Storage<br />

Fume data<br />

General Data for all Zeron ® 100 MMA Electrodes<br />

3 hermetically sealed ring-pull metal tins per carton, with unlimited shelf life. Direct use from tin is satisfactory<br />

for longer than a working shift of 8h. Excessive exposure of electrodes to humid conditions will cause some<br />

moisture pick-up and increase the risk of porosity.<br />

For electrodes that have been exposed:<br />

Redry 200 – 300°C/1-2h to restore to as-packed condition. Maximum 400° C, 3 cycles, 10h total.<br />

Storage of redried electrodes at 50 – 200°C in holding oven or heated quiver: no limit, but maximum 6 weeks<br />

recommended. Recommended ambient storage conditions for opened tins (using plastic lid): < 60% RH, > 18°C.<br />

Fume composition, wt % typical:<br />

Fe Mn Ni Cr Cu Mo V F OES (mg/m 3 )<br />

7 6 1 7 0.5 0.2 55<br />

- 50°C J -- > 40<br />

Hardness HV -- 270-320<br />

Operating parameters DC +ve<br />

ø mm 2.5 3.2 4.0 5.0<br />

min A 50 70 100 130<br />

max A 75 95 155 210<br />

Packaging data ø mm 2.5 3.2 4.0 5.0<br />

length mm 300 350 350 350<br />

kg/carton 12.0 14.1 13.5 13.5<br />

pieces/carton 696 360 270 172<br />

Rev 07 03/07 DS: B-61 (pg 2 of 5)