CS/CU-RE9GKE CS/CU-RE12GKE Air Conditioner
CS/CU-RE9GKE CS/CU-RE12GKE Air Conditioner
CS/CU-RE9GKE CS/CU-RE12GKE Air Conditioner
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CS</strong>-<strong>RE9GKE</strong> /<strong>CU</strong>-<strong>RE9GKE</strong> /<strong>CS</strong>-<strong>RE12GKE</strong>/<strong>CU</strong>-<strong>RE12GKE</strong><br />
IndoorUnit<br />
Auto Switch<br />
Button<br />
PowerSwitch ON/OFF<br />
Whenthe remote controlcannotbe used or<br />
forrepairingandtesting,pleaseusethis<br />
button.<br />
Force Cooling Operation<br />
Keeppressingthisbutton for5secondsto start<br />
theforcecoolingoperation.<br />
Force HeatingOperation<br />
Keeppressing thisbutton for8secondsto start<br />
theforceheating operation.<br />
Different RemoteControlling Setting<br />
Keeppressing thisbutton for11 tochange<br />
differentremote controllingsetting(A B)<br />
Mode.<br />
Signal ReceivingSound<br />
Keeppressingthisbutton for16seconds to turn<br />
off orturnonthesignal receiving sound or<br />
H14Abnormality DetectionMode.<br />
OperationIndicationLamps<br />
Power(green)<br />
Timer(orange)<br />
<strong>Air</strong> quality<br />
Green<br />
OperationMode<br />
Orange<br />
Red<br />
Lightsupinoperation;<br />
BlinksduringHotStart<br />
operation and<br />
determiningAuto<br />
Operationmode<br />
Light up in Timer Setting.<br />
Blinks in Self Diagnosis Control<br />
Cooling/Heating/Soft Dry/Auto Operation<br />
4<br />
Feature mode<br />
Powerful<br />
Quiet<br />
Anti-freezingControl for the Evaporator<br />
CoolingorSoftDry Operation<br />
TimeDelaySafetyControl<br />
The unitwillrestartoperation in3-4<br />
minutesafter each pause.<br />
WarmBooting Control<br />
Indoor fanstarts runningwhenindoor<br />
piping temperature reaches19℃ orabove.<br />
IndoorFan SpeedControl<br />
High,Med+, Med, Med-,Low<br />
Auto Fan Speed<br />
<strong>Air</strong>flowDirection Control<br />
Automatic<strong>Air</strong>flowDirection Control<br />
Thelouver automaticallyswingsup anddown<br />
Five Manual<strong>Air</strong>flowDirection Control<br />
Delayed On-timer Control<br />
For coolingorsoft dry mode,theunit<br />
starts15minutesbeforethesettime with<br />
theremotecontrol,butfor heatingmode<br />
30minutes before thesettime.<br />
Automatic Restart Control<br />
Operationis restartedafter powerfailure<br />
at previous settingmode.