09.01.2013 Views

Metrode Consumables Catalog

Metrode Consumables Catalog

Metrode Consumables Catalog

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SUPERCORE 309Mo<br />

Downhand rutile flux cored wire for dissimilar welding<br />

Product description Flux cored wire made using an austenitic stainless steel sheath and rutile flux system. The wire combines easy<br />

operability, high deposit quality and exceptional weld bead appearance for downhand and HV welding.<br />

Metal recovery is about 90% with respect to wire.<br />

Specifications AWS A5.22 E309LMoT0-4<br />

BS EN ISO 17633-A T 23 12 2 L R M 3<br />

BS EN ISO 17633-B TS309LMo-FM0<br />

ASME IX Qualification QW432 F-No 6, QW442 A-No 8<br />

Composition C Mn Si S P Cr Ni Mo Cu FN<br />

(weld metal wt %) min -- 0.5 -- -- -- 22.0 12.0 2.0 -- 15<br />

max 0.04 2.0 1.0 0.025 0.030 25.0 14.0 3.0 0.3 25<br />

typ 0.03 1.3 0.7 0.01 0.02 23 12.8 2.3 0.1 20<br />

All-weld mechanical As welded min typical<br />

properties Tensile strength MPa 550 700<br />

0.2% Proof stress MPa 350 550<br />

Elongation on 4d % 25 32<br />

Elongation on 5d % 25 30<br />

Reduction of area % -- 40<br />

Impact energy +20°C J -- 50<br />

Hardness HV -- 245<br />

Operating parameters Shielding gas: 80%Ar-20%CO2 at 20-25l/min. Proprietary gases may be used but argon should not exceed 85%.<br />

The wire is suitable for use on 100%CO2.<br />

Current: DC+ve parameters as below (for 100%CO2 increase voltage by ~3V):<br />

ø mm amp-volt range typical stickout<br />

1.2 120A-22V to 280A-34V 180A-26V 15-20mm<br />

Packaging data Spools vacuum-sealed in barrier foil with cardboard carton: 12.5kg<br />

The as-packed shelf life is virtually indefinite.<br />

Resistance to moisture absorption is high, but to maintain the high integrity of the wire surface and prevent any<br />

possibility of porosity, it is advised that part-used spools are returned to polythene wrappers.<br />

Where possible, preferred storage conditions are 60% RH max, 18°C min.<br />

Fume data Fume composition (wt %)<br />

Fe Mn Ni Cr 3<br />

Rev 05 03/07 DS: B-51 (pg 5 of 5)<br />

Cr 6<br />

Cu F OES (mg/m 3 )<br />

16 11 3 4 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!