31007166.00<br />

<strong>ConneXium</strong><br />

<strong>TSXETG100</strong><br />

<strong>Ethernet</strong> <strong>Gateway</strong><br />

<strong>Serial</strong> <strong>Connection</strong> <strong>Cases</strong><br />

2/2006


Overview<br />

What's in this<br />

Chapter?<br />

<strong>Connection</strong> <strong>Cases</strong><br />

31007166.00 2/2006 3<br />

1<br />

This document describes the wiring for the ETG100 to other devices’ serial port.<br />

This chapter contains the following topics:<br />

Topic Page<br />

ETG100 Wiring To Other Devices’ <strong>Serial</strong> Ports (RS232/RS485) 4<br />

ETG100 <strong>Serial</strong> Wiring 5<br />

Quantum/Momentum/Compact PLC - RS232 (RJ45) 7<br />

Quantum/Compact/ 984 - RS232 (DB9) 8<br />

Quantum/Momentum - RS485 (RJ45) 9<br />

Momentum - RS485 (Daisy Chain Cabling) 10<br />

Micro/Twido - RS485 (Mini-DIN) 11<br />

Premium (TSXSCY21601) - RS485 (DB25) 12<br />

Premium (TSXSCP114) - RS485 (PCMCIA) 13<br />

Premium (TSXSCP111) - RS232 (PCMCIA) 14


<strong>Connection</strong> <strong>Cases</strong><br />

ETG100 Wiring To Other Devices’ <strong>Serial</strong> Ports (RS232/RS485)<br />

Seven <strong>Cases</strong><br />

Case PLC Type Communication Protocol Port Type<br />

1 Quantum Unity High end<br />

Momentum<br />

Momentum option adapter<br />

Compact<br />

RS232 RJ45/female<br />

2 Quantum<br />

Compact<br />

984<br />

RS232 DB9/female<br />

3 Quantum Unity High end<br />

Momentum option adapter<br />

RS485 RJ45/female<br />

4 Momentum RS485 RJ45/female, daisy<br />

Momentum option adapter<br />

chain<br />

5 Twido<br />

Micro<br />

RS485 Mini-DIN/female<br />

6a Premium (TSX SCY 21601) RS485 DB25/female<br />

6b Premium (TSX SCP 114) RS485 PCMCIA<br />

7 Premium (TSX SCP 111) RS232 PCMCIA<br />

4 31007166.00 2/2006


ETG100 <strong>Serial</strong> Wiring<br />

<strong>Connection</strong> <strong>Cases</strong><br />

RS232 <strong>Serial</strong> Port The RS232 port is used to configure the ETG network parameters and for serial<br />

communication over Modbus. The ETG RS232 port is wired as a data terminal<br />

equipment (DTE) device and uses a standard RJ45 connector. An RJ45-to-DB9<br />

adapter and an <strong>Ethernet</strong> cross-over cable are included in the TCSEAK0100<br />

configuration kit (sold separately). Here are the pin assignments, in accordance with<br />

EIA/TIA-561 for RJ45:<br />

Pin Description<br />

1 Data Set Ready<br />

2 Received Line Signal Detector (data Carrier DSelect)<br />

3 Data Terminal Ready<br />

4 Signal Ground<br />

5 Received Data<br />

6 Transmit Data<br />

7 Clear to Send<br />

8 Request to send<br />

RS485 Wiring Here is a wiring diagram for 4-wire devices:<br />

120 Ω<br />

Termination<br />

Belden 8723 or 9842<br />

ETG100 Slave 1 Slave 2 Slave 3<br />

Green (1) Tx+ (TXD1)<br />

Rx+<br />

Rx+<br />

Rx+<br />

White (2) Tx- (TXD0)<br />

Rx-<br />

Rx-<br />

Rx-<br />

Red (3) Rx+ (RXD1) Tx+<br />

Tx+<br />

Tx+<br />

Black (4) Rx- (RXD0)<br />

Tx-<br />

Tx-<br />

Tx-<br />

Shield (5)<br />

The color code shown is for Belden8723. The color code for Belden 9842 is Blue/<br />

White (Tx+), White/Blue Tx-), Orange/White (Rx+), and White/Orange (Rx-).<br />

Note: For surge protection, we recommend connecting the shield wire directly to<br />

an external earth ground at a single point.<br />

31007166.00 2/2006 5


<strong>Connection</strong> <strong>Cases</strong><br />

RS485 Biasing<br />

and Termination<br />

Here is a wiring diagram for 2-wire devices:<br />

120 Ω<br />

Termination<br />

ETG100<br />

Belden 9841<br />

Slave 1 Slave 2 Slave 3<br />

Blue (3) Rx+ (D1)<br />

L+<br />

L+<br />

L+<br />

White (4) Rx- (D0)<br />

L-<br />

L-<br />

L-<br />

Shield (5)<br />

The following DIP switch settings are recommended for 4-wire and 2-wire<br />

daisy chains:<br />

On<br />

Off<br />

Tx Rx Rx- Rx+ - +<br />

1 2 3 4 5 6<br />

Termination<br />

Bias<br />

Jumper (2-wire)<br />

6 31007166.00 2/2006<br />

4-wire<br />

2-wire<br />

Up/On Down/Off


Quantum/Momentum/Compact PLC - RS232 (RJ45)<br />

Case 1<br />

<strong>TSXETG100</strong><br />

ETG100<br />

RJ5 (female)<br />

Desc Pin<br />

DSR 1<br />

DCD 2<br />

DTR 3<br />

GND 4<br />

RxD 5<br />

TxD 6<br />

CTS 7<br />

RTS 8<br />

RJ5 (male)<br />

Pin<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Shield<br />

RJ5 (male)<br />

<strong>Connection</strong> <strong>Cases</strong><br />

Quantum Unity<br />

High End PLC<br />

Momentum Comm<br />

Option Adapter<br />

31007166.00 2/2006 7<br />

Pin<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Connector<br />

Case<br />

PLC Port<br />

RJ5 (female)<br />

Pin Desc<br />

1 DTR<br />

2 DSR<br />

3 TxD<br />

4 RxD<br />

5 GND<br />

6 RTS<br />

7 CTS<br />

8<br />

9<br />

Momentum PLC<br />

Compact PLC


<strong>Connection</strong> <strong>Cases</strong><br />

Quantum/Compact/ 984 - RS232 (DB9)<br />

Case 2<br />

<strong>TSXETG100</strong><br />

ETG100<br />

RJ5 (female)<br />

Desc Pin<br />

DSR 1<br />

DCD 2<br />

DTR 3<br />

GND 4<br />

RxD 5<br />

TxD 6<br />

CTS 7<br />

RTS 8<br />

RJ5<br />

(male)<br />

Pin<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Crossed cable<br />

TCSEAK0100 (config. kit)<br />

RJ5 RJ5<br />

(male) (female)<br />

Pin Pin<br />

1 1<br />

2 2<br />

3 3<br />

4 4<br />

5 5<br />

6 6<br />

7 7<br />

8 8<br />

RJ45/DB9<br />

Adapter<br />

DB9<br />

(female)<br />

Pin<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

PLC Port<br />

DB9 (female)<br />

Pin Desc<br />

1 DCD<br />

2 RxD<br />

3 TxD<br />

4 DTR<br />

5 GND<br />

6 DSR<br />

7 RTS<br />

8 CTS<br />

9 RI<br />

8 31007166.00 2/2006<br />

7<br />

8<br />

9<br />

Gender<br />

Charger<br />

male/male<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Quantum<br />

PLC<br />

Compact<br />

PLC<br />

984 PLC


Quantum/Momentum - RS485 (RJ45)<br />

Case 3<br />

Desc<br />

Tx+<br />

Tx-<br />

Rx+<br />

Rx-<br />

Shield<br />

Desc<br />

Rx+ (Tx+)<br />

Rx- (Tx-)<br />

Shield<br />

<strong>TSXETG100</strong><br />

ETG100<br />

Screws (4 wires)<br />

Pin#<br />

1<br />

2<br />

3<br />

4<br />

5<br />

ETG100<br />

Screws (2 wires)<br />

Pin#<br />

3<br />

4<br />

5<br />

TWDXCAFJ010<br />

(Pigtail to RJ45)<br />

Pig-tail<br />

Cable color<br />

Green<br />

Green-White<br />

Orange-White<br />

Orange<br />

Brown<br />

Cable color<br />

Green<br />

Green-White<br />

Orange-White<br />

Orange<br />

Brown<br />

RJ45<br />

(male)<br />

Pin#<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Pin#<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

<strong>Connection</strong> <strong>Cases</strong><br />

Quantum Unity<br />

High End PLC<br />

Momentum Comm<br />

Option Adapters<br />

PLC port<br />

RJ45 (female)<br />

Pin# Desc<br />

1 Rx-<br />

2 Rx+<br />

3 Tx+<br />

4 Reserved<br />

5 GND<br />

6 Tx-<br />

7 Reserved<br />

8 Shield<br />

31007166.00 2/2006 9


<strong>Connection</strong> <strong>Cases</strong><br />

Momentum - RS485 (Daisy Chain Cabling)<br />

Case 4<br />

<strong>TSXETG100</strong><br />

ETG100<br />

Screws (4 wires)<br />

Desc<br />

Tx+<br />

Tx-<br />

Rx+<br />

Rx-<br />

Shield<br />

Desc<br />

Rx+ (Tx+)<br />

Pin#<br />

1<br />

2<br />

3<br />

4<br />

5<br />

ETG100<br />

Screws (2 wires)<br />

Pin#<br />

3<br />

Rx-(Tx-) 4<br />

Shield 5<br />

Pigtail<br />

Cable color<br />

Green<br />

Green-White<br />

Orange-White<br />

Orange<br />

Brown<br />

Cable color<br />

Green<br />

Green-White<br />

Orange-White<br />

Orange<br />

TWDXCAFJ010<br />

(Pigtail to RJ45)<br />

RJ45<br />

(male)<br />

4 wires<br />

Momentum PLC Momentum PLC<br />

+ Option Adapter<br />

2 wires<br />

Momentum PLC Momentum PLC<br />

Brown<br />

1 170 XTS 021 00 Terminating resistor plug, color code red<br />

2 170 XTS 040 00 Modbus RS485 connector T (DB9 base)<br />

3 170 MCI 02010 Modbus Plus/Modbus RS485 Short Interconnect cable, color code black.<br />

4 170 XTS 041 00 Modbus RS485 connector T (RJ45 base)<br />

5 170 XTS 042 00 Terminating shunt plug, color code blue<br />

Note: See the Momentum M1 Processor Adapter and Option Adapter User Guide<br />

(870 USE 101) for additional detail on this wiring.<br />

10 31007166.00 2/2006<br />

Pin#<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

(2)<br />

(3) (4) (1)<br />

(3) (4) (5)<br />

(2)


Micro/Twido - RS485 (Mini-DIN)<br />

Case 5<br />

<strong>TSXETG100</strong><br />

ETG100<br />

Screws (2 wires)<br />

Desc<br />

Rx+<br />

Rx-<br />

Shield<br />

Pin#<br />

3<br />

4<br />

5<br />

TWDXCAFD010<br />

(Pigtail to mini-DIN)<br />

Pig-tail<br />

Cable color<br />

Black<br />

Green<br />

Shell<br />

Mini-DIN<br />

(male)<br />

Pin#<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

Shell<br />

<strong>Connection</strong> <strong>Cases</strong><br />

Twido<br />

PLC<br />

Mini-DIN<br />

(female)<br />

Pin# Desc.<br />

1 D1(A+)RxD+<br />

2 D0(B-)RxD-<br />

3 n/c<br />

4 /DE<br />

5 /DPT<br />

6 n/c<br />

7 Common<br />

8 5 Volts<br />

Shell Shield<br />

TSX37<br />

Micro PLC<br />

31007166.00 2/2006 11


<strong>Connection</strong> <strong>Cases</strong><br />

Premium (TSXSCY21601) - RS485 (DB25)<br />

Case 6a<br />

<strong>TSXETG100</strong><br />

ETG100<br />

Screws (2 wires)<br />

Desc<br />

Rx+<br />

Rx-<br />

Shield<br />

Pin#<br />

3<br />

4<br />

5<br />

Pigtail<br />

Color<br />

White/Orange<br />

Orange/White<br />

TSXSCYCM6030<br />

(Pigtail to DB25)<br />

DB25<br />

(male)<br />

Pin#<br />

1<br />

2<br />

Premium PLC<br />

TSXSCY21601<br />

or TSXSCY11601<br />

DB25<br />

(female)<br />

Pin# Desc<br />

1<br />

2<br />

12 31007166.00 2/2006<br />

5<br />

6<br />

24<br />

25<br />

5<br />

6 EMI-<br />

24<br />

25<br />

EMI+


Premium (TSXSCP114) - RS485 (PCMCIA)<br />

Case 6b<br />

<strong>TSXETG100</strong><br />

ETG100<br />

Screws (2 wires)<br />

Desc<br />

Rx+<br />

Rx-<br />

Shield<br />

Pin#<br />

3<br />

4<br />

5<br />

TSXSCPCM4030<br />

(Pigtail to PCMCIA)<br />

Pigtail<br />

Color<br />

White/Green<br />

Green/White<br />

<strong>Connection</strong> <strong>Cases</strong><br />

Premium PLC<br />

TSXSCY21601<br />

or TSXSCY11601<br />

PCMCIA PCMCIA<br />

31007166.00 2/2006 13


<strong>Connection</strong> <strong>Cases</strong><br />

Premium (TSXSCP111) - RS232 (PCMCIA)<br />

Case 7<br />

<strong>TSXETG100</strong><br />

ETG100<br />

RJ5 (female)<br />

Desc Pin<br />

DSR<br />

DCD<br />

DTR<br />

GND<br />

RxD<br />

TxD<br />

CTS<br />

RTS<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

RJ45<br />

(male)<br />

Pin<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

DB25<br />

(female)<br />

Pin<br />

TSXSCPCC1030<br />

(DB25 to PCMCIA)<br />

Premium PLC or<br />

TSXSCY21601<br />

and TSXSCP1111<br />

14 31007166.00 2/2006<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

20<br />

25<br />

DB25<br />

(male)<br />

Pin Desc<br />

1 Shield<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

TxD<br />

RxD<br />

RTS<br />

CTS<br />

DSR<br />

GND<br />

DCD<br />

20 DTR<br />

25<br />

PCMCIA PCMCIA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!