ContRoLs<br />

(continued)<br />

Specifications<br />

32 520L0519 • Rev FN • July 2009<br />

Series 45 Axial Piston Open Circuit Pumps<br />

Technical Information<br />

Frames L and K<br />

electric proportional control (eJ) (normally closed)<br />

PC control setting range<br />

model bar psi<br />

L25C,<br />

K38C<br />

L30D,<br />

K45D<br />

Schematic diagram EJ schematic<br />

Legend<br />

X<br />

B = Outlet<br />

S = Inlet<br />

L1, L2 = Case drain<br />

M2 = System pressure gauge port<br />

X = Remote PC port<br />

M2<br />

L2<br />

B<br />

100-260 bar 1450-3370<br />

100-210 bar 1450-3045<br />

S L1<br />

P106 687E<br />

LS setting range<br />

model bar psi<br />

all 12-40 174-580