<strong>CS</strong>-<strong>RE9GKE</strong> /<strong>CU</strong>-<strong>RE9GKE</strong> /<strong>CS</strong>-<strong>RE12GKE</strong>/<strong>CU</strong>-<strong>RE12GKE</strong><br />

IndoorUnit<br />

Auto Switch<br />

Button<br />

PowerSwitch ON/OFF<br />

Whenthe remote controlcannotbe used or<br />

forrepairingandtesting,pleaseusethis<br />

button.<br />

Force Cooling Operation<br />

Keeppressingthisbutton for5secondsto start<br />

theforcecoolingoperation.<br />

Force HeatingOperation<br />

Keeppressing thisbutton for8secondsto start<br />

theforceheating operation.<br />

Different RemoteControlling Setting<br />

Keeppressing thisbutton for11 tochange<br />

differentremote controllingsetting(A B)<br />

Mode.<br />

Signal ReceivingSound<br />

Keeppressingthisbutton for16seconds to turn<br />

off orturnonthesignal receiving sound or<br />

H14Abnormality DetectionMode.<br />

OperationIndicationLamps<br />

Power(green)<br />

Timer(orange)<br />

<strong>Air</strong> quality<br />

Green<br />

OperationMode<br />

Orange<br />

Red<br />

Lightsupinoperation;<br />

BlinksduringHotStart<br />

operation and<br />

determiningAuto<br />

Operationmode<br />

Light up in Timer Setting.<br />

Blinks in Self Diagnosis Control<br />

Cooling/Heating/Soft Dry/Auto Operation<br />

4<br />

Feature mode<br />

Powerful<br />

Quiet<br />

Anti-freezingControl for the Evaporator<br />

CoolingorSoftDry Operation<br />

TimeDelaySafetyControl<br />

The unitwillrestartoperation in3-4<br />

minutesafter each pause.<br />

WarmBooting Control<br />

Indoor fanstarts runningwhenindoor<br />

piping temperature reaches19℃ orabove.<br />

IndoorFan SpeedControl<br />

High,Med+, Med, Med-,Low<br />

Auto Fan Speed<br />

<strong>Air</strong>flowDirection Control<br />

Automatic<strong>Air</strong>flowDirection Control<br />

Thelouver automaticallyswingsup anddown<br />

Five Manual<strong>Air</strong>flowDirection Control<br />

Delayed On-timer Control<br />

For coolingorsoft dry mode,theunit<br />

starts15minutesbeforethesettime with<br />

theremotecontrol,butfor heatingmode<br />

30minutes before thesettime.<br />

Automatic Restart Control<br />

Operationis restartedafter powerfailure<br />

at previous settingmode.