Complete Door Hardware Solutions - JLM Wholesale
Complete Door Hardware Solutions - JLM Wholesale
Complete Door Hardware Solutions - JLM Wholesale
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Standard Features:<br />
Stainless Steel Construction<br />
Non Fail Safe - Unlocks when energized.<br />
Solenoid Actuated - May be energized continuously.<br />
(AC - voltage units are adjustable, to operate either quietly,<br />
on continuous duty or audibly, on intermittent duty).<br />
Keeper Depth - ½" standard.<br />
Reversible - Non Handed.<br />
Horizontal Adjustment - To compensate for misalignment.<br />
Optional Features:<br />
Latchbolt Keeper - For Pullman keeper, specify “PK”.<br />
Indication Switches - Internal switch(es) to monitor the<br />
positions of the latchbolt and/or locking cam.<br />
Specify switch options by letters:<br />
LBM - A switch to monitor the latchbolt. It indicates<br />
whether or not the latchbolt is extended into the strike.<br />
LCM - A switch to monitor the locking cam. It indicates<br />
that the strike is either locked or unlocked.<br />
LCBM - A switch to monitor both the latchbolt and the<br />
locking cam. It indicates that the latchbolt is<br />
extended into the strike, and that the strike is locked.<br />
LCBMA - This is the same as LCBM, with an additional<br />
switch activated by the latchbolt, for auxiliary purposes.<br />
AC Voltages - 12, 24 or 120 VAC, which may produce<br />
a slight “buzzing” sound.<br />
AC-SO Voltage - 12, 24, 48, or 120 VAC-SO, which are<br />
for silent operation, without the “buzzing” sound. They<br />
use a DC solenoid with an externally attached, full-wave<br />
bridge rectifier.<br />
DC Voltages - 6, 12, 24, 48 or 120 VDC.<br />
Fail Safe Operation - Locks when energized, unlocks<br />
when de-energized for applications requiring automatic<br />
unlocking in case of power failure. Specify “FS”.<br />
Model<br />
310-1 1/2<br />
310-1 3/4<br />
310-1 PK<br />
310-1 U<br />
Description<br />
Strike w/ 1/2” Keeper<br />
Strike w/ 3/4” Keeper<br />
Strike w/ PK Keeper<br />
Strike w/ U Keeper<br />
310-1 SERIES ELECTRIC STRIKES<br />
FA 5<br />
ELECTRIC STRIKES<br />
Accessories Available:<br />
Plug Connector - Specify “PC”<br />
Listings:<br />
BHMA Standard 501, Grade 1 Electric Strike<br />
310-1 Series<br />
Mid West 1-800-522-2940 South East 1-800-768-6050<br />
FAX 1-800-782-1160 FAX 1-800-824-6051<br />
<strong>JLM</strong> <strong>Wholesale</strong> 3095 Mullins Court Oxford, MI 48371 <strong>JLM</strong> <strong>Wholesale</strong> SE 7517-A Orr Rd. Charlotte, NC 28213<br />
.50<br />
.75 .625<br />
Standard 1/2" Standard 3/4" Pullman (PK)<br />
7<br />
HOW TO ORDER<br />
310-1 1/2 24VAC-SO-FS LCBM<br />
Voltage Amps Operation<br />
12VAC 1.33/.45 FSE Fail Secure<br />
24VAC .69/.24 FS Fail Safe<br />
120VAC .16/.06<br />
6VDC .97<br />
12VDC .51 SO Silent Operation<br />
24VDC .25 NOTE: AC WITH SILENT<br />
48VDC .13 OPERATION USES A<br />
120VDC .06 DC COIL & RECTIFIER<br />
310-1 APPLICATION CHART<br />
Electric 310-1 Optional<br />
Strike with Std. Keeper Keeper<br />
310-2 310-1 ½ PK<br />
310-2 W 310-1 ½ PK<br />
310-2 OB 310-1 ½ PK<br />
310-2RF 310-1 ½ PK<br />
310-2 ¾ 310-1 ¾<br />
310-2 ¾ OB 310-1 ¾<br />
310-2 ¾ U 310-1 U<br />
310-3-1 310-1 1<br />
310-4 310-1 PK ½<br />
310-4-100 310-1 PK ½<br />
310-4-1 310-1-1 PK ½<br />
310-4-2 310-1-2 PK ½<br />
310-4-3 310-1 PK (2) ½<br />
310-4-30 310-1-30 PK ½<br />
310-5 310-1 ½ PK<br />
310-6-1 310-1-1 ½ PK<br />
310-6-2 310-1-2 ½ PK<br />
310-6-3 310-1 ½ (2) PK<br />
310-6-30 310-1-30 ½ PK<br />
310-6-8 310-1 ½ PK<br />
LBM<br />
LCM<br />
LCBM<br />
LCBMA<br />
Switch Options<br />
Latchbolt Monitor<br />
Locking Cam Monitor<br />
Locking Cam & Bolt Monitor<br />
LCBM & Aux. LBM Monitor<br />
Rev. 04/04