Every three months, verify the efficiency of the thrust block and its pinion:<br />
• Use the push-button panel to activate the arm’s “forward and reverse” movements, check<br />
that the thrust block and its pinion run smoothly, silently and regularly.<br />
• If necessary, in relation to the mode of operation and/or service location (e.g. intense<br />
operation, operation outdoors or under extreme heat, etc.), when conducting annual<br />
inspections, disassemble the gearmotor and verify the wear and lubrication of the teeth on<br />
the thrust block and reducer pinion. Lubricate with grease if necessary.<br />
Replace the pinion on the gearmotor and/or thrust block if the following<br />
occurs:<br />
• Strong variations in noise emissions from the gearmotor, and thrust block<br />
squeaking.<br />
• Excessive friction on the thrust block and/or strong vibrations from the<br />
gearmotor.<br />
• Difficult and/or irregular rotation of the arm resulting in “snaps” and/or<br />
"bursts".<br />
Every three months, verify the efficiency of the rotation motor brake:<br />
59<br />
TECNICO<br />
DONATI<br />
DONATI<br />
SERVICE<br />
• Check the stability of the arm on empty, and that of the mass being handled at full load, controlling<br />
that braking and stopping spaces for the arm in rotation are comprised between 50 and 100 cm,<br />
estimated with respect to the tip of the arm.<br />
• Where necessary, adjust the crane’s brake, as outlined under section 6.4.1 “Adjusting the rotation<br />
brake on the crane arm,” at page 62<br />
Replace the brake gasket when the arm encounters instability, even<br />
after having adjusted the brake.<br />
• IN THE CASE OF A MALFUNCTION:<br />
• It is forbidden to intervene on the jib crane’s rotation arm with corrective<br />
maintenance.<br />
• Any extraordinary maintenance operation on the crane’s rotation<br />
arm brake must be conducted by DONATI SOLLEVAMENTI S.r.l.<br />
technical service personnel or by technicians authorized by the<br />
manufacturer<br />
On a monthly basis, verify the efficiency of the crane’s rotation reducer:<br />
TECNICO<br />
DONATI<br />
DONATI<br />
SERVICE<br />
• Check that the noise emitted from the reducer does not vary in intensity. Vibrations or<br />
excessive noise reflect wear on the teeth, or a worn out bushing.<br />
• Make certain there are no lubrication leaks, and check the lubricator level at least every four<br />
years.<br />
WARNING:<br />
• The reducers are lubricated for life and do not require any maintenance,<br />
nor, with the exception of leaks, any filling of lubricant.<br />
IN THE CASE OF A MALFUNCTION:<br />
• It is forbidden to intervene on the rotation reducer with corrective<br />
maintenance.<br />
• Any extraordinary maintenance operation on the rotation reducer<br />
must be conducted by DONATI SOLLEVAMENTI S.r.l. technical<br />
service personnel or by technicians authorized by the manufacturer<br />
TECNICO<br />
DONATI<br />
DONATI<br />
SERVICE