Operating Manual for BAUER CENTERSTAR 5000<br />

5. Turn the "SAFETY CIRCUIT" switch “ON".<br />

6. Check correct start-up of CENTERSTAR by a test start (starting button "FORWARD START" and<br />

"REVERSE START".<br />

10.2 RESTART AFTER DOGLEGGING – WITHOUT TOWER ALIGNMENT SWITCH<br />

1. Set SPEED" at 100 %.<br />

WARNING!<br />

2. Turn the “SAFETY CIRCUIT" switch to "OFF".<br />

In “OFF” position, the "SAFETY CIRCUIT" switch deactivates the safety system.<br />

3. Set proper running direction. Select that direction that brings the outermost<br />

system end into radial alignment.<br />

This means, if the outer, doglegged tower column is pointing “FORWARD”, you<br />

have to push the REVERSE START button; if the outer doglegged tower<br />

column is pointing in “REVERSE” direction, push “FORWARD”.<br />

Press the green "FORWARD START" or "REVERSE START" button and check<br />

the running direction when the outer, misaligned towers start moving.<br />