20364044.p65/081105<br />
Parameter settings for recommended <strong>Demag</strong> DIC Dedrive Compact frequency inverter<br />
Please refer to the table below for the required parameter settings.<br />
For the <strong>hoist</strong> drives, rotary encoder feedback on the motor is required. We recommend that the <strong>Demag</strong> AG 2 external pulse generator<br />
be used together with the EM-ENC-02 extension module for the <strong>Demag</strong> Dedrive Compact frequency inverter.<br />
After entry of the rated motor values, it is absolutely necessary to perform parameter identification.<br />
No. Name Unit ZBA ZBR<br />
71B4 90A4 100 B4<br />
112 A4<br />
132 B4<br />
132<br />
C4<br />
6 0%<br />
5 0%<br />
60%<br />
030 Configuration - 410 210<br />
370 Rated voltage<br />
V 220<br />
371 Rated current<br />
A 2, 6<br />
5, 1 16, 9 18, 7 29, 0 46, 5 38,<br />
0<br />
372 Rated speed<br />
rpm 1375 1400 1350 1430 1420 1410 1425<br />
373 No. of<br />
pole<br />
pairs<br />
- 2<br />
374 Rated cosine<br />
phi<br />
- 0, 54<br />
0, 74<br />
0, 85<br />
0, 84<br />
0, 87<br />
0, 83<br />
0,<br />
84<br />
375 Rated frequency<br />
Hz 50<br />
376 Mech. rated<br />
output<br />
kW 0, 4<br />
1, 1 4, 2<br />
5, 3<br />
8, 3 13, 1 10,<br />
2<br />
417 Frequency switch-off<br />
limit<br />
Hz 250 100<br />
418 Min. frequency<br />
Hz 5 8<br />
419 M ax.<br />
frequency<br />
1) Hz120 84 85 86<br />
420 Acceleration Hz/ s<br />
25 42 42, 5<br />
43<br />
421 Deceleration Hz/ s<br />
50 42 42, 5<br />
43<br />
490 Operating mode<br />
encoder<br />
1<br />
- 0 4<br />
491<br />
Pulse<br />
number<br />
per<br />
revolution<br />
of<br />
encoder<br />
1<br />
- - Depending<br />
on<br />
rotary<br />
encoder<br />
used<br />
721 Amplification speed<br />
controller<br />
- 3 10<br />
722<br />
Integral<br />
action<br />
controller<br />
time<br />
speed<br />
ms200 100<br />
For further details regarding commissioning, the many control possibilities, the various <strong>hoist</strong> functions and the selection of further<br />
additional components of the DIC Dedrive Compact, refer to the operating instructions 214 708 44 and 214 716 44. The permissible<br />
ambient conditions must be complied with.<br />
1) At 380 V, the max. frequency must be reduced by 5 Hz.<br />