Filters and Filter Silencers - Universal
Filters and Filter Silencers - Universal
Filters and Filter Silencers - Universal
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
FRH Series<br />
<strong>Filter</strong><br />
FCRH Series<br />
<strong>Filter</strong>-Silencer<br />
A B C D<br />
B<br />
F<br />
C<br />
These products are similar to the FH <strong>and</strong><br />
FSH series, except that the FRH <strong>and</strong> FCRH<br />
series are two-stage filters. The second<br />
stage consists of a battery of 12 cartridge<br />
filters for each 20" 3 25" 3 2" prefilter.<br />
The high-efficiency P-5 cartridge filters have<br />
threaded ends that screw into individual<br />
receptacles. As each P-5 filter is removed<br />
<strong>and</strong> replaced, less than 4 in 2 is exposed<br />
to the flow of unfiltered air, so “hot<br />
swap” changeouts (while the system is in<br />
operation) are an option for these units.<br />
Usually, a moderately efficient filter panel is<br />
Model<br />
FRH-8-2<br />
FRH-10-2<br />
FRH-10-4<br />
FRH-12-4<br />
FRH-14-4<br />
FRH-14-8<br />
FRH-16-8<br />
FRH-18-8<br />
FRH-20-8<br />
FRH-20-12<br />
FRH-24-12<br />
FRH-24-16<br />
FRH-30-16<br />
FRH-30-24<br />
FRH-36-24<br />
A<br />
D<br />
E<br />
FRH <strong>Filter</strong><br />
Part Number<br />
Removable<br />
Weather Louver<br />
Part Numbers (St<strong>and</strong>ard Units with Louvers)<br />
38-308-AAL<br />
38-310-AAL<br />
38-510-AAL<br />
38-412-AAL<br />
38-314-AAL<br />
38-514-AAL<br />
38-416-AAL<br />
38-418-AAL<br />
38-320-AAL<br />
38-520-AAL<br />
38-424-AAL<br />
38-524-AAL<br />
38-330-AAL<br />
38-530-AAL<br />
38-336-AAL<br />
B<br />
F<br />
C<br />
FCRH <strong>Filter</strong> Silencer<br />
Model<br />
FCRH-8-2<br />
FCRH-10-2<br />
FCRH-10-4<br />
FCRH-12-4<br />
FCRH-14-4<br />
FCRH-14-8<br />
FCRH-16-8<br />
FCRH-18-8<br />
FCRH-20-8<br />
FCRH-20-12<br />
FCRH-24-12<br />
FCRH-24-16<br />
FCRH-30-16<br />
FCRH-30-24<br />
FCRH-36-24<br />
A<br />
D<br />
E<br />
used as the first-stage element. The FCRH<br />
series has an integrated silencing section<br />
that provides moderate noise reduction.<br />
All units are fabricated of steel sheet <strong>and</strong><br />
plate, welded throughout to provide a<br />
rugged, long-lasting, trouble-free air filtering<br />
component. All models are equipped with<br />
a pressure tap <strong>and</strong> flange drilled to match<br />
125/150-lb ANSI specifications. Inside <strong>and</strong><br />
outside surfaces are primed <strong>and</strong> given a<br />
finish coat of enamel paint. All housings<br />
come with low-profile, UV-stabilized highdensity<br />
polyethylene weather louvers.<br />
Part Number<br />
39-308-AAL<br />
39-310-AAL<br />
39-510-AAL<br />
39-412-AAL<br />
39-314-AAL<br />
39-514-AAL<br />
39-416-AAL<br />
39-418-AAL<br />
39-320-AAL<br />
39-520-AAL<br />
39-424-AAL<br />
39-524-AAL<br />
39-330-AAL<br />
39-530-AAL<br />
39-336AAL<br />
Removable<br />
Weather Louver<br />
Config.<br />
A<br />
A<br />
B<br />
B<br />
B<br />
C<br />
C<br />
C<br />
C<br />
D<br />
D<br />
C<br />
C<br />
D<br />
D<br />
Cap.<br />
CFM<br />
1,750<br />
2,750<br />
2,750<br />
4,000<br />
5,400<br />
5,400<br />
7,000<br />
8,900<br />
11,000<br />
11,000<br />
16,000<br />
16,000<br />
20,500<br />
20,500<br />
35,500<br />
A<br />
(nom.)<br />
8<br />
10<br />
10<br />
12<br />
14<br />
14<br />
16<br />
18<br />
20<br />
20<br />
24<br />
24<br />
30<br />
30<br />
36<br />
3<br />
For centrifugal compressors, blowers, engines,<br />
<strong>and</strong> gas turbines. For reciprocating compressors,<br />
ask <strong>Universal</strong> for recommendations.<br />
Noise Attenuation for FCRH<br />
Attenuation, dB<br />
B C D E F<br />
Weight<br />
FRH FCRH<br />
Number <strong>and</strong><br />
Size of <strong>Filter</strong><br />
Openings<br />
Final<br />
<strong><strong>Filter</strong>s</strong><br />
25.50 22.25 40.00 46.50 3.50 205 245 2, 2032532 24<br />
25.50 22.25 40.00 46.50 3.50 210 255 2, 2032532 24<br />
25.50 42.00 42.00 48.50 3.50 375 385 4, 2032532 48<br />
25.50 42.00 42.00 48.50 3.50 380 435 4, 2032532 48<br />
25.50 42.00 42.00 48.50 3.50 395 440 4, 2032532 48<br />
40.75 52.00 52.00 48.50 3.50 655 735 8, 2032532 96<br />
40.75 52.00 52.00 57.88 4.50 665 745 8, 2032532 96<br />
40.75 52.00 52.00 57.88 4.50 665 755 8, 2032532 96<br />
40.75 52.00 52.00 57.88 4.50 675 765 8, 2032532 96<br />
61.00 60.00 60.00 65.88 4.50 1,265 1,515 12, 2032532 144<br />
61.00 60.00 60.00 65.88 4.50 1,315 1,565 12, 2032532 144<br />
50.75 66.00 66.00 72.50 4.50 1,440 1,640 16, 2032532 192<br />
50.75 66.00 66.00 72.50 4.50 1,490 1,690 16, 2032532 192<br />
76.00 72.00 72.00 78.50 4.50 2,130 2,480 24, 2032532 288<br />
76.00 72.00 72.00 78.50 4.50 2,230 2,630 24, 2032532 288<br />
Nominal capacity is based on an exit velocity of approximately 5,000 ft/min. <strong>Filter</strong> element capacity may be greater, but this is unrelated to unit capacity.<br />
2”-deep filter frames will hold single or dual elements. Refer to page 8 for filter element details.<br />
B<br />
F<br />
C<br />
A<br />
D<br />
E<br />
Removable<br />
Weather Louver<br />
B<br />
F<br />
C<br />
2<br />
3<br />
4<br />
5<br />
8<br />
13<br />
14<br />
13<br />
A Removable<br />
Weather Louver<br />
D<br />
E<br />
Octave B<strong>and</strong> Center<br />
Frequency, Hz<br />
63<br />
125<br />
250<br />
500<br />
1,000<br />
2,000<br />
4,000<br />
8,000