1. DCAC DSP Data Line Checking<br />

After press the [TUNING MODE] button, DCAC Factory test<br />

mode will start, below display will show:<br />

“DCAC x” x = 1, 2, 3, 4<br />

If there is error happen, below display will show:<br />

“ERR SD0x” x = 1 → D1501 or R1530 problem<br />

x = 2 → D1502 problem<br />

x = 3 → D1503 problem<br />

x = 4 → D1504 problem<br />

2. DCAC board Checking<br />

Connect front left speaker of the receiver and AUTO CAL microphone.<br />

Turn [MASTER VOLUME] jog, there will be test tone<br />

sound output from front left speaker, and the display will change<br />

accordingly.<br />

“AD - xxx” xxx = 0 to 255 (depends on loudness of test tone)<br />

RE-BOX CLASSIFICATION TEST MODE<br />

Procedure:<br />

1. While pressing the [MEMORY/ENTER] and [INPUT MODE]<br />

buttons, press the [?/1] button to turn on the main power.<br />

2. The message “R.BOX[][][]XX” appears.<br />

XX: times set powered on<br />

VACS CONTROL TEST MODE<br />

The VACS feature of the amplifi er is turned off purposely.<br />

Procedure:<br />

1. While pressing the [MEMORY/ENTER] and [2CH] buttons,<br />

press the [?/1] button to turn on the main power.<br />

2. The message “VACS OFF” appears.<br />