Electrical Control Valves<br />
6<br />
Electrical Control Valve Technology<br />
Thermostatic expansion valves and mechanical<br />
regulator valves have been used in the refrigeration<br />
and air conditioning industry to control superheat<br />
and refrigerant mass flow since its very beginning. As<br />
today’s systems require improved energy efficiency,<br />
tighter temperature control, wider range of operating<br />
conditions and incorporate new features like remote<br />
monitoring and diagnostics, the application of<br />
electronically operated valves becomes mandatory.<br />
Only they offer the controls performance necessary<br />
to meet these needs.<br />
Electrical control valves are actuators only. For<br />
operation in a system they need sensors, valve drivers<br />
and controllers, see next page.<br />
EX2 is designed for pulse width modulation and<br />
therefore able to provide a very precise temperature<br />
control. It is applicable to all common CFC, HCFC and<br />
HFC refrigerants and is used mainly for refrigeration<br />
applications such as display cases.<br />
The EX2 valve is a slide type solenoid valve with an<br />
orifice for expansion. It is either completely open or<br />
completely closed. One common valve body can be<br />
combined with 6 interchangeable orifices to cover 7<br />
capacity ranges.<br />
EX4/EX5/EX6/EX7/EX8 consist of two main internal<br />
assemblies, the valve and the stepper motor. The<br />
stepper motor is located next to the electrical<br />
plug and connected directly to the slide and cage<br />
assembly of the valve. Similar to the technology used<br />
in compressors, the motor is exposed to refrigerant<br />
and lubricant and the materials used are identical<br />
to the ones in compressor motors. The housing<br />
of the motor and valve assembly is made from<br />
stainless steel and fully hermetic, utilising exclusively<br />
brazing and welding technologies and eliminating<br />
all gaskets.<br />
This design offers several technical advantages such<br />
as proportional linear mass flow and a wide capacity<br />
range.<br />
A common feature of all ALCO electrical control valves<br />
is the low internal leakage rate which eliminates the<br />
need for additional solenoid valves.<br />
Valve Selection<br />
For EX2 the published table quotes capacities at 00%<br />
duty cycle. i.e. valve open continuously. However, it<br />
is recommended to operate the valve at partial load<br />
(50-80%) to allow for system load fluctuations.<br />
For EX4/EX5/EX6/EX7/EX8 all published capacities<br />
are maximum and there are no reserve capacities.<br />
Each valve should be selected at lowest possible<br />
operating condensing pressure. A larger size of valve<br />
leads to a shorter pull down period and a shorter<br />
travel time, i.e. faster respond. For example, EX7<br />
has maximum 5 seconds travel time. At 50% capacity<br />
operation the valve has only approximately 2.5<br />
seconds travel time.<br />
To facilate valve dimensioning for other than the<br />
standard conditions ALCO offers an Excel based<br />
Selection Tool. This can be ordered from all Copeland<br />
sales offices. See www.eCopeland.com for contact<br />
addresses, email or phone numbers.<br />
Selection Table for Electrical Control Valves and applicable Controllers<br />
Valve Function Capacity Feature Min. Main Application Applicable Controller<br />
Type Range kW Evaporating Page Page<br />
R407C Temperature °C<br />
EX<br />
Expansion<br />
Valve<br />
2.5 - 29.4<br />
Uni polar stepper<br />
motor driven<br />
-30<br />
Heat pumps,<br />
Air Conditioning<br />
refrigeration<br />
s. data<br />
sheet<br />
customized<br />
s. data<br />
sheet<br />
EX2<br />
EX4<br />
Exp. Valve 0,6 - 8,7 PWM -40 refrigeration 0 EC2 30<br />
EX5<br />
EX6<br />
EX7<br />
Expansion<br />
Valve<br />
5 - 53<br />
2 - 26<br />
35 - 347<br />
Bi polar stepper<br />
motor driven<br />
- 00<br />
- 00<br />
-50<br />
Heat pumps,<br />
Refrigeration, A/C,<br />
water chillers<br />
4 EC3-X3... Superheat Contr.<br />
EC3-3.. Cold room Contr.<br />
28<br />
33<br />
EX8 95 - 925 -50<br />
EX5 - 6<br />
EX6<br />
EX7<br />
Capacity<br />
Control<br />
3 - 37<br />
3 - 3<br />
Bi polar stepper<br />
motor driven<br />
Hot gas bypass<br />
regulator<br />
22 EXD-U.. Universal Contr. 29<br />
EX8 35 - 399<br />
EX6<br />
EX7<br />
EX8<br />
Capacity<br />
Control<br />
0.3 - 3.9<br />
- 4<br />
4 - 42<br />
Bi polar stepper<br />
motor driven<br />
-50<br />
Suction pressure<br />
regulator<br />
23 EXD-U.. Universal Contr. 29<br />
EX5 .5 - 8<br />
EX6<br />
EX7<br />
Liquid Mass<br />
Flow Control<br />
4 - 43<br />
5 - 53<br />
Bi polar stepper<br />
motor driven<br />
Condensing pressure<br />
regulator<br />
25 EXD-U.. Universal Contr. 29<br />
EX8 45 - 463<br />
EX5 5 - 53 - 00<br />
EX6<br />
EX7<br />
Liquid Level<br />
Control<br />
2 - 26<br />
35 - 347<br />
Bi polar stepper<br />
motor driven<br />
- 00<br />
-50<br />
Liquid level<br />
regulator<br />
25 EXD-U.. Universal Contr. 29<br />
EX8 95 - 925 -50<br />
A2.5. /0604/E