Setting instruction Manual<br />
for boilers with<br />
<strong>SM</strong> <strong>30001</strong><br />
Printed Circuit board<br />
mod.<br />
RBC 24 (open chamber)<br />
RBS 24 (room sealed)<br />
CE 0694 TA99E009.A0704<br />
<strong>Technical</strong> Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH
INDEX<br />
CONTROL PANEL page 1<br />
<strong>SM</strong> <strong>30001</strong> ELECTRONIC PRINTED CIRCUIT BOARD:<br />
FUNCTIONS SETTING PROCEDURE page 2<br />
BOILER TYPE SETTING PROCEDURE page 2<br />
MAXIMUM GAS PRESSURE SETTING page 4<br />
MINIMUM GAS PRESSURE SETTING page 4<br />
HEATING OUTPUT SETTING page 4<br />
CENTRAL HEATING / D.H.W. MODE OPERATION page 4<br />
RESET PROCEDURE page 4<br />
TECHNICAL SPECIFICATIONS page 5<br />
GAS DATA TABLE page 6<br />
GAS PRESSURE SETTING page 6<br />
HEATING OUTPUT PRESSURE DIAGRAM page 6<br />
ELECTRICAL WIRING DIAGRAM page 7<br />
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings
1<br />
ON / OFF POWER BUTTON<br />
2<br />
HEATING TEMPERATURE ADJUSTMENT KNOB<br />
3<br />
DOMESTIC HOT WATER TEMPERATURE ADJUSTMENT<br />
KNOB<br />
4<br />
STABLE LIGHT: POWER ON<br />
FLASHING LIGHT: FLAME ON<br />
5<br />
STABLE LIGHT: 40°C TEMPERATURE<br />
FLASHING LIGHT: WATER DEFICIENCY<br />
LIGHT OFF: WATER PRESSURE LEVEL 1 bar<br />
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings<br />
CONTROL PANEL<br />
1<br />
6<br />
STABLE LIGHT: 50°C TEMPERATURE<br />
FLASHING LIGHT: FLUE SAFETY THERMOSTAT LOCK-<br />
OUT (for open chamber model only)<br />
7<br />
STABLE LIGHT: 60°C TEMPERATURE<br />
FLASHING LIGHT: FLAME LOCK-OUT<br />
8<br />
STABLE LIGHT: 70°C TEMPERATURE<br />
FLASHING LIGHT: HIGH LIMIT THERMOSTAT LOCK-OUT<br />
9<br />
STABLE LIGHT: 80°C TEMPERATURE<br />
FLASHING LIGHT: D. HOT WATER / HEATING SENSOR<br />
FAILURE
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings<br />
M12<br />
M11<br />
M1<br />
M2<br />
<strong>SM</strong> <strong>30001</strong> PRINTED CIRCUIT BOARD<br />
cod. 76666LA<br />
M13 M3<br />
M8<br />
M6<br />
M4<br />
M9<br />
FUNCTIONS SETTING<br />
1-A STANDARD 30-80°C - OFF<br />
REDUCED 25-40°C - ON<br />
2-B ACTIVE - OFF<br />
DISCONNECTED - ON<br />
3-C DISCONNECTED - OFF<br />
ACTIVE - ON<br />
4-D 64-65°C - OFF<br />
58-61°C - ON<br />
BOILER TYPE SETTING<br />
5-E OFF<br />
ON<br />
6-F OFF<br />
ON<br />
6-F OFF<br />
2<br />
ON<br />
�<br />
�<br />
�<br />
�<br />
M5<br />
M7<br />
M10<br />
HEATING TEMPERATURE<br />
SETTING<br />
SHORT-CYCLING Function<br />
TIMER (3 min.)<br />
WATER-HAMMER Prevention<br />
� Function<br />
HOT WATER<br />
TEMPERATURE<br />
SETTING<br />
NOT APPLICABLE<br />
DUAL CIRCUIT EXCHANGER type<br />
� INSTANTANEOUS TYPE BOILER<br />
�<br />
NOT APPLICABLE<br />
NATURAL GAS OPERATION<br />
L.P.G. OPERATION
CONTROL<br />
PANEL<br />
CONTROLS (fig. 1-2)<br />
8 9 10 11 12 13<br />
1 2 3 4<br />
1. “MAXR” MAXIMUM HEATING POTENTIOMETER<br />
2. “MIN” MINIMUM GAS POTENTIOMETER<br />
3. “RLA” STARTING STEP POTENTIOMETER<br />
4. “SPAZ” CHIMNEY-SWEEPER FUNCTION<br />
5. GAS PRESSURE POINT - OUTLET<br />
6. GAS ADJUSTMENT SCREW<br />
7. GAS PRESSURE POINT – INLET<br />
8. STABLE LIGHT: POWER ON<br />
FLASHING LIGHT: FLAME ON<br />
9. STABLE LIGHT: 40°C TEMPERATURE<br />
FLASHING LIGHT: WATER DEFICIENCY<br />
LIGHT OFF: WATER PRESSURE LEVEL 1.2 bar<br />
10. STABLE LIGHT: 50°C TEMPERATURE<br />
Fig. 2<br />
GAS VALVE<br />
NORDGAS<br />
NV0111122901<br />
FLASHING LIGHT: FLUE SAFETY THERMOSTAL LOCK-OUT (for open chamber model only)<br />
11. STABLE LIGHT: 60°C TEMPERATURE<br />
FLASHING LIGHT: FLAME LOCK-OUT<br />
12. STABLE LIGHT: 70°C TEMPERATURE<br />
FLASHING LIGHT: HIGH LIMIT THERMOSTAT LOCK-OUT<br />
13. STABLE LIGHT: 80°C TEMPERATURE<br />
FLASHING LIGHT: D. HOT WATER / HEATING SENSOR FAILURE<br />
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings 3<br />
5<br />
6<br />
7<br />
Fig. 1
MAXIMUM GAS PRESSURE SETTING<br />
• Unscrew 5 gas pressure point screw (fig. 1) on the gas valve and insert a manometer;<br />
• Turn heating and domestic hot water setting knobs to the maximum and remove the 2 knob by<br />
extracting them with a pliers:<br />
• Use a Ø2.5 ÷ 3 mm cross-type screwdriver and turn “maxR” 1 potentiometer (fig. 2) clockwise to the<br />
maximum;<br />
• Switch the boiler ON;<br />
• Keep 4 potentiometer (chimney sweeper function) (fig. 2) pressed for 10 seconds;<br />
• The manometer will show the maximum gas pressure value; if that value is different than the one<br />
stated on the Data Plate (see Gas pressure adjustment table pag. 6), modify it as follows: turn the 6<br />
gas adjustment screw (fig. 1) clockwise to increase gas pressure and counter clockwise to decrease<br />
gas pressure to reach the data Plate pressure value.<br />
MINIMUM GAS PRESSURE SETTING<br />
• Turn “maxR” 1 potentiometer (fig. 2) counter clockwise to the minimum;<br />
• Turn 2 potentiometer (minimum gas) (fig. 2) clockwise to increase or counter clockwise to decrease<br />
the gas pressure;<br />
• Turn 3 potentiometer (starting step) (fig. 2) to the middle position of its full setting;<br />
HEATING OUTPUT SETTING<br />
• Turn the “maxR” 1 potentiometer (maximum heating) (fig. 2) clockwise and set the pressure value<br />
according to the system requirement. (see Heating Output Pressure Diagram at page 6);<br />
• Remove the silicon pipe from the pressure point 5 (fig. 1);<br />
• Close tightly the pressure point screw and make sure there are no gas leaks;<br />
• Fit the 2 plastic knobs back to position;<br />
• Put ON/OFF button in OFF and than ON position.<br />
CENTRAL HEATING / DOMESTIC HOT WATER MODE OPERATION<br />
If the boiler has to operate on both central heating and domestic hot water mode, do NOT set the central<br />
heating and d.h. water knobs to the minimum (zero);<br />
• Set the domestic hot water knob to ‘0’ (zero) for a HEATING ONLY mode;<br />
• Set the central heating knob to ‘0’ (zero) for a WATER ONLY mode;<br />
RESET PROCEDURE<br />
In case of a ‘Flame Lock-out’ (indicator 11 or 12 fig. 2 page 3), reset the boiler by putting the ON/OFF<br />
button in OFF and than ON position.<br />
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings 4
TECHNICAL SPECIFICATION<br />
New generation printed circuit board with easy settings of boiler parameters.<br />
Special features:<br />
Main functions / features<br />
� Chimney-sweeper function (15 minutes)<br />
� Pump over-run function (2 minutes)<br />
� Pump inactivity protection system<br />
� Water-Hammer prevention function<br />
� Suitable for outside temperature sensor connection<br />
� Suitable for remote control system connection<br />
� Self-diagnostic<br />
� Continuous electronic modulation for central heating and domestic hot water<br />
� Adjustable heating output<br />
� Adjustable starting step<br />
Exclusively for technicians settings<br />
� Standard / reduced heating temperature from 30 to 80 °C / 25 to 40°C<br />
• Water-Hammer prevention function<br />
• Short cycling function-3 minutes stand-by, heating circuit<br />
• Maximum gas pressure setting<br />
• Minimum gas pressure setting<br />
• Heating output setting<br />
User Settings<br />
• On / Off operation<br />
• Heating temperature adjustment from 30 to 80 °C / 25 to 45°C<br />
• Domestic Hot Water adjustment from 35 to 65 °C<br />
• Mode selection knob: summer/winter/heating only<br />
• Lock-out<br />
• Normal water pressure<br />
• Water deficiency safety switch<br />
• Temperature indicator<br />
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings 5
model: RBC 24 RBS 24<br />
GAS DATA TABLE<br />
NATURAL GAS<br />
G 20<br />
LIQUID BUTAN GAS<br />
G 30<br />
LIQUID PROPANE<br />
GAS G 31<br />
Lower Wobbe index (15°C; 1013<br />
mbar)<br />
MJ/Nm 3 45.67 80.58 70.69<br />
Rated feed pressure mbar 20 30 37<br />
Minimum feed pressure mbar 17 20 25<br />
Main burner: 12 Jets - Ø jet mm 1.30 0.77 0.77<br />
Consuption (15°C; 1013 mbar) m 3 /h 2.71 - -<br />
Consuption (15°C; 1013 mbar) kg/h - 2.019 1.99<br />
GAS PRESSURE SETTING<br />
models Natural Gas G 20 G.P.L. G 30/31<br />
min. max. min. max<br />
RBC 24 mbar 2.2 10.8 5 30<br />
RBS 24 mbar 1.5 10.4 5 30<br />
Heating Output in kW<br />
28<br />
26<br />
24<br />
22<br />
20<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
NATURAL GAS<br />
HEATING OUTPUT MAXIMUM PRESSURE DIAGRAM<br />
(G20 Natural Gas - G30/31 L.P.G.)<br />
L.P.G.<br />
0<br />
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33<br />
Gas pressure in mbar<br />
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings 6<br />
mod.<br />
RBC 24<br />
(open<br />
chamber)<br />
RBS 24<br />
(room<br />
sealed)
lack<br />
PRINTED CIRCUIT BOARD <strong>SM</strong><strong>30001</strong> (COD. 76666LA)<br />
brown<br />
M12<br />
M11<br />
M1<br />
M2<br />
PAC<br />
1,5bar<br />
18<br />
SS<br />
red/black<br />
light-blue<br />
light-blue<br />
19<br />
black<br />
M13<br />
light-blue<br />
white/black<br />
EA TR<br />
5<br />
brown<br />
+ -<br />
M10<br />
black<br />
brown<br />
M8<br />
SR MF<br />
black<br />
45 46 47 48 49 50<br />
C<br />
6 7 8 9<br />
brown<br />
grey<br />
M5<br />
TS<br />
VG<br />
OP<br />
M3<br />
black<br />
M6<br />
light-blue<br />
M4<br />
1 4<br />
VG<br />
3<br />
green<br />
white<br />
45 46 47 48 49 50<br />
M12<br />
L<br />
N<br />
WIRING DIAGRAM<br />
red<br />
PA<br />
51<br />
blue<br />
52<br />
52 T P<br />
1 2 3 4<br />
P.C.B. <strong>SM</strong> <strong>30001</strong> – boiler settings 7<br />
light-blue<br />
orange<br />
brown<br />
IG<br />
orange<br />
2<br />
230V<br />
50 Hz<br />
L N<br />
light-blue<br />
M5<br />
M7<br />
M9 M10<br />
M9<br />
M8<br />
M2<br />
black<br />
230V<br />
50 Hz<br />
TF<br />
52 T<br />
brown<br />
P<br />
TA SE<br />
black<br />
18<br />
orange<br />
M3<br />
orange<br />
51 52 53 54<br />
18<br />
ER<br />
KEY<br />
L<br />
N<br />
PAC<br />
IG<br />
SS<br />
SR<br />
C<br />
TS<br />
M.F.<br />
TA<br />
TF<br />
PA<br />
EV<br />
VG<br />
EA<br />
ER<br />
TR<br />
Optional<br />
TERMINAL<br />
BLOCK<br />
M7<br />
M13<br />
M8<br />
- LINE<br />
- NEUTRAL<br />
- WATER PRESSURE SWITCH<br />
- MAIN SWITCH<br />
- D.H. WATER SENSOR<br />
- HEATING SENSOR<br />
- CIRCULATION PUMP<br />
- SAFETY THERMOSTAT<br />
- ELECTRONIC FLOWSWITCH<br />
- ROOM THERMOSTAT<br />
- SAFETY FLUE THERMOSTAT<br />
- AIR PRESSURE SWITCH<br />
- FAN<br />
- GAS VALVE<br />
- IGNITION ELECTRODE<br />
- IONISATION ELECTRODE<br />
- TRANSFORMER<br />
brown<br />
L<br />
18<br />
EV<br />
light-blue<br />
N<br />
19<br />
M11
RADIANT BRUCIATORI s.p.a.<br />
Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU)<br />
Tel. +39 0721 9079.1 • fax. +39 0721 9079279<br />
e-mail: tecnico@radiant • Internet: http://www.radiant.it<br />
ALL DESCRIPTIONS AND ILLUSTRATIONS CONTAINED IN THIS LEAFLET HAVE<br />
BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES<br />
AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE<br />
ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET. E + OE<br />
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED,<br />
SAVED IN STORAGE SYSTEMS OR TRAN<strong>SM</strong>ITTED IN ANY FORM OR BY ANY<br />
MEANS, WHETHER ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING<br />
OR OTHERS, WITHOUT THE MANUFACTURER'S PRIOR AUTHORISATION IN<br />
WRITING.<br />
TA99E009.A0704