Structure selection and design Copyright Prof Schierle 2012 1
Structure selection and design Copyright Prof Schierle 2012 1
Structure selection and design Copyright Prof Schierle 2012 1
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Residential <strong>and</strong> schools<br />
Manufacturing<br />
ASCE 7, page 10<br />
ASCE 7 Table 4.1 excerpts of common live loads<br />
Assembly<br />
fixed seating = 60 psf<br />
movable seating = 100 psf<br />
light = 125 psf<br />
heavy = 250 psf<br />
reading room = 60 psf<br />
stack room = 150 psf<br />
<strong>Structure</strong> <strong>selection</strong> <strong>and</strong> <strong>design</strong> <strong>Copyright</strong> <strong>Prof</strong> <strong>Schierle</strong> <strong>2012</strong> 16<br />
Office<br />
Library<br />
40 psf<br />
50 psf<br />
Live load reduction<br />
Since large members are unlikely fully loaded,<br />
ASCE 7 allows live load reductions<br />
(except for public spaces <strong>and</strong> LL ≥ 100 psf):<br />
For members supporting ≥ 600 sq. ft.<br />
Reduction shall not exceed<br />
50% for members supporting 1 floor,<br />
60 % for members supporting 2 or more floors