set ® <strong>45</strong> anD set ® <strong>45</strong> <strong>HW</strong><br />

Chemical-action repair mortar<br />

Application<br />

1. Immediately place the mixture onto<br />

the properly prepared substrate. Work<br />

the material firmly into the bottom<br />

and sides of the patch to ensure good<br />

bond.<br />

2. Level the Set® <strong>45</strong> and screed to<br />

the elevation of the existing concrete.<br />

Minimal finishing is required. Match<br />

the existing concrete texture.<br />

Curing<br />

No curing is required, but protect from<br />

rain immediately after placing. Liquidmembrane<br />

curing compounds or plastic<br />

sheeting may be used to protect the<br />

early surface from precipitation, but<br />

never wet cure Set® <strong>45</strong>.<br />

For Best Performance<br />

• Color variations are not indicators of<br />

abnormal product performance.<br />

• Regular Set® <strong>45</strong> will not freeze at<br />

temperatures above -20° F (-29° C)<br />

when appropriate precautions are<br />

taken.<br />

• Do not add sand, fine aggregate, or<br />

Portland cement to Set® <strong>45</strong>.<br />

• Do not use Set® <strong>45</strong> for patches less<br />

than 1/2” (13 mm) deep. For deep<br />

patches, use Set® <strong>45</strong> Hot Weather<br />

formula extended with aggregate,<br />

regardless of the temperature. Consult<br />

your Degussa representative for<br />

further instructions.<br />

• Do not use limestone aggregate.<br />

• Water content is critical. Do not<br />

deviate from the recommended water<br />

content printed on the bag.<br />

• Precondition these materials to approximately<br />

70° F (21° C) for 24 hours<br />

before using.<br />

6-42<br />

• Protect repairs from direct sunlight,<br />

wind, and other conditions that could<br />

cause rapid drying of material.<br />

• When mixing or placing Set® <strong>45</strong> in a<br />

closed area, provide adequate ventilation.<br />

• Do not use Set® <strong>45</strong> as a precision<br />

nonshrink grout.<br />

• Never featheredge Set® <strong>45</strong>; for best<br />

results, always sawcut the edges of a<br />

patch.<br />

• Prevent any moisture loss during the<br />

first 3 hours after placement. Protect<br />

Set® <strong>45</strong> with plastic sheeting or a<br />

curing compound in rapidevaporation<br />

conditions.<br />

• Do not wet cure.<br />

• Do not place Set® <strong>45</strong> on a hot (90° F<br />

[32° C]), dry substrate.<br />

• When using Set® <strong>45</strong> in contact with<br />

galvanized steel or aluminum, consult<br />

your local Degussa sales representative.<br />

• Make certain the most current versions<br />

of product data sheet and MSDS<br />

are being used; call Customer Service<br />

(1-800-433-9517) to verify the most<br />

current versions.<br />

• Proper application is the responsibility<br />

of the user. Field visits by Degussa<br />

personnel are for the purpose of making<br />

technical recommendations only<br />

and not for supervising or providing<br />

quality control on the jobsite.<br />

Health and Safety<br />

Caution<br />

Risks<br />

Eye irritant. Skin irritant. Lung irritant.<br />

May cause delayed lung injury.<br />

Precautions<br />

KEEP OUT OF THE REACH OF<br />

CHILDREN. Avoid contact with eyes.<br />

Wear suitable protective eyewear.<br />

Avoid prolonged or repeated contact<br />

with skin. Wear suitable gloves. Wear<br />

suitable protective clothing. Do not<br />

breathe dust. In case of insufficient<br />

ventilation, wear suitable respiratory<br />

equipment. Wash soiled clothing<br />

before reuse.<br />

First Aid<br />

Wash exposed skin with soap and<br />

water. Flush eyes with large quantities<br />

of water. If breathing is difficult, move<br />

person to fresh air.<br />

Waste Disposal Method<br />

This product when discarded or disposed<br />

of is not listed as a hazardous<br />

waste in federal regulations. Dispose<br />

of in a landfill in accordance with local<br />

regulations. For additional information<br />

on personal protective equipment,<br />

first aid, and emergency procedures,<br />

refer to the product Material Safety<br />

Data Sheet (MSDS) on the job site or<br />

contact the company at the address or<br />

phone numbers given below.<br />

Proposition 65<br />

This product contains materials listed<br />

by the state of California as known to<br />

cause cancer, birth defects, or reproductive<br />

harm.<br />

VOC Content<br />

0 lbs/gal or 0 g/L.<br />

For medical emergencies only,<br />

call ChemTrec (1-800-424-9300).<br />

LIMITED WARRANTY NOTICE Every reasonable effort is made to apply Degussa exacting standards both in the manufacture of our products and in the information which we issue concerning these products and their use. We warrant our products to be of good quality and will replace or, at our election,<br />

refund the purchase price of any products proved defective. Satisfactory results depend not only upon quality products, but also upon many factors beyond our control. Therefore, except for such replacement or refund, Degussa MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING<br />

WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, RESPECTING ITS PRODUCTS, and Degussa shall have no other liability with respect thereto. Any claim regarding product defect must be received in writing within one (1) year from the date of shipment. No claim will<br />

be considered without such written notice or after the specified time interval. User shall determine the suitability of the products for the intended use and assume all risks and liability in connection therewith. Any authorized change in the printed recommendations concerning the use of our products must bear<br />

the signature of the Degussa Technical Manager. This information and all further technical advice are based on Degussa’s present knowledge and experience. However, Degussa assumes no liability for providing such information and advice including the extent to which such information and advice may relate<br />

to existing third party intellectual property rights, especially patent rights. In particular, Degussa disclaims all WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. DEGUSSA SHALL NOT BE<br />

RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. Degussa reserves the right to make any changes according to technological progress or further developments. It is the customer’s responsibility and obligation to carefully<br />

inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither<br />

a recommendation, nor an endorsement of any product and does not imply that similar products could not be used.<br />

For Your DOT Product Specialist, Call: 800.936.6626


locksHear<br />

Bolt systeM<br />

Dayton/Richmond Bar-Lock Coupler System*<br />

ICC Evaluation Report No. 5064<br />

The Dayton/Richmond Bar-Lock Coupler System provides a simple, quick, cost effective method for splicing rebar in tension<br />

and/or compression applications.<br />

Bar-Lock couplers may be used with plain or deformed bars in sizes #4 through #18. Bar-Lock couplers utilize lock-shear<br />

bolts and special grip rails to mechanically splice with the rebar. The serrated grip rails cradle the rebar and are embedded<br />

in the rebar as the lock-shear bolts are tightened. The heads of the lock-shear bolts are designed to shear off at a prescribed<br />

torque in order to accomplish proper installation.<br />

System Advantages:<br />

• Quick and easy to install – saves time and money.<br />

• Eliminates bar threading and/or special bar end treatment.<br />

• No special installation equipment required.<br />

• High strength in tension, compression and seismic applications.<br />

• Available in standard, transition and weldable versions in #4 through #18 sizes.<br />

• Ideal for new construction and rehab projects.<br />

System Compliance<br />

Bar-Lock couplers are test-certified to exceed the requirements of, are pre-qualified<br />

and approved, or recognized by the following building approval agencies:<br />

• State Departments of Transportation<br />

• International Conference of Building Officials (ICC)<br />

• Building Officials and Code Administrators (BOCA)<br />

• Southern Building Code Congress International (SBCCI)<br />

• American Concrete Institute (ACI)<br />

• Concrete Reinforcing Steel Institute (CRSI)<br />

• City of Los Angeles Department of Building and Safety<br />

Bar-Lock coupler source material is fabricated under ISO9000 quality standards.<br />

Bar-Lock couplers are tested by independent, certified testing laboratories in four<br />

modes of testing: tension, compression, fatigue and cyclic. All tests are done to the<br />

requirements of ICC and/or Caltrans requirements utilizing ASTM A615 grade 60<br />

rebar material. Copies of test reports are available on request.<br />

Typical Specification<br />

By specific name:<br />

• Bar-Lock Mechanical Coupler System manufactured by Dayton/Richmond Concrete<br />

Accessories.<br />

By generic description:<br />

• Mechanical butt splices utilizing lock-shear bolts and internal serrated grip rails<br />

within the coupling sleeve. They shall exceed the specification requirements for<br />

both tension and compression specified by ACI 318 and the Uniform Building code,<br />

and be recognized by the International Conference of Building Officials (ICC).<br />

For Your DOT Product Specialist, Call: 800.936.6626<br />

6-43


locksHear<br />

Bolt systeM<br />

D-250 Bar-Lock S/CA-Series Couplers<br />

The D-250 Bar-Lock S/CA-Series Couplers are designed for use in<br />

most tension and compression applications. They are available in<br />

rebar sizes #4 through #18 and exceed 135% of specified yield of<br />

Grade 60 rebar. S/CA couplers are an approved Caltrans “Service”<br />

splice and are recognized by ICC, ACI and most State departments<br />

of Transportation. S/CA couplers are available in transition sizes,<br />

weldable half couplers and epoxy coated.<br />

Coupler<br />

Designation Coupler<br />

Designation<br />

4S/CA<br />

4S/CA<br />

5S/CA<br />

5S/CA<br />

6S/CA<br />

6S/CA<br />

7S/CA<br />

7S/CA<br />

8S/CA<br />

8S/CA<br />

9S/CA<br />

9S/CA<br />

10S/CA<br />

10S/CA<br />

11S/CA<br />

11S/CA<br />

14S/CA<br />

14S/CA<br />

18S/CA<br />

18S/CA<br />

For Use<br />

For Use<br />

Barrel<br />

On Rebar Barrel<br />

On Rebar<br />

Stamp<br />

Size Stamp<br />

Size<br />

Identification<br />

(in./mm.) Identification<br />

(in./mm.)<br />

#4–13M 4S...CA<br />

#4–13M 4S...CA<br />

#5–16M 5S...CA<br />

#5–16M 5S...CA<br />

#6–19M 6S...CA<br />

#6–19M 6S...CA<br />

#7–22M 7S...CA<br />

#7–22M 7S...CA<br />

#8–25M 8S...CA<br />

#8–25M 8S...CA<br />

#9–29M 9S...CA<br />

#9–29M 9S...CA<br />

#10–32M 10S...CA<br />

#10–32M 10S...CA<br />

#11–36M 11S...CA<br />

#11–36M 11S...CA<br />

#14–43M 14S...CA<br />

#14–43M 14S...CA<br />

#18–57M 18S...CA<br />

#18–57M 18S...CA<br />

D-250 Bar-Lock S/CA-Series Couplers<br />

D-250 Bar-Lock S/CA-Series Couplers<br />

Tube Specifications Bolt Specifications<br />

Tube Specifications Bolt Specifications<br />

Outside<br />

Head Nominal<br />

Diameter Outside Length Weight Bolt Head Size Nominal Shear<br />

Diameter Length Weight Bolt<br />

(in.) (in.) (lbs.) Qty. Size (in.) Torque* Shear<br />

(in.) (in.) (lbs.) Qty. (in.) Torque*<br />

1.3 3.9 1.0 2 0.5 40<br />

1.3 3.9 1.0 2 0.5 40<br />

1.7 4.5 1.8 2 0.5 80<br />

1.7 4.5 1.8 2 0.5 80<br />

1.9 6.3 3.5 3 0.5 80<br />

1.9 6.3 3.5 3 0.5 80<br />

1.9 8.0 4.1 4 0.5 80<br />

1.9 8.0 4.1 4 0.5 80<br />

2.2 10.2 7.6 4 0.625 180<br />

2.2 10.2 7.6 4 0.625 180<br />

2.9 9.0 11.4 3 0.75 280<br />

2.9 9.0 11.4 3 0.75 280<br />

2.9 11.5 15.5 4 0.75 350<br />

2.9 11.5 15.5 4 0.75 350<br />

3.1 14.0 20.5 5 0.75 350<br />

3.1 14.0 20.5 5 0.75 350<br />

3.5 16.5 26.0 6 0.75 350<br />

3.5 16.5 26.0 6 0.75 350<br />

4.3 27.1 60.0 10 0.75 475<br />

4.3 27.1 60.0 10 0.75 475<br />

D-250 Bar-Lock L-Series Couplers<br />

The D-250 Bar-Lock L-Series Coupler is similar to the<br />

Standard Coupler but is designed for use when higher<br />

loads are required, such as extreme tension/compression<br />

application and/or seismic loading conditions. L-Series<br />

couplers are available in rebar sizes #4 through #14 and<br />

exceed 160% of specified yield of Grade 60 rebar. L-Series<br />

couplers are approved for use by most state DOTs,<br />

are recognized as an ICC Type 2 seismic splice, and meet<br />

ACT specifications. L-Series couplers are also available in<br />

transition sizes, weldable half couplers and epoxy coated.<br />

Coupler<br />

Designation Coupler<br />

Designation<br />

4L<br />

4L<br />

5L<br />

5L<br />

6L<br />

6L<br />

7L<br />

7L<br />

8L<br />

8L<br />

9L<br />

9L<br />

10L<br />

10L<br />

11L<br />

11L<br />

14L<br />

14L<br />

For Use<br />

For Use<br />

Barrel<br />

On Rebar Barrel<br />

On Rebar<br />

Stamp<br />

Size Stamp<br />

Size<br />

Identification<br />

(in./mm.) Identification<br />

(in./mm.)<br />

#4–13M 4L...<br />

#4–13M 4L...<br />

#5–16M 5L...<br />

#5–16M 5L...<br />

#6–19M 6L...<br />

#6–19M 6L...<br />

#7–22M 7L...<br />

#7–22M 7L...<br />

#8–25M 8L...<br />

#8–25M 8L...<br />

#9–29M 9L...<br />

#9–29M 9L...<br />

#10–32M 10L...<br />

#10–32M 10L...<br />

#11–36M 11L...<br />

#11–36M 11L...<br />

#14–43M 14L...<br />

#14–43M 14L...<br />

D-250 Bar-Lock L-Series Couplers<br />

D-250 Bar-Lock L-Series Couplers<br />

Tube Specifications Bolt Specifications<br />

Tube Specifications Bolt Specifications<br />

Outside<br />

Head Nominal<br />

Diameter Outside Length Weight Bolt Head Size Nominal Shear<br />

Diameter Length Weight Bolt<br />

(in.) (in.) (lbs.) Qty. Size (in.) Torque* Shear<br />

(in.) (in.) (lbs.) Qty. (in.) Torque*<br />

1.3 5.5 1.6 3 0.5 40<br />

1.3 5.5 1.6 3 0.5 40<br />

1.7 6.3 2.8 3 0.5 80<br />

1.7 6.3 2.8 3 0.5 80<br />

1.9 8.0 4.5 4 0.5 80<br />

1.9 8.0 4.5 4 0.5 80<br />

1.9 9.8 5.5 5 0.5 80<br />

1.9 9.8 5.5 5 0.5 80<br />

2.2 12.3 9.5 5 0.625 180<br />

2.2 12.3 9.5 5 0.625 180<br />

2.9 11.5 15.5 4 0.75 280<br />

2.9 11.5 15.5 4 0.75 280<br />

2.9 14.0 19.5 5 0.75 410<br />

2.9 14.0 19.5 5 0.75 410<br />

3.1 16.5 24.0 6 0.75 410<br />

3.1 16.5 24.0 6 0.75 410<br />

3.5 19.1 32.0 7 0.75 410<br />

3.5 19.1 32.0 7 0.75 410<br />

*Foot pounds.<br />

6-44<br />

D-250 Bar-Lock<br />

S/CA-Series oupler<br />

Min.<br />

% Min. Fy<br />

% Fy<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

135<br />

D-250 Bar-Lock<br />

L-Series Coupler<br />

Min.<br />

% Min. Fy<br />

% Fy<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

160<br />

Meets or Exceeds<br />

Meets or Exceeds<br />

CAL<br />

TRANS CAL ICBO ICBO<br />

TRANS ICBO ICBO<br />

Service Type 1 Type 2<br />

Service Type 1 Type 2<br />

Meets or Exceeds<br />

Meets or Exceeds<br />

CAL<br />

TRANS CAL ICBO ICBO<br />

TRANS ICBO ICBO<br />

Service Type 1 Type 2<br />

Service Type 1 Type 2<br />

To Order:<br />

Specify: (1) quantity,<br />

(2) name, (3) coupler<br />

designation, (4) if epoxy<br />

coating is required.<br />

Example:<br />

300, D-250 Bar-Lock<br />

S/CA-Series Couplers,<br />

8S/CA.<br />

*Foot pounds.<br />

To Order:<br />

Specify: (1) quantity,<br />

(2) name, (3) coupler<br />

designation, (4) if epoxy<br />

coating is required.<br />

Example:<br />

100, D-250 Bar-Lock<br />

LSeries Couplers, 8L,<br />

epoxy coated.<br />