DONATI SOLLEVAMENTI S.r.l. - Via Roma, 55 - 21020 Daverio (VA) - Tel. 0332 942611 - Fax. 0332 948597<br />

Every three months, verify the efficiency of the thrust block and its pinion:<br />

• Use the push-button panel to activate the arm’s “forward and reverse” movements, check<br />

that the thrust block and its pinion run smoothly, silently and regularly.<br />

• If necessary, in relation to the mode of operation and/or service location (e.g. intense<br />

operation, operation outdoors or under extreme heat, etc.), when conducting annual<br />

inspections, disassemble the gearmotor and verify the wear and lubrication of the teeth on<br />

the thrust block and reducer pinion. Lubricate with grease if necessary.<br />

Replace the pinion on the gearmotor and/or thrust block if the following<br />

occurs:<br />

• Strong variations in noise emissions from the gearmotor, and thrust block<br />

squeaking.<br />

• Excessive friction on the thrust block and/or strong vibrations from the<br />

gearmotor.<br />

• Difficult and/or irregular rotation of the arm resulting in “snaps” and/or<br />

"bursts".<br />

Every three months, verify the efficiency of the rotation motor brake:<br />

59<br />

TECNICO<br />

DONATI<br />

DONATI<br />

SERVICE<br />

• Check the stability of the arm on empty, and that of the mass being handled at full load, controlling<br />

that braking and stopping spaces for the arm in rotation are comprised between 50 and 100 cm,<br />

estimated with respect to the tip of the arm.<br />

• Where necessary, adjust the crane’s brake, as outlined under section 6.4.1 “Adjusting the rotation<br />

brake on the crane arm,” at page 62<br />

Replace the brake gasket when the arm encounters instability, even<br />

after having adjusted the brake.<br />

• IN THE CASE OF A MALFUNCTION:<br />

• It is forbidden to intervene on the jib crane’s rotation arm with corrective<br />

maintenance.<br />

• Any extraordinary maintenance operation on the crane’s rotation<br />

arm brake must be conducted by DONATI SOLLEVAMENTI S.r.l.<br />

technical service personnel or by technicians authorized by the<br />

manufacturer<br />

On a monthly basis, verify the efficiency of the crane’s rotation reducer:<br />

TECNICO<br />

DONATI<br />

DONATI<br />

SERVICE<br />

• Check that the noise emitted from the reducer does not vary in intensity. Vibrations or<br />

excessive noise reflect wear on the teeth, or a worn out bushing.<br />

• Make certain there are no lubrication leaks, and check the lubricator level at least every four<br />

years.<br />

WARNING:<br />

• The reducers are lubricated for life and do not require any maintenance,<br />

nor, with the exception of leaks, any filling of lubricant.<br />

IN THE CASE OF A MALFUNCTION:<br />

• It is forbidden to intervene on the rotation reducer with corrective<br />

maintenance.<br />

• Any extraordinary maintenance operation on the rotation reducer<br />

must be conducted by DONATI SOLLEVAMENTI S.r.l. technical<br />

service personnel or by technicians authorized by the manufacturer<br />

TECNICO<br />

DONATI<br />

DONATI<br />

SERVICE