<strong>RISH</strong> <strong>Ducer</strong> <strong>M01</strong> <strong>with</strong> <strong>RS</strong> <strong>485</strong> <strong>interface</strong><br />

Programmable multi-transducer<br />

Electrical Connections<br />

Measuring input<br />

System / application Terminals<br />

Single-phase<br />

AC system<br />

3-wire<br />

3-phase<br />

symmetric<br />

load<br />

I: L1<br />

3-wire<br />

3-phase<br />

symmetric<br />

load<br />

Phase shift<br />

U: L1 – L2<br />

I: L1<br />

3-wire<br />

3-phase<br />

symmetric<br />

load<br />

Phase shift<br />

U: L3 – L1<br />

I: L1<br />

Rishabh Instruments<br />

L1<br />

N<br />

L1<br />

L2<br />

L3<br />

2<br />

11 1 3<br />

2 5 8 1 3<br />

L1<br />

N<br />

L1<br />

L2<br />

L3<br />

2 11 1 3<br />

k l<br />

K L<br />

2 5 8 1 3<br />

k l<br />

K L<br />

L1<br />

<strong>RISH</strong>ABH INSTRUMENTS PVT.LTD.<br />

F-31, MIDC, Satpur, Nashik-422 007,India.<br />

Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064<br />

E-mail : India :- marketing@rishabh.co.in<br />

International :- exp.marketing@rishabh.co.in<br />

Web-site : www.rishabh.co.in<br />

N<br />

U<br />

L1<br />

L2<br />

L3<br />

u<br />

v<br />

V<br />

u<br />

U<br />

2 11 1 3<br />

u<br />

U<br />

v<br />

v<br />

V<br />

V<br />

k l<br />

K L<br />

2 5 8 1 3<br />

Connect the voltage according to the following table for current measurement in L2 or L3:<br />

Current transf. Terminals 2 5 8<br />

L1<br />

L2<br />

L3<br />

L2 1 3 L2 L3 L1<br />

L3 1 3 L3 L1 L2<br />

2<br />

5 1 3<br />

L1<br />

L2<br />

L3<br />

2 5 1 3<br />

k l<br />

K L<br />

L1<br />

u<br />

U<br />

v<br />

V<br />

k<br />

K L<br />

2 5 1 3<br />

Connect the voltage according to the following table for current measurement in L2 or L3:<br />

Current transf. Terminals 2 5<br />

L2 1 3 L2 L3<br />

L3 1 3 L3 L1<br />

L1<br />

L2<br />

L3<br />

8<br />

2 1 3<br />

L1<br />

L2<br />

L3<br />

8 2 1 3<br />

k l<br />

K L<br />

L2<br />

L3<br />

L1<br />

u<br />

U<br />

v<br />

V<br />

k l<br />

K L<br />

8 2 1 3<br />

Connect the voltage according to the following table for current measurement in L2 or L3:<br />

Current transf. Terminals 8 2<br />

L2 1 3 L1 L2<br />

L3 1 3 L2 L3<br />

Page 8 of 12<br />