25.01.2013 Views

CHAPTER 2 THEORY OF OPERATION - Snap-on Equipment

CHAPTER 2 THEORY OF OPERATION - Snap-on Equipment

CHAPTER 2 THEORY OF OPERATION - Snap-on Equipment

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<str<strong>on</strong>g>CHAPTER</str<strong>on</strong>g> 2 <str<strong>on</strong>g>THEORY</str<strong>on</strong>g> <str<strong>on</strong>g>OF</str<strong>on</strong>g> <str<strong>on</strong>g>OPERATION</str<strong>on</strong>g><br />

COMPLAINT CORRECTIVE ACTION<br />

IV. No Vacuum or vacuum is weak,<br />

or less then 25 inches.<br />

(Model EEAC316 <strong>on</strong>ly)<br />

V. No vacuum or vacuum is weak,<br />

or less then 25 inches.<br />

(Model EEAC318 <strong>on</strong>ly)<br />

Check for debris in the Oil return solenoid?<br />

NO–> Refer to Chapter 1 AC/DC.<br />

Disc<strong>on</strong>nect the sucti<strong>on</strong> side of the compressor. C<strong>on</strong>nect a gauge set<br />

yellow hose to the compressor. Open inline hand valve <strong>on</strong> yellow<br />

hose, and open low side valve <strong>on</strong> gauge set. Set the unit up for a<br />

Vacuum operati<strong>on</strong>. Does the gauge set read 25” to 29”?<br />

NO–> Disc<strong>on</strong>nect oil return tube from compressor and block<br />

off compressor side. Does the gauge set read 25” to<br />

29”?<br />

NO–> Replace Compressor.<br />

YES–> Clean or replace Oil Solenoid.<br />

Disc<strong>on</strong>nect yellow hose from compressor and rec<strong>on</strong>nect compressor<br />

to the input side of the master filter/dryer.<br />

Does Vacuum Pump Start?<br />

NO–> Refer to Chapter 1 AC/DC.<br />

YES–> Disc<strong>on</strong>nect the sucti<strong>on</strong> side of the Vacuum Pump. C<strong>on</strong>nect a<br />

gauge set yellow hose to the compressor. Open inline hand<br />

valve <strong>on</strong> yellow hose, and open low side valve <strong>on</strong> gauge set.<br />

Set up a vacuum operati<strong>on</strong>. Does the gauge set read 25” to<br />

29”?<br />

YES–> Check for leaking solenoids (S4 or S3), leaking hand<br />

valves or leaking hoses / fittings.<br />

NO–> Check oil level in Vacuum Pump – replace Vacuum<br />

Pump.<br />

TROUBLESHOOTING COMPLETE<br />