05.01.2013 Views

Mr Slim R22 Air Conditioning Range - Mitsubishi Electric Australia

Mr Slim R22 Air Conditioning Range - Mitsubishi Electric Australia

Mr Slim R22 Air Conditioning Range - Mitsubishi Electric Australia

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5<br />

Control function System configuration Features<br />

Necessary parts & equipment<br />

1.<br />

2.<br />

3.<br />

4.<br />

Group control<br />

with 1 remote<br />

controller<br />

Combined<br />

Remote/local<br />

control<br />

Operation with<br />

2 remote<br />

controllers<br />

Individual<br />

control from<br />

distant room<br />

5. Timer<br />

operation<br />

6.<br />

7.<br />

8.<br />

Operation by<br />

external signal<br />

Power failure<br />

automatic<br />

recovery<br />

Connection of<br />

remote display<br />

1<br />

Interface<br />

Interface<br />

Remote<br />

Controller Indoor Unit<br />

Distant<br />

Controller<br />

Panel<br />

Remote<br />

Controller<br />

<strong>Mr</strong>. SLIM New A/K Control System Configuration<br />

Distant<br />

Display<br />

PAC-SE55RA-E<br />

Timer Adapter<br />

Remote<br />

Controller<br />

Power<br />

Supply<br />

Remote<br />

Controller<br />

Remote<br />

Controller<br />

Outdoor Unit<br />

Relay<br />

Box Adapter<br />

Remote<br />

Controller<br />

Relay<br />

Box<br />

Indoor Unit<br />

Indoor Unit<br />

Adapter<br />

Indoor Unit<br />

Indoor Unit<br />

Indoor Unit<br />

■ Sequential start adaptable<br />

■ Same mode operation<br />

■ Maximum no. of units connectable per<br />

group: 16-refrigerant (Outdoor 16 sets)<br />

■ Simultaneous ON/OFF remote<br />

■ Operation can be switched between<br />

the distant controller panel and<br />

handheld controller<br />

■ 2 remote controllers can be connected<br />

to one group<br />

■ Control with the latest command<br />

■ Extension of remote controller cord<br />

(MAX. 500m)<br />

■ Weekly timer operation possible as<br />

standard (7 days-8 patterns)<br />

■ Optional adapter allows operation with<br />

timer sold on the market<br />

■ Static signal receivable<br />

■ Pulse signal receivable<br />

■ Returns to the state before power<br />

failure as standard<br />

■ Connectable to display panel in the<br />

field adapter<br />

MAC-397IF-E<br />

MA & Control Terminal Interface<br />

■ MAC-397IF-E<br />

(one for each outdoor unit)<br />

■ Timer adapter PAC-SE55RA-E<br />

(connect to CN32 on indoor circuit board)<br />

■ Relay box (on-site)<br />

■ Additional remote controller (option)<br />

■ Remote controller cord (on-site)<br />

—<br />

■ Timer adapter PAC-SE55RA-E<br />

(connect to CN32 on indoor circuit board)<br />

■ Timer adapter PAC-SE55RA-E<br />

(connect to CN32 on indoor circuit board)<br />

■ Multiple remote controller adpter<br />

PAC-725AD<br />

(connect to CN51 on indoor circuit board)<br />

■ Function setting by remote controller<br />

■ Multiple remote controller adpter<br />

PAC-725AD<br />

(connect to CN51 on indoor circuit board)<br />

■ Relay OMRON made LY-1 (DC12V)<br />

PAC-725AD<br />

Multiple Remote Controller Adapter<br />

(10 units of PAC-SA88HA-E)

Hooray! Your file is uploaded and ready to be published.