20364044.p65/081105<br />

Parameter settings for recommended <strong>Demag</strong> DIC Dedrive Compact frequency inverter<br />

Please refer to the table below for the required parameter settings.<br />

For the <strong>hoist</strong> drives, rotary encoder feedback on the motor is required. We recommend that the <strong>Demag</strong> AG 2 external pulse generator<br />

be used together with the EM-ENC-02 extension module for the <strong>Demag</strong> Dedrive Compact frequency inverter.<br />

After entry of the rated motor values, it is absolutely necessary to perform parameter identification.<br />

No. Name Unit ZBA ZBR<br />

71B4 90A4 100 B4<br />

112 A4<br />

132 B4<br />

132<br />

C4<br />

6 0%<br />

5 0%<br />

60%<br />

030 Configuration - 410 210<br />

370 Rated voltage<br />

V 220<br />

371 Rated current<br />

A 2, 6<br />

5, 1 16, 9 18, 7 29, 0 46, 5 38,<br />

0<br />

372 Rated speed<br />

rpm 1375 1400 1350 1430 1420 1410 1425<br />

373 No. of<br />

pole<br />

pairs<br />

- 2<br />

374 Rated cosine<br />

phi<br />

- 0, 54<br />

0, 74<br />

0, 85<br />

0, 84<br />

0, 87<br />

0, 83<br />

0,<br />

84<br />

375 Rated frequency<br />

Hz 50<br />

376 Mech. rated<br />

output<br />

kW 0, 4<br />

1, 1 4, 2<br />

5, 3<br />

8, 3 13, 1 10,<br />

2<br />

417 Frequency switch-off<br />

limit<br />

Hz 250 100<br />

418 Min. frequency<br />

Hz 5 8<br />

419 M ax.<br />

frequency<br />

1) Hz120 84 85 86<br />

420 Acceleration Hz/ s<br />

25 42 42, 5<br />

43<br />

421 Deceleration Hz/ s<br />

50 42 42, 5<br />

43<br />

490 Operating mode<br />

encoder<br />

1<br />

- 0 4<br />

491<br />

Pulse<br />

number<br />

per<br />

revolution<br />

of<br />

encoder<br />

1<br />

- - Depending<br />

on<br />

rotary<br />

encoder<br />

used<br />

721 Amplification speed<br />

controller<br />

- 3 10<br />

722<br />

Integral<br />

action<br />

controller<br />

time<br />

speed<br />

ms200 100<br />

For further details regarding commissioning, the many control possibilities, the various <strong>hoist</strong> functions and the selection of further<br />

additional components of the DIC Dedrive Compact, refer to the operating instructions 214 708 44 and 214 716 44. The permissible<br />

ambient conditions must be complied with.<br />

1) At 380 V, the max. frequency must be reduced by 5 Hz.<br />