk - Pk 50.8 2.0 50.8 2.0 50.8 2.0<br />

Max. velocity (m/s)/(inch/sec) Sine/Random/Shock 1.8/1.8/2.5 71/71/98 1.8/1.8/2.5 71/71/98 1.8/1.8/2.5 71/71/98<br />

Max. acceleration (g) Sine/Random/Shock 84/84/167 84/84/167 79/79/158 79/79/158 66/66/131 66/66/131<br />

Rated current (A) 330 330 330 330 330 330<br />

Nominal impedance (Ohm) 0.3 0.3 0.3 0.3 0.3 0.3<br />

Suspension Stiffness (N/mm) (lbf/inch) 150 856.5 150 856.5 150 856.5<br />

Effective moving mass (kg)/(lb) 32.5 71.7 34.5 76.1 41.5 91.5<br />

Max. weight <strong>test</strong>ed (kg)/(lb) 610 1345 610 1345 610 1345<br />

Main resonance frequency (Hz) >2400 >2400 >2400 >2400 >2000 >2000<br />

Weight with trunnion (kg)/(lb) RIT/AIT/LB 2650/2880/2300 5842/6349/5071 2650/2880/2300 5842/6349/5071 2650/2880/2300 5842/6349/5071<br />

Stray magnetic field (mT) without/with degauss kit