muLti-funCtion vaLves<br />

(continued)<br />

M<br />

M1<br />

M4<br />

M5<br />

M2<br />

S<br />

Series 90 Axial Piston Pumps<br />

Technical Information<br />

Features and options<br />

18 520L0603 • Rev FC • August 2008<br />

Multifunction valve, pressure limiter, pressure regulation, option 1<br />

M3<br />

L2<br />

A<br />

B<br />

Servo <strong>piston</strong><br />

Port A<br />

Port B<br />

Servo <strong>piston</strong><br />

To control<br />

Servo pressure<br />

relief valves<br />

Multifunction valve<br />

Multifunction valve<br />

Charge<br />

pressure<br />

relief valve<br />

bypass function<br />

In some applications it is desirable to bypass fluid around the variable displacement<br />

pump when pump shaft rotation is either not possible or not desired. For example, an<br />

inoperable vehicle may be moved to a service or repair location or winched onto a trailer<br />

without operating the prime mover. To provide for this, Series 90 <strong>pumps</strong> are designed<br />

with a bypass function.<br />

The bypass is operated by mechanically rotating the bypass hex on both multifunction<br />

valves three (3) turns counterclockwise (CCW). This connects working loop A and B and<br />

allows fluid to circulate without rotating the pump and prime mover.<br />

C Caution<br />

Possible pump and/or motor damage<br />

Bypass valves are intended for moving a machine or vehicle for very short distances at<br />

very slow speeds. They are NOT intended as tow valves.<br />

A<br />

B<br />

C<br />

Bypass hex<br />

adjustment<br />