SECTION II. MAINTENANCE ALLOCATION CHART<br />

FOR<br />

GENERATOR, SIGNAL SG-747/U<br />

(HP 3300A)<br />

TM <strong>11</strong>-<strong>6625</strong>-<strong>2495</strong>-14&P<br />

(1) (2) (3) (4) (5) (6)<br />

MAINTENANCE CATEGORY<br />

TOOLS<br />

GROUP COMPONENT/ASSEMBLY MAINTENANCE AND<br />

NUMBER FUNCTION C O F H D EQUIP. REMARKS<br />

00 Generator, Signal SG-747/U Inspect .5 16 A<br />

Test 2.0 1-4, 6, 7, B<br />

<strong>11</strong><br />

Test 3.0 1-14<br />

Adjust 2.0 1-5, 10,<br />

12<br />

Calibrate * *<br />

Repair 3.0 15, 16<br />

Overhaul 4.0 1-16<br />

01 Oven Assembly A<strong>11</strong> Test 1.0 1-5,<br />

12-14<br />

Repair 1.0 15, 16<br />

Replace .5 15, 16<br />

02 Power Supply Assembly A12 Test 1.0 1-5, 12,<br />

14<br />

Repair 1.0 15, 16<br />

Replace .5 15, 16<br />

03 Antegrator Assembly A13 Test 1.0 1-5,<br />

12-14<br />

Repair 1.0 15, 16<br />

Replace .5 15, 16<br />

04 Synthesizer and Voltage A14 Test 1.0 1-5,<br />

Comparator Assembly 12-14<br />

Repair 1.0 15, 16<br />

Replace .5 15, 16<br />

05 Output Amp Assembly A15 Test 1.0 1-5,<br />

12-14<br />

Repair 1.0 15, 16<br />

Replace .5 15, 16<br />

06 Output Amp Assembly A16 Test 1.0 1-5,<br />

12-14<br />

Repair 1.0 15, 16<br />

Replace .5 15, 16<br />

07 Cable Assemblies Repair 2.0 15, 16<br />

*As per test equipment and procedure listed<br />

in the appropriate TB.<br />

D-3