1. AAM 2<br />
2. Alarms 4<br />
3. BACnet 6<br />
4. Charts 6<br />
5. Conversion-Tool EY3600 7<br />
6. Data Exchange 7<br />
7. Dongle 8<br />
8. Drivers 9<br />
9. Error Messages 10<br />
10. General 13<br />
11. Images 14<br />
12. Installation 15<br />
13. Network 17<br />
14. novaPLC 18<br />
15. Product quality of novaPro Open 19<br />
16. Reports 19<br />
17. Tags 19<br />
18. User Management 20<br />
19. VPIWNS36 (Driver EY3600) 23<br />
20. Web 25<br />
21. Web Scheduler 28<br />
22. WizReportXL 29<br />
23. ZP2400 Web 29<br />
24. ZP3600 Web 31<br />
25. Starting 31<br />
26. Codesys 32<br />
27. Server 2003 32<br />
28. Documentation 32<br />
Status: Dokument freigegeben 4A Fr. Sauter <strong>AG</strong> Ersteller: willijos 23.02.2009<br />
Öffentlichkeit: 2 - Systemhaus Seite 1 von 32 Änderer:
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
1. AAM<br />
seit<br />
Version<br />
17. Nov 05 The mail server requires password<br />
authentication . Where can I set the<br />
password?<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 2 von 32<br />
In the control panel->Mail->Mail Accounts-<br />
>Edit existing accounts<br />
21. Okt 05 2.00 The email service does not work This problem is fixed with Jericho version<br />
71a.<br />
Please contact the support from SBA to<br />
22. Jul 05 2.00 In User time table - yearly schedule, the<br />
hour 00:00 can not be assigned to a team.<br />
obtain it.<br />
Workaround: 1. Assign 00:00 and 01:00 by<br />
dragging the mouse over two fields.<br />
2. Deselect hour 01:00<br />
05. Jul 05 1.00 Which modems are compatible with AAM? Please find the list at:<br />
http://www.micromedia-int.com/ -> Support<br />
28. Jun 05 2.00 AAM-configuration gets lost when installing<br />
a new release.<br />
-> Modems<br />
Save your AAM settings under the project<br />
path. In folder "...novaPro Open/Bin" file<br />
"Jericho.cfg" can be found. Empty by<br />
default. Open it and enter your project path.<br />
All files of type ini from AAM are saved in<br />
your project folder afterwards.<br />
14. Mrz 05 The AAM service Winpopup does not work. This service requires, that the Windows<br />
messenger service is started on the target<br />
machine.<br />
To start, open the properties of the<br />
messenger service in "Control panel-<br />
>Administrative tools->Services", and<br />
04. Mrz 05 AAM: SMS with Nokia 30 fails with error<br />
message "no port defined for this service"<br />
04. Mrz 05 1.12 Can I send messages prioritised according<br />
to the severity?<br />
select "Start automatically".<br />
In the AAM modems definition do not use<br />
the Tapi modem for the Nokia 30, but the<br />
direct port definition<br />
Yes, in the tab AAM from the station<br />
properties you can check this option.<br />
2005/102_FER<br />
2005/101_FER<br />
ECR2618_SCP<br />
2005/095_FER<br />
2005/092_SCP<br />
2005/089_FER<br />
2005/085_FER<br />
2005/086_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
15. Dez 04 1.12 No e-mail are sent after synchronisation of<br />
Jericho cannot coexist in different<br />
2004/078_SCP<br />
central user management with local<br />
languages on a same network when using<br />
database<br />
E-mails services in AAM and Centralized<br />
User Management.<br />
Information about Email accounts for users<br />
are stored in the User Management<br />
Database have different formats depending<br />
on the configured language of Jericho.<br />
You cannot have nPO with English Jericho<br />
on one PC and Jericho in German on<br />
another PC when using E-mails services in<br />
AAM and Centralized User Management.<br />
In case of a synchronization of the Central<br />
User Management Database (based on<br />
MSSQL2000) with a Local User<br />
Management Database (based on<br />
Access2000), entries that are in conflict will<br />
be considered faulty and deleted.<br />
Make sure that Jericho is set up with the<br />
same language on all machines before<br />
performing synchronization.<br />
09. Jun 04 1.12 After the Update from nPO 1.11 to 1.12 an<br />
The file semaphone.dll is not used anymore 2004/070_Pho<br />
error message regarding the file<br />
sine version 1.12 and therefore is not<br />
semaphone.dll appears when opening nPO<br />
installed. Delete (or put a semicolon in front<br />
with AAM.<br />
of) the entry semaphore in the file pager.ini<br />
within the bin folder of nPO (novaPro_Open<br />
Suite\novaPro Open\Bin)<br />
13. Apr 04 1.12 Send SMS through Hotmail account Set up a Hotmail account<br />
http://www.hotmail.com<br />
- New account Sign Up<br />
- E-Mail forwarding, MSN Mobile Hotmail<br />
- Select your country<br />
- Select your mobile phone provider, enter<br />
mobile phone number<br />
2004/067_SCP<br />
Fr. Sauter <strong>AG</strong><br />
Seite 3 von 32
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
2. Alarms<br />
seit<br />
Version<br />
18. Aug 06 Event summaries are inconsistent from one<br />
station to the other. It is not possible to<br />
acknowledge or force end.<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 4 von 32<br />
- Accept the contract terms of Hotmail and<br />
your Mobile Phone Provider<br />
- Hotmail sends now an SMS to your mobile<br />
phone. Enter the activation code from the<br />
SMS<br />
- Configure Junk-Mail Filter<br />
Hotmail forwards now all incoming e-mails<br />
as an SMS to your mobile phone number.<br />
This may happen, if a single network station<br />
has crashed.<br />
Please shut down all stations, delete<br />
LRM.DAT on all stations and restart them.<br />
2006/126_FER<br />
18. Aug 06 Alarms are printed twice Cause: the same printer was defined as an<br />
alarm and report printer.<br />
2006/127_FER<br />
13. Okt 03 The entries in the event summary show<br />
Is caused by data transmission errors from 2003/053_FER<br />
empty or erratic data (e.g. date 1970)<br />
some RAID controllers (seen on RAID1<br />
controller of the 6000 and 7000 series of<br />
3ware). Install application on different drive<br />
or RAID controller. The RAID controllers of<br />
the PDM's delivered by SBA behave<br />
correctly!<br />
28. Feb 03 1.00 Alarms are not printed at<br />
Copy the file "alarms.prt" into the project 2003/043_SCP<br />
acknowledgement.<br />
folder. With this file you can define, what<br />
alarm states have to be printed.<br />
A sample file including documentation can<br />
be found in archive "Alarms.zip" of SR2 of<br />
Version 1.0 on Sauter-Intra.<br />
This patch also works with novaPro_Open<br />
1.1.<br />
28. Feb 03 1.00 How can we prints alarms in different<br />
Copy the file "alarms.prt" into the project 2003/044_SCP<br />
colours depending on the alarm status?<br />
folder. With this file you can define, what
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
E.g. "Alarm started" is printed in red and<br />
"Alarm ended" is printed in black.<br />
29. Jan 03 1.10 Communication error popup shows up<br />
when loosing connection with other<br />
novaPro Open stations, although it has<br />
been deselected in the "Network<br />
communication errors" tab from the alarm<br />
properties<br />
20. Jan 03 1.00 How can the time format of an event<br />
summery be changed?<br />
16. Jan 03 1.0 Acknowledgement by phone:<br />
Can not acknowledge alarm with the key "*"<br />
16. Jan 03 1.0 Acknowledgement by phone:<br />
The key "*" acknowledges more than one<br />
alarm at once<br />
16. Jan 03 1.0 Alarms are not safely reported when they<br />
are generated simultaneously for different<br />
services<br />
(with ISDN Fritz Card)<br />
12. Apr 02 1.00 When sending alarms through E-mail, the<br />
line "subject" remains empty (German<br />
version only). The main text of the mail<br />
contains no carriage returns.<br />
Fr. Sauter <strong>AG</strong><br />
Seite 5 von 32<br />
alarm states have to be printed and in what<br />
colour using ESC sequences of your line<br />
printer.<br />
A sample file including documentation can<br />
be found in archive "Alarms.zip" of SR2 of<br />
Version 1.0 on Sauter-Intra.<br />
This patch also works with novaPro_Open<br />
1.1.<br />
Refer also to project nPO_Template.<br />
1.1 The pop up also needs to be deselected in<br />
the Protocol tab from the network<br />
configuration.<br />
Open the context menu of Alarms in<br />
novaPro Open studio - Properties - Tap<br />
"Time Format".<br />
2003/039_FER<br />
2003/024_SCP<br />
On some digital phone switches it is<br />
necessary to enable tone dialling (e.g.<br />
System 11 on Siemens or DTMF on<br />
Alcatel)<br />
2003/027_FER<br />
1.11 Will be fixed with Version 1.11 2003/028_FER<br />
1.11 All services should use the same ISDN<br />
channel (Jericho can not use<br />
simultaneously both channels). The dial up<br />
connection may use the second channel.<br />
Delete the file email_ext.dll from the<br />
program folder of novaPro Open. From now<br />
on the configuration of the mail service is in<br />
English only. However the mail that's sent<br />
2003/029_FER<br />
2002/013_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
07. Feb 02 1.00 Acknowledgment of an alarm<br />
The state alarm acknowledged is not sent<br />
to the EY3600 automation station.<br />
3. BACnet<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
11. Jul 06 2.1SP1 Initialization of the BACnet driver vpiwnbcn File: VPIBCNxx.int<br />
4. Charts<br />
18. Aug 06 Trend lines are interrupted or not drawn to<br />
the edges.<br />
Fr. Sauter <strong>AG</strong><br />
Seite 6 von 32<br />
on alarm comes in German with correct<br />
"subject"-line and well structured main text.<br />
novaPro Open acknowledges alarms on<br />
management level (novaPro Open) only.<br />
COMERRRETRYCOUNT 5<br />
BROADCASTTIMEOUT 120<br />
DEVICEMONITORPERIOD 60<br />
HISTORYBUFFERSIZE 11<br />
WHOISTIMEOUT 8<br />
Initialization of driver version 2.2.0.0 and<br />
BACnet-Browser 2.2.1.0.<br />
This drivers supports up to 4096 objects<br />
per device and up to 1024 devices.<br />
2.1 SP1 Patch 38 Please disable the hardware acceleration of<br />
the (control panel ->Display->Settings-<br />
>Advanced->Troubleshooting->turn slider<br />
of Hardware acceleration to the very left)<br />
2002/005_SCP<br />
2006/120_SCP<br />
2006/132_FER<br />
22. Okt 04 1.12 SP1 Charts are printed mirror-inverted. 1.12 SP2<br />
If this doesn't help:<br />
please install novaPro Open 2.1 SP1 Patch<br />
38.<br />
Fixed with novaPro Open 1.12 SP2 2004/073_FER<br />
05. Mai 04 1.12 The chart graph description is overlapping<br />
Set Wiztune Parameter<br />
ECR1764_SCP<br />
with scale if 3 or more digits are used in<br />
CHART_SCALE_EXTRA_WIDTH
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
01. Nov 02 1.00<br />
scale.<br />
Multiple lines in Routel Installation Charts If the historical data of the AS are treated<br />
(with the HI Tag), lines can show up twice<br />
since the values are stored by novaPro<br />
Open at the same time. In this case the line<br />
"VFI5FST_MODE_TIMESTAMP=YES" has<br />
to be added to the WizTune.dat file.<br />
2002/021_Pho<br />
5. Conversion-Tool EY3600<br />
09. Sep 05 When trying to import the alarms an error<br />
message appears: Line xx : ‘Number of<br />
Items’. Want to correct?<br />
16. Jan 03 1.0 Error messages when importing tags<br />
generated with the conversion tool.<br />
16. Jan 03 1.0 Error messages when importing alarms<br />
generated with the conversion tool.<br />
16. Aug 02 1.00 When importing EY3600 tags an error<br />
message is displayed, that the import list<br />
contains duplicate tag definitions.<br />
18. Mrz 02 1.00 The conversion tool EY3600<br />
(CONV_EY3600.EXE) novaPro Open<br />
causes errors with alarms when you import<br />
the csv-file into novaPro Open. These<br />
alarms can not be edited any more.<br />
(On our WEB-Project the system load of<br />
novaPro Open was 100% when the alarm<br />
occurred.<br />
6. Data Exchange<br />
Fr. Sauter <strong>AG</strong><br />
Seite 7 von 32<br />
Make sure that the alarm family does not<br />
end with a space.<br />
Always use the conversion tool for your<br />
program version.<br />
Import tags first, than the alarms. Otherwise<br />
the alarms will reference non existing tags.<br />
If the house address contains characters,<br />
that are not allowed in a tag name (*=. etc.),<br />
the conversion tool replaces them. If two<br />
house addresses only differ in one of these<br />
characters, the same tag name will be<br />
generated for both.<br />
=> change house addresses<br />
Change the csv-files before import into<br />
novaPro Open as followed:<br />
BmTLExport_Gate.csv:<br />
Write the number 4294967295 into the<br />
columns LoAlarm, LoLoAlarm, HiAlarm,<br />
HiHiAlarm.<br />
BmTLExport_Alar.csv:<br />
Write -1 into column RelTagId.<br />
2005/100_PHo<br />
2003/032_FER<br />
2003/033_FER<br />
2002/015_FER<br />
2002/009_SCP<br />
16. Jan 03 1.00 No export to ORACLE database through 1.11 Export works only with English operating 2002/034_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
ODBC system due to country specific separator.<br />
Solved with new WIZODBC.DLL, available<br />
16. Jan 03 1.00 No export to ORACLE database through<br />
ODBC between 12:00 and 13:00 (12:00<br />
and 1:00 PM)<br />
30. Aug 02 1.00 Data exchange with DDE<br />
novaPro Open as a DDE-Server and<br />
Microsoft Excel as DDE-Client<br />
7. Dongle<br />
08. Jul 05 1.12 USB Dongle not found or PC reports that<br />
the dongle was removed during normal<br />
operation.<br />
16. Jun 05 1.12 USB Dongle not found on some PCs, e.g.<br />
DELL Precision 370.<br />
Fr. Sauter <strong>AG</strong><br />
Seite 8 von 32<br />
wit V1.11.<br />
1.11 During this hour the entries have the wrong<br />
timestamp (12:xx AM). Solved with new<br />
WIZODBC.DLL, available wit V1.11.<br />
1. On your PDM start the program "DDE<br />
Server". It can be found on<br />
"Start/Programs/novaPro Open<br />
Suite/novaPro Open/DDE Server".<br />
2. Start Microsoft Excel<br />
3. In the cell you wand to exchange data<br />
with, please insert the formula as followed:<br />
='novaPro Open'|GATE!station:tag<br />
"station" stands for the station name (e.g.<br />
PDM1)<br />
"tag" stands for the tag name<br />
2.0 Please re-install the USB dongle driver.<br />
You may download the latest version from:<br />
http://www.aladdin.com/support/hasp/hasp4<br />
/vendor.asp<br />
Download HINSTALL V. 4.96 or later.<br />
Execute with the command line:<br />
Hinstall.exe - kp -i -cnt=yes -nomsg<br />
Check the BIOS setting as followed:<br />
Security / Execute Disable = OFF<br />
"Execute Disable Memory Protection<br />
2002/035_FER<br />
2002/020_SCP<br />
2005/098_FER<br />
2005/091_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
8. Drivers<br />
seit<br />
Version<br />
12. Feb 08 2.2 The new COV (Change Of Value) in the<br />
BACnet station is not more sent<br />
spontaneously.<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 9 von 32<br />
Technology" must be on OFF.<br />
3.0 The COV function is deactivated, if the<br />
value from COVRESUBSCRIBE, in the file<br />
VPIBCNxx.int, is greater then 3600.<br />
Solution:<br />
Set COVRESUBSCRIBE less then 3600.<br />
2008/001_TAM<br />
05. Jul 05 1.00 Where can I find the latest driver list? Please find the list at:<br />
http://support.axeda.fr<br />
2005/094_FER<br />
12. Jan 05 VPIWNS24: Communication problems with<br />
By adding the parameter MODEM to 2005/079_FER<br />
Netcom<br />
VPIWNS24*.INT you may adapt the timing<br />
to Netcom.<br />
17. Nov 04 1.12 SP1 BACnet driver fails (size of driver files<br />
You have to replace the two faulty files 2004/075_PHo<br />
vpiwnBAC.dll and WizBACnetGen.dll is<br />
(vpiwnBAC.dll and WizBACnetGen.dll).<br />
very small)<br />
Available from Support SBA<br />
02. Aug 04 No Communication if less than 7 tags. You have to have at least 7 tags specified<br />
to get communication over the vpis36<br />
driver.<br />
2004/072_PHo<br />
12. Mai 04 1.12 Can we do calendar functions with<br />
ZP2400 does not support a calendar, but 2004/069_SCP<br />
ZP2400?<br />
there is a solution how a calendar function<br />
can be build with EY2400:<br />
Use novaScheduler<br />
Send the day replacement code to the<br />
substation with address !T<br />
The telegram is: P???40D@---7/ ,<br />
Configure it as an Actions of<br />
novaScheduler.<br />
Like this replacement days can be set.<br />
1 is Monday ... 6 is Saturday, 7 is Sunday.<br />
Make sure this telegram is sent after<br />
midnight.<br />
16. Mrz 04 1.00 BACnet: nPO does not find all BACnet Probably the settings of the BACstac 2004/063_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
servers protocol stack are incorrect.<br />
Please check:<br />
- that you use the same protocol as the<br />
server<br />
- if the subnet mask from the BACstac<br />
properties matches the mask from your<br />
network<br />
- that the BBMD is configured, if client and<br />
16. Mrz 04 1.00 BACnet: nPO does not find BACnet servers<br />
from other subnets, although BBMD is<br />
configured<br />
16. Mrz 04 1.00 BACnet: nPO does only sees Device object<br />
from a server.<br />
13. Okt 03 BACnet: Unable to select BACnet driver in<br />
project<br />
13. Okt 03 BACnet: Installation files for BACnet<br />
protocol are missing<br />
Fr. Sauter <strong>AG</strong><br />
Seite 10 von 32<br />
server are in different subnets.<br />
In the settings for the BBMD, the subnet<br />
mask of the remote BBMD must always be<br />
255.255.255.255<br />
a) The device has no other object, or<br />
b) The device does not support the protocol<br />
configured in BACstac.<br />
Run the novaPro Open setup program,<br />
chose "Custom Installation", add the<br />
BACnet driver. It is not enough to copy the<br />
DLLs to the BIN directory!<br />
The installation files should be in the folder<br />
"Bin\BACnet Install". If not, run the novaPro<br />
Open setup program, chose "Custom<br />
Installation", add the BACnet driver.<br />
The driver needs a valid ini file to be able to<br />
finish the setup<br />
31. Jan 03 1.00 M-Bus: novaPro Open crashes after setting<br />
up the M-Bus driver.<br />
27. Jan 03 1.00 Driver does not work in demo mode Demo mode for licensed drivers only works<br />
without a dongle.<br />
9. Error Messages<br />
11. Jul 06 2.10 "Initialisation of logger failed" This message is caused by big files of type<br />
LANG0000.*. It's a Time-Out of the<br />
initialisation. The default value is 2<br />
minutes. Add the parameter as followed to<br />
wiztune.dat:<br />
2004/064_FER<br />
2004/065_FER<br />
2003/050_FER<br />
2003/051_FER<br />
2003/040_FER<br />
2003/038_FER<br />
2006/118_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
05. Feb 05 1.12SR2 Error messages like "Could not find entry<br />
point for xyz.DLL" when launching novaPro<br />
Open after installing Sauter Components<br />
26. Mrz 04 1.00 On network drives, you get error message<br />
"Disk is more than xx% full. History will be<br />
deleted", even if there is sufficient space.<br />
27. Feb 04 "novaPro Open did an illegal operation",<br />
"novaPro Open generated an exception"<br />
27. Feb 04 "novaPro Open did an illegal operation",<br />
"novaPro Open generated an exception",<br />
generated by OPC server "OPCLONVNI"<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 11 von 32<br />
LOGGER_TIMEOUT=10<br />
Sauter Components installs a patch. If SR2<br />
was installed before of the Sauter<br />
Components, the newer files from SR2<br />
were overwritten by the older files from<br />
Sauter Components.<br />
Please install as follows:<br />
1.) Install nPO<br />
2.) Install Sauter Components.<br />
3.) Install latest Patch<br />
You can use the tuning parameter<br />
"WIL_DISK_HIGH_LIMIT" to define the limit<br />
(in %), from when novaPro Open should<br />
start deleting history files.<br />
Network drives need special attention,<br />
since their size may be limited by the<br />
administrator. For example, if a 1 GB<br />
network drive is on a 40 GB hard drive, the<br />
operating system will return, that 1GB of 40<br />
GB is free (= 2.5%), and novaPro Open will<br />
start to delete the history files, since the<br />
default limit is 97%.<br />
The error may have been originated by any<br />
process or thread of novaPro Open.<br />
To find out which, please look in errors dat<br />
for the thread that caused the error. You<br />
can identify it by the numbers in brackets,<br />
eg. (1696:2372), and look up for the<br />
process name.<br />
The copy protection is defective. Please<br />
contact SBA to fix.<br />
2005/080_FER<br />
2004/066_FER<br />
2004/058_FER<br />
ECR1770_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
27. Feb 04 "novaPro Open did an illegal operation",<br />
"novaPro Open generated an exception"<br />
generated during shutdown by MBS<br />
BACnet OPC server<br />
27. Feb 04 "novaPro Open did an illegal operation",<br />
"novaPro Open generated an exception"<br />
generated during loading of tag history by<br />
VFI5FST.<br />
27. Feb 04 "novaPro Open did an illegal operation",<br />
"novaPro Open generated an exception"<br />
generated during shut down by<br />
CL_HARDCOPY<br />
13. Okt 03 BACnet driver: "Communication driver<br />
validity test failed" when starting novaPro<br />
Open.<br />
13. Okt 03 Error messages when writing 0 in some<br />
tags; driver tries to write -1.14E-38 instead<br />
of 0<br />
17. Jan 03 1.00 Error message "Wizpro client did an illegal<br />
operation". Entry in errors.dat, that wizcon<br />
language caused the illegal operation.<br />
17. Jan 03 1.00 novaPro Open crashes when running as a<br />
web server. Error message in errors.dat:<br />
Exception error from INETSERV.EXE<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 12 von 32<br />
1.11 The OPC server does not shutdown<br />
correctly. After a timeout nPO generates<br />
this error message.<br />
This error message is not critical.<br />
In nPO 1.11 novaPro Open continues the<br />
shutdown without an error message.<br />
Est. 1.12 A file of the tag history is corrupted.<br />
Please contact SBA.<br />
CL_HARDCOPY is a third party add-on,<br />
that does not belong to the novaPro Open<br />
Suite.<br />
No support information available for this<br />
program.<br />
a) driver is not activated on the dongle<br />
b) BACnet-Protocol is not installed.<br />
Please refer to drivers help file, chapter<br />
"Notes". The files for the installation are in<br />
"...\novaPro Open\Bin\BACnet install"<br />
The value 0 can not be coded exactly as 0<br />
in the float format.<br />
The tuning parameter<br />
WIZPRO_VPI_ROUND=YES in the<br />
WIZTUNE.DAT will round the value, so that<br />
no more error messages are displayed..<br />
2004/059_FER<br />
2004/060_FER<br />
2004/061_FER<br />
2003/048_FER<br />
2004/057_FER<br />
novaPro Open language was launched<br />
twice: in the application setup and in the<br />
settings of novaPro Open language. It may<br />
only be started once.<br />
2002/036_FER<br />
1.11 Fixed with new version of INETSERV.EXE 2002/037_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
10. General<br />
seit<br />
Version<br />
25.July.08 2.2 After a crash (blue screen) occurred during<br />
a burning session on Nero (Back Up), the<br />
operation of novaPro Open is very slow<br />
(pictures take several minutes to open).<br />
25.July.08 2.2 Audit trail process fills C: with big tmp files<br />
(100 Mo and higher) – CPU steady<br />
overloaded because of WizAT.dll.<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 13 von 32<br />
Delete Wizretain.dat file.<br />
„init retain fails „ entries in Errors.dat shows,<br />
that the errors is originated by the damaged<br />
Wizretain.dat.<br />
A new WizAT.dll fixes the problem. This<br />
new WizAT.dll is to be installed in the folder<br />
novaProOpen\bin. Dll is available from the<br />
support untill this willl be released in a<br />
Patch.<br />
29 Avril 08 Log files are filling to fast new Using EMM_UI.exe tool will fix this isue<br />
18. Aug 06 novaPro Open crashes on log on/log off or<br />
when loading a layout.<br />
18. Aug 06 novaPro Open crashes on start up or when<br />
adding the driver VPIWNS36.<br />
25. Jan 06 How can I set the priority for executing<br />
novaPro Open?<br />
nPO 2.1 SP1<br />
Patch 38 with<br />
Sauter<br />
Components<br />
Please ask the support team from Basle for<br />
a macro that works around this problem.<br />
Please refer to IRM 4395.<br />
This may happen if no nova291 is attached<br />
to the COM port. Please install SP1, Patch<br />
38 and the Sauter Components.<br />
When using the Sauter drivers, the Sauter<br />
Components must be always installed.<br />
You may use the freeware tool "PRN<br />
Process Priority Saver" to assign a priority<br />
to every novaPro Open process<br />
(www.prnwatch.com/prio.html)<br />
25. Jan 06 Can you run novaPro Open as a service? No.<br />
There are tools available to run any<br />
program as a service, but SBA gives no<br />
20. Dez 05 2.00 The OPC AE Client remains invisible. Only<br />
an icon is displayed in the info area from<br />
the task bar.<br />
warranty or support.<br />
You can control the behaviour by setting<br />
the WIZTUNE-Parameter<br />
"OPCAE_HMICLI_VISIBLE=TRUE".<br />
Please note that "YES" will not work!<br />
2008/002_GEA<br />
2008/003_GEA<br />
2006/128_FER<br />
2006/129_FER<br />
2006/109_FER<br />
2006/111_FER<br />
2005/108_FER<br />
01. Mrz 05 1.00 nPO takes very long to launch 1.0 errors and errors.dat may become very big. 2005/081_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
01. Mrz 05 Popup on start of application:<br />
"Are you sure that you want to enable the<br />
advanced information mode?"<br />
05. Nov 03 1.00 After a moving a project (Copying to/from<br />
CD), the project cannot be opened<br />
anymore. An error message indicates<br />
"Codebase Error:...".<br />
09. Okt 03 1.11 When working with nPO on new Server<br />
PCs with XEON processors with hyper<br />
threading mode (e.g. Dell Power Edge<br />
1600) it regularly crashes (especially when<br />
closing pictures).<br />
17. Feb 02 1.00 Stop novaPro Open through a DOS-shell<br />
command or Macro<br />
11. Images<br />
18. Aug 06 novaPro Open crashes after editing a<br />
clusters properties<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 14 von 32<br />
Please check the size and, if necessary,<br />
limit it in the station properties.<br />
This means, that the Advanced information<br />
mode is set for the log viewer.<br />
It may be disabled in the menu from the<br />
studio "Tools->View Log file"<br />
Data which has been copied from a CD is<br />
write protected. To start the nPO project the<br />
write protection has to be taken off.<br />
2.0 Deactivate the hyper threading mode in the<br />
BIOS setup. CPU Information: Logical<br />
Processor = Disabled.<br />
1.0 Command to stop novaPro Open through<br />
DOS window:<br />
Wizpro /s<br />
Macro: Create a Macro with Command<br />
"Wizpro /s".<br />
nPO 2.1 SP1<br />
Patch 38 with<br />
Sauter<br />
Components<br />
2005/082_FER<br />
2003/055_PHo<br />
2003/047_PHo<br />
2002/022_SCP<br />
Fixed with Version 2.1 SP1 Patch 38 2006/131_FER<br />
11. Jul 06 2.10 Rendering problem with text Add the parameter as followed to<br />
Wiztune.dat:<br />
IMG_EXPAND_REFRESH_BOX=10<br />
Default value: 2<br />
min: 0<br />
max: 20<br />
After adding or changing this parameter a<br />
restart of novaPro Open is required.<br />
2206/1119_SC<br />
P
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
22. Jul 05 2.00 Images are distorted on screen with width- 2.0 Go to Studio and open image properties 2005/099_SCP<br />
to-height-ratio of 16:9. Circles are shown as<br />
and go to tap "Loading". Set the tick box<br />
ellipses.<br />
"Disable automatic calibration of new<br />
images" and selects screen format 16:9.<br />
20. Mrz 05 How can I define a trigger to toggle a digital<br />
tag?<br />
Use an action trigger with the formula "1-@" 2005/090_FER<br />
07. Feb 02 1.00 All objects of an image become invisible<br />
after you left editing mode.<br />
07. Feb 02 1.00 The command "Undo" does not work<br />
correctly.<br />
07. Feb 02 1.00 When you define a cluster with alarm<br />
objects, the "$ASK" command can not be<br />
used to display a dialog that asks for the<br />
Alarm family at the time you open this<br />
cluster in an image.<br />
12. Installation<br />
Fr. Sauter <strong>AG</strong><br />
Seite 15 von 32<br />
The user, who logged in last has no access<br />
right for the layers displayed. Go to the<br />
menu "Layers" in your image, open<br />
"Definition" and assign access right for the<br />
layers used. Please make sure that at least<br />
one or all users get access right for layer<br />
"BASE".<br />
Do not use the "Undo" command after<br />
operations as followed:<br />
Alignment<br />
1.1 Known error, that will be fixed in one of the<br />
next releases of novaPro Open.<br />
Work around:<br />
Assign a dummy alarm family to the cluster.<br />
After selecting a cluster from the library, go<br />
to the properties of the cluster (right mouse<br />
button) and exchange the dummy alarm<br />
family by the alarm family you want to<br />
assign to the alarm object.<br />
20. Dez 05 2.00 The OPC AE client is missing. The OPC AE client is not installed<br />
automatically.<br />
Run the custom setup and select the OPC<br />
2002/001_SCP<br />
2002/003_SCP<br />
2002/006_SCP<br />
2005/107_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
19. Okt 05 2.00 Instead of the driver's version vpiwins36<br />
V4.9.17 from 17.09.2004 (which is actually<br />
the valid version) the driver's version<br />
vpiwins36 V4.2.11 from 23.03.2004 is<br />
installed.<br />
05. Mrz 04 1.00 It is not possible to uninstall novaPro Open.<br />
When trying to uninstall, a window pos up<br />
telling that a previous version was detected<br />
and that it should be uninstalled with "Add<br />
and remove programs" from the control<br />
panel.<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 16 von 32<br />
components.<br />
Uncheck the option "Driver" In the section<br />
"Install Sauter Components" in the<br />
installation menu of the CD2.<br />
1.) Delete folder ...\Programme\Install<br />
Shield Installation Information\{5583E600-<br />
68ED-11D2-A71A-0060972F421F}<br />
2.) Delete these keys from the registry:<br />
- Axeda Supervisor<br />
- {004231F0-E58F-11d0-9449-<br />
000000000000}<br />
- {2C63C178-E9DB-4AC5-99D0-<br />
3A91F04A13E2}<br />
- {CA160C61-FA27-11D4-AA06-<br />
005004FE87C6}<br />
- {004231F0-E58F-11d0-9449-<br />
000000000000}<br />
- eMation.WebSchClient<br />
- eMation.WebSchServer<br />
- eMation.Wizcon<br />
- HKEY_LOCAL_MACHINE\<br />
SOFTWARE\emation<br />
-<br />
HKEY_CLASSES_ROOT\Applications\Wizc<br />
on.EXE<br />
-<br />
HKEY_CLASSES_ROOT\Applications\WIZ<br />
PLC.EXE<br />
2005/1822_SJ<br />
2004/062_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
27. Feb 02 1.00 novaPro Open can not be deinstalled any<br />
more after you enabled "System Security"<br />
in the installation dialog.<br />
07. Feb 02 1.00 On PCs where the software EY3600 CASE<br />
FBD or novaPro32 has been installed, a<br />
dialog to select a Workbench (*.DEW)<br />
shows up when you try to start a novaPro<br />
Open project.<br />
13. Network<br />
18. Aug 06 Network communication errors freeze the<br />
PC<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 17 von 32<br />
- HKEY_CLASSES_ROOT\novaPLC<br />
Application File<br />
- HKEY_CLASSES_ROOT\novaPro Open<br />
Application File<br />
-<br />
HKEY_LOCAL_MACHINE\SOFTWARE\Mi<br />
crosoft\Windows\CurrentVersion\App<br />
Paths\Wizcon.Exe<br />
-<br />
HKEY_LOCAL_MACHINE\SOFTWARE\Mi<br />
crosoft\Windows\CurrentVersion\App<br />
Paths\Wizplc.exe<br />
HKEY_LOCAL_MACHINE\SOFTWARE\Mi<br />
crosoft\Windows\CurrentVersion\Uninstall\{<br />
5583E600-68ED-11D2-A71A-<br />
0060972F421F}<br />
Open regedit.exe of Windows and delete<br />
"GinaDLL = WIZGINA.DLL" in<br />
HKEY_LOCAL_MACHINE\Software\Micros<br />
oft\Windows<br />
NT\CurrentVersion\WINLOGON.<br />
1.1 Deinstall novaPro Open.<br />
Restart the installation and replace the<br />
spaces in the default installation path by<br />
any other character, e.g. _ (underline).<br />
This problem is known from some<br />
embedded network adapters. It is caused<br />
by a network problem and not by novaPro<br />
Open.<br />
2002/007_SCP<br />
2002/004_SCP<br />
2006/133_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
15. Mrz 02 1.00 novaPro Open Network and firewall resp.<br />
router: Which TCP-Ports are used?<br />
14. novaPLC<br />
03. Okt 06 "2.0/<br />
Codesys<br />
2.3<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Communication error when going online<br />
after the project was moved to a different<br />
folder<br />
24. Feb 03 1.10 Online help can not be opened in novaPLC<br />
Development.<br />
Fr. Sauter <strong>AG</strong><br />
Seite 18 von 32<br />
Resolution: please check the wiring of the<br />
network. Take special care of potential<br />
differences. Using a network adapter card<br />
instead of the embedded network adapter<br />
may also solve the problem.<br />
3025 UDP - broadcast receiver<br />
3024 TCP - Listen prot for station's<br />
connection<br />
3026 TCP - Listen prot for broadcast<br />
to/from another subnet (othernet.dat)<br />
3028 TCP - Internet Server<br />
Dynamic filtering of answers for ports<br />
higher 1024 seems not to work with<br />
novaPro Open Network. The router has to<br />
be configured without dynamic filtering, so<br />
that all answers can pass.<br />
In the novaPLC Development Studio open<br />
the menu "Online -> Communication<br />
Parameters" and select "Local -PLCWinNT"<br />
1.12 Open the file C:\Program<br />
Files\Sauter\EY3600\novaPro_Open<br />
Suite\novaPLC\Help\novaPLC.CNT with an<br />
editor.<br />
Replace WizPLC.hlp by novaPLC.hlp in the<br />
first line.<br />
2002/008_SCP<br />
2006/139_FER<br />
2003/042_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
15. Product quality of novaPro Open<br />
16. Aug 06 Representation problems at upgrades on<br />
new program releases (Backward<br />
compatibility)<br />
16. Aug 06 Option "Backup User" not works in<br />
"Advanced Alarm Management"<br />
16. Reports<br />
04. Apr 02 1 The "Rep" or "Report" function only<br />
produce empty report files.<br />
17. Tags<br />
27. Jul 06 2.10 CSV-files created with a previoous release<br />
can not be imported.<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 19 von 32<br />
See current product information on extranet<br />
& installation-CD<br />
2006/137_TAM<br />
Still open 2006/138_TAM<br />
Rep only works, if the file and path name<br />
are named according to DOS file naming<br />
rules (no blanks, 8.3 characters) => Path to<br />
the project folder must be named according<br />
to these rules<br />
A CSV-file for release 2.1SP1 must contain<br />
the columns as followed: (new columns in<br />
red)<br />
Rec No, Gate Name, Description,<br />
Groups, Rec, Rate, DDE, DDE I/A,<br />
App, Topic, Item, Source, VPI,<br />
Address, Sample, Rate, Compound<br />
I/A, K1, Gate1, Op, K2, Gate2,<br />
Type, Fmt, Tol/Fil/Len, X1, X2, Y1,<br />
Y2, Low, High, RO, ODBC, Local,<br />
Lock, LockDef, Replay, TagMapper,<br />
StartupDef, StartupHis,<br />
StartupRetain, LockValue,<br />
StatusTag, UnlockTime, LoAlarm,<br />
LoLoAlarm, HiAlarm, HiHiAlarm,<br />
RocAlarm, DevAlarm, StartupValue,<br />
ExportToWizPlc, VarName, IO,<br />
Address, Sampling, NoSampling,<br />
Retain, ReadOnly, InitBy<br />
2002/012_FER<br />
2006/121_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
08. Jul 05 After restarting nPO, locked tags are not<br />
Workaround: if the network is active, this 2005/097_FER<br />
locked any more.<br />
problem does not show up.<br />
06. Jul 05 1.12 The novaPro Open project can not be 1.1 Deactivate in the clock settings of Microsoft 2002/002_SCP<br />
started any more after import of a tag list<br />
Windows the automatic adjustment to<br />
using a CSV-file.<br />
daylight saving time.<br />
27. Okt 04 Error message "Failed to write tag value.<br />
In the tag definition, be sure to have the 2004/074_FER<br />
Value out of limits" when writing into tag.<br />
correct tag limits and conversion.<br />
The default conversion is:<br />
Value1: 0 measured 0 displayed<br />
Value2: 1 measured 1 displayed<br />
11. Feb 03 1.00 What special characters can be used in tag<br />
Tag names must not contain any special 2003/041_SCP<br />
names?<br />
characters, except _ (underscore).<br />
Tag names should always begin with a<br />
letter and must not contain two or more<br />
underscore in sequence.<br />
Tag names beginning with a digit can not<br />
be accessed from novaPLC.<br />
22. Jan 03 1.00 When importing EY2400-Tags, you get an<br />
Check your tag names. Maximum 31 2003/025_SCP<br />
error message "...Description Delimiters<br />
characters are allowed for a tag name.<br />
()".<br />
Change all tag names that containing more<br />
than 31 characters. But make sure that<br />
every tag name is unique.<br />
12. Apr 02 1.00 The novaPro Open project can not be<br />
Open the file WIZDATA.MDB of your 2002/014_SCP<br />
started any more after import of a tag list<br />
project (Access 2000 needed).<br />
using a CSV-file.<br />
Open table "Tags".<br />
Make sure, all dates in column "Unlock<br />
Time" are newer than 1980.<br />
07. Feb 02 1.00 The novaPro Open project can not be 1.1 Deactivate in the clock settings of Microsoft 2002/002_SCP<br />
started any more after import of a tag list<br />
Windows the automatic adjustment to<br />
using a CSV-file.<br />
daylight saving time.<br />
18. User Management<br />
15. Dez 04 1.12 Synchronisation of local User Management<br />
database with Central User Management<br />
Fr. Sauter <strong>AG</strong><br />
Seite 20 von 32<br />
At start-up, nPO updates the version of the<br />
default WizUM database that holds the<br />
2004/077_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
database does not work after updating to<br />
V1.12 SP2.<br />
29. Nov 04 1.12SP2 Central User Management does not<br />
synchronize with local WizUM.mdb<br />
Fr. Sauter <strong>AG</strong><br />
Seite 21 von 32<br />
User Configuration.<br />
If nPO is configured to connect to the<br />
Centralized User Management Databases<br />
(based on MSSQL2000) by default, only<br />
this databases will be updated.<br />
To synchronize the central and the local<br />
databases, both versions of the central and<br />
local databases must match. Central<br />
Databases will not synchronize with the<br />
local databases if versions are not identical.<br />
To upgrade a local User Management<br />
databases (based on Access 2000) at startup,<br />
nPO must be configured to use the local<br />
database by default. Upgrade will<br />
automatically be done at start-up, if nPO<br />
detects that the default User Management<br />
database is in an old version.<br />
To verify the actual version of the default<br />
databases, you can open WizUM.log in<br />
your project folder after start-up.<br />
Two queries have to be added to local<br />
WizUm.mdb. Proceed as followed:<br />
1. Open WizUM.mdb with Access 2000 or<br />
XP, password "WizFactory3"<br />
2. Select "Queries"<br />
3. Select "New"<br />
4. Select "SimpleQueryWizard" in window<br />
"New Query"<br />
5. In window "SimpleQueryWizard", in field<br />
"Tables/Queries" select<br />
"Table:UM_Version_T"<br />
6. Select "Version" in the field below and<br />
2004/076_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
04. Mai 04 1.12 Installation of Central User Management<br />
with MSDE (Microsoft SQL Server 2000<br />
Desktop Engine) Release A<br />
04. Mai 04 1.12<br />
1. Download from<br />
www.microsoft.com/sql/msde<br />
Installation of Central User Management<br />
with MSDE (Microsoft SQL Server 2000<br />
Desktop Engine) Release A<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
2. Installation of MSDE on the central fileserver<br />
that hosts the Central User<br />
Management<br />
04. Mai 04 1.12 Installation of Central User Management<br />
with MSDE (Microsoft SQL Server 2000<br />
Desktop Engine) Release A<br />
Fr. Sauter <strong>AG</strong><br />
Seite 22 von 32<br />
click on the arrow to the right. Now,<br />
"Version" can be found under "Selected<br />
Fields"<br />
7. Click on "Next"<br />
8. In window "Simple Query Wizard" select<br />
"Detail" and click "Next"<br />
9. Name this query<br />
"UM_CleanUnusedData1_Q" and click<br />
"Finish.<br />
10. Repeat step 2 to 9 and create a query<br />
named "UM_CleanUnusedData2_Q"<br />
11. Save WizUM.mdb and close it.<br />
1. Download MSDE 2000 Release A<br />
(MSDE2000A.exe)<br />
2. Download SQL Server Web Data<br />
Administrator<br />
1. Execute MSDE2000A.exe<br />
The file unpacks and creates the install<br />
files on C:\MSDERelA<br />
2. Open a DOS command window:<br />
Start/Run../CMD<br />
3. Select folder: CD C:\MSDErelA<br />
4. Start installation with<br />
setup.exe<br />
DISABLENETWORKPROTOCOLS=0<br />
SECURITYMODEE=SQL<br />
SAPWD="sa"<br />
5. The folder C:\MSDERelA may be<br />
removed after installation<br />
1. Run setup.msi<br />
2. Run Internet Services Manager<br />
3. Go to the virtual folder "webadmin" of IIS,<br />
2004/067_SCP<br />
2004/067_SCP<br />
2004/067_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
3. Installation of SQL Server Web Data<br />
Administrator on the central file-server that<br />
hosts the Central User Management<br />
04. Mai 04 1.12 Installation of Central User Management<br />
with MSDE (Microsoft SQL Server 2000<br />
Desktop Engine) Release A<br />
19. VPIWNS36 (Driver EY3600)<br />
4. Setup of the central Database<br />
18. Aug 06 The communication gets slow and<br />
unreliable with more than 4800 EY3600<br />
tags on one novaNet.<br />
11. Jul 06 May I use a device server (COM server) to<br />
connect the 291 to the PDM?<br />
nPO 2.1 SP1 P38<br />
+ Sauter<br />
Components<br />
Fr. Sauter <strong>AG</strong><br />
Seite 23 von 32<br />
tap "Directory Security" - Edit - activate<br />
"Integrated Windows authentication"<br />
1. Copy the files WizUM.mdf and WizUM.ldf<br />
from C:\Program<br />
Files\Sauter\EY3600\novaPro_Open<br />
Suite\novaPro Open\Bin\NewWizApp to the<br />
central file-Server hosting the central User<br />
Management.<br />
2. Create an ASCII-file with extension *.sql<br />
on the central file server, with content as<br />
followed:<br />
/* Attach Data Base */<br />
EXEC sp_attach_db @dbname=N'WizUM',<br />
@filename1=N'path\WizUM.mdf',<br />
@filename2=N'path\WizUM.ldf'<br />
3. Run SQL Web Data Administrator<br />
Username: SA<br />
Password: sa<br />
Authentication Method: SQL Login<br />
4. Select Import *.sql-Datei<br />
5. Select "Microsoft SQL Server" for user<br />
management in Station Properties of your<br />
novaPro Open application.<br />
2004/067_SCP<br />
Please use driver version 6.6.1.0 or higher 2006/134_FER<br />
Use EYZ292.<br />
No support for other Device Servers from<br />
2006/115_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
11. Jul 06 2.1SP1 STATION_INIT_DELAY<br />
SBA.<br />
When initializing automations stations<br />
(subscription of MFAs) the driver makes a<br />
delay after each 32 telegrams in order to<br />
keep the bus clear for the answers of the<br />
AS. With help of this parameter the bus can<br />
be optimized in the initialization phase. The<br />
default setting is 3s. In heavily loaded<br />
novaNets, e.g. with multiple PCs this<br />
parameter has to be increased.<br />
Entry in file vpis3601.int:<br />
2006/116_SCP<br />
14. Apr 05 1.00 Driver does not resubscribe data points<br />
after power failure in the AS<br />
25. Feb 04 1.00 S36 driver does not start correctly, if<br />
initialisation of other drivers takes too long<br />
(> 5 minutes)<br />
22. Jan 03 1.00 How can I visualize state "Auto" of a<br />
functional block AIA-Soft or AO in novaPro<br />
Open?<br />
expected<br />
1.12<br />
Fr. Sauter <strong>AG</strong><br />
Seite 24 von 32<br />
STATION_INIT_DELAY = 5<br />
The status tag $ST needs to be defined, so<br />
the driver can see, if the AS is offline or<br />
online.<br />
Please see the Integration Handbook<br />
EY2400/EY3600 (7001011) for details<br />
Since VPIWNS36 V. 4.2.11, the<br />
initialisation timeout can be tuned in the<br />
driver initialisation file.<br />
This version is available at SBA upon<br />
request.<br />
Create a tag with type DA for the same<br />
MFA as function block AIA or AO. Use tag<br />
type NDA for AOs of novaLink modules.<br />
Example: Address: 001:1_22_DA<br />
Please note: This tag has only to be defined<br />
associated to a defined AO tag.<br />
(Solution for V1.0 to V2.0:<br />
Modify the FBD of the corresponding AS as<br />
followed:<br />
1. Connect output Y of the functional block<br />
2003/091_FER<br />
2004/058_FER<br />
2006/117_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
20. Web<br />
seit<br />
Version<br />
02. Feb 06 Web-Application interrupts the network<br />
connection on Toshiba notebooks of the<br />
series S1 and S2<br />
17. Nov 05 When jumping from an event summary to<br />
an image with the "Go to zone" button, only<br />
a part of the image is displayed.<br />
22. Sep 05 1.12 Static text objects are displayed in a wrong<br />
size (Very big)<br />
22. Sep 05 1.12 String tags and text tables are displayed in<br />
a wrong size (Very big)<br />
09. Mrz 05 Error message "Maximum number of clients<br />
reached", although only one web client is<br />
connected to the nPO web server<br />
04. Mrz 05 1.12 After some navigation through the web<br />
SR2 images, the tags only show *****.<br />
It is necessary to restart the web browser.<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Fr. Sauter <strong>AG</strong><br />
Seite 25 von 32<br />
AIA-Soft with the input of a DW_F32.<br />
2. Connect output fC3 of the DW_F32 to<br />
the input of a BI_Soft.<br />
3. Assign a house address to the BI_Soft.<br />
4. This BI_Soft can be mapped to a<br />
novaPro Open tag of type Digital. The tag<br />
will show logical 0 for "AUTO" and logical 1<br />
for "Man".)<br />
The driver of the network card has a bug.<br />
You may download a good one from<br />
http://www.marvell.com/products/pcconn/yu<br />
kon/index.jsp.<br />
Beware: the driver available at the website<br />
of Toshiba does not work either.<br />
2006/112_FER<br />
When navigating from an event summary to<br />
an image, the image opens with the<br />
settings from "Template.HTML". These may<br />
vary from the initial [Imagename].HTML.<br />
Open Template.HTML with a text editor and<br />
set the parameters "WIDTH" and "HEIGHT"<br />
to the same values as in the original<br />
[Imagename].HTML<br />
2005/103_FER<br />
1.12 SR2 Fixed with SR2 2005/104_FER<br />
Patch in development. 2005/105_FER<br />
Please update Java classes using the<br />
Application upgrade utility<br />
Please ask SBA for Hotfix 131, which<br />
solves this problem.<br />
2005/087_FER<br />
2005/084_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
01. Mrz 05 Tagmapper tags show **** in the web The image must contain an object with the<br />
tag WIZTGM_INDEX<br />
2005/083_FER<br />
28. Jun 04 1.12SP1 Replacement of fonts in Web images In web images fonts are replaced as<br />
followed:<br />
JDK 1.1.8 (MS JVM):<br />
Windows Arial => Helvetica<br />
Windows Modern => Symbol<br />
Win. Times New Roman => Times Roman<br />
Windows Courier => Courier<br />
Windows System => Dialog<br />
JDK 1.4.2_03+ (Sun Java VM):<br />
Windows Arial => Arial<br />
Windows Modern => Symbol<br />
Win. Times New Roman => Times Roman<br />
Windows Courier => Courier<br />
Windows System => Dialog<br />
2004/071_SCP<br />
13. Okt 03 The event summary is not displayed<br />
Disable Hyper threading Mode in the BIOS 2003/052_FER<br />
correctly in the web (blank zones in the<br />
Setup of the client. CPU Information:<br />
screen, wrong colours)<br />
Logical Processor = Disabled.<br />
13. Okt 03 1.11 It is not possible to assign a value to a text<br />
gate with a trigger on the web.<br />
1.12 Update Java Classes 2003/056_FER<br />
13. Okt 03 Not possible to log in a) Port 3028 is disabled on the firewall<br />
b) The application must not be on a<br />
compressed NTFS directory.<br />
c) The user has insufficient NTFS<br />
authorisation for the DOCS directory and its<br />
files.<br />
10. Sep 03 1.11 Change image with fast action trigger<br />
"LOAD IM<strong>AG</strong>E" opens always a new Webbrowser<br />
window.<br />
Fr. Sauter <strong>AG</strong><br />
Seite 26 von 32<br />
Add the parameter as followed to<br />
Wiztune.dat:<br />
LOAD_IM<strong>AG</strong>E_SAME_WIN=YES<br />
From now on, a new image is opened in the<br />
already open browser window.<br />
2003/054_FER<br />
2003/046_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
20. Jan 03 1.00 Is there a time-out function which will<br />
Modify your HTML-file as followed: Add 2003/023_SCP<br />
automatically logout a user after a<br />
after the line<br />
predefined time?<br />
<br />
16. Jan 03 1.00 Web client freezes on tag inhibit 1.11<br />
filename.html has to be a plane HTML-<br />
Web-page (no novaPro Open image).<br />
With this setting the Web-page is<br />
automatically redirected after 360 seconds<br />
to filename.html and the Web license used<br />
by the user is released for others.<br />
New WIZINTSERV.DLL solves problem<br />
16. Jan 03 1.00 Tag inhibit window displays "Error Error" in<br />
the two upper lines<br />
Fr. Sauter <strong>AG</strong><br />
Seite 27 von 32<br />
(available with version 1.11)<br />
1.11 User rights are insufficient for inhibiting all<br />
the tags.<br />
Fixed in Version 1.11.<br />
16. Aug 02 1.00 Text is not displayed correctly on the web Use True Type fonts.<br />
Recommended Fonts: Arial, Times New<br />
Roman, David. Minimal size 5 pt.<br />
Do not resize text objects.<br />
16. Aug 02 1.00 BMP images are displayed with a poor<br />
quality on the web.<br />
16. Aug 02 1.00 Can TCP Port 3028 be changed<br />
(communication in the Web)?<br />
03. Apr 02 1.00 When trying to open a web document the<br />
internet explorer shows error message<br />
"HTTP 401.2 - Unauthorized: Logon failed<br />
due to server configuration"<br />
Internet Information Services" or "You are<br />
Use styles for formatting text.<br />
BMPs are converted to JPG with the<br />
highest compression by default.<br />
For a better quality convert BMPs manually<br />
to JPG with the wanted compression.<br />
1.1 In novaPro Open 1.0 the port address can<br />
not be changed. From next release of<br />
novaPro Open 1.1 this port address can be<br />
changed.<br />
1.0 The web server tries to authenticate the<br />
user with the windows login. This is not<br />
supported by the proxy.<br />
If client an server are in the intranet:<br />
declare the web server address as a local<br />
2003/030_FER<br />
2003/031_FER<br />
2002/016_FER<br />
2002/017_FER<br />
2002/019_SCP<br />
2002/010_FER
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
not authorized to view this page" or similar<br />
messages<br />
03. Apr 02 1.00 Alarm objects are not always visible in the<br />
web.<br />
21. Web Scheduler<br />
20. Dez 05 2.00 After login, the left frame shows the HTTP<br />
error message: "BACnet ASP Object is Null<br />
or not an object<br />
/Webscheduler/Outlookbar/Outlook.ASP<br />
Line 7"<br />
28. Feb 03 1.10 novaScheduler can not be opened from a<br />
network operating station or Web-Client. An<br />
error message "Compilation error in<br />
1.1<br />
address (Internet Explorer->Tools->Internet<br />
Options->Connections->LAN Settings-<br />
>Advanced->Exceptions)<br />
If internet access is planned: Check<br />
"Anonymous access" in the properties of<br />
the Virtual Web directory->Directory<br />
Security->Edit Anonymous access and<br />
anonymous access".<br />
Use Java Classes from SP2 for nPO 1.0 2002/011_FER<br />
Fr. Sauter <strong>AG</strong><br />
Seite 28 von 32<br />
The BACnet scheduler from nPO 2.0 needs<br />
the BACstac BACnet protocol stack 4.2.<br />
The problem is originated by an incomplete<br />
upgrade from older versions of the<br />
BACstac.<br />
Solution:<br />
1.) Uninstall BACstac manually from the<br />
network icon from the control panel<br />
2.) Delete manually all BACnet-DLLs<br />
(BAC*.DLL) from WINNT/System32.<br />
You might need to reboot the PC to delete<br />
them.<br />
3.) Re-install BACstac.<br />
4.) Register<br />
novaScheduler/Bin/BACnetASPSrvr.DLL<br />
manually.<br />
To do so, drag the DLL to the icon of<br />
WINNT/System32/regsvr32.exe. Please<br />
look for error messages!<br />
1. Create a new Windows-user, e.g.<br />
novaUser<br />
2. Assign this user to the group of<br />
2005/106_FER<br />
2003/045_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
Microsoft VBScript...." is displayed. "Administrators".<br />
3. Open "Internet Services Manager"<br />
4. Open the property sheet of the virtual<br />
directory "WebScheduler"<br />
5. Select "Anonymous access" on tap<br />
"Directory Security" and assign the user<br />
defined before as "Anonymous user" to this<br />
virtual directory.<br />
16. Aug 02 1.00 Any user has the right to stop the scheduler<br />
server.<br />
22. WizReportXL<br />
03. Nov 06 After Deinstalling WizReportXL, MS Excel<br />
shows an error each time it is started,<br />
indicating that the files XLRcore.xla and<br />
XLRdesign.xla could not be found.<br />
23. ZP2400 Web<br />
22. Feb 06 2.00 ZP2400 Web does not install correctly<br />
under Windows2003 Server.<br />
Fr. Sauter <strong>AG</strong><br />
Seite 29 von 32<br />
Instead of starting the Scheduler with the<br />
Webscheduler object use the following<br />
hyperlink:<br />
http://sba01075/WebScheduler/Login/Login.<br />
asp?TARGET=TASKP<strong>AG</strong>EdUSERNAME=<br />
&PASSWORD=&TASKNAME=Light ,<br />
where "SBA01075" is the domain name and<br />
"Light" is the task.<br />
You have to disable (delete) the<br />
coresponding entries in the list of available<br />
Add-Ins (Menu Tools)<br />
1. Search the application aspnet_regiis.exe<br />
on your system.<br />
(normally it can be found under:<br />
C:\Windows\Microsoft.Net\Framework\v1.1.<br />
4322\..)<br />
2. Start the command line window CMD<br />
(Start/Execute/cmd)<br />
3. Change to folder<br />
2002/018_FER<br />
2006/140_PHo<br />
2006/113_SCP
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung<br />
C:\Windows\Microsoft.Net\Framework\v1.1.<br />
4322\ and execute the application<br />
aspnet_regiis.exe /i<br />
4. After termination you should get the<br />
message "Finished installing ASP.NET"<br />
5. Start the Internet Information Services<br />
(IIS) Manager from the control panel<br />
6. Check, if in folder "Web Service<br />
Extensions" the extension "ASP.NET" is in<br />
status "Allowed". If not, select it and click on<br />
button "Allow".<br />
Bezug<br />
07. Jul 05 2.10 Help is not displayed For the German help:<br />
2005/096_GSc<br />
• Copy the file „7001045001.pdf“ from<br />
C:\Program<br />
Files\Sauter\EY3600\novaPro_Open<br />
Suite\Documentation Deutsch\ZP2400 Web<br />
to C:\Inetpub\wwwroot\ZP2400\Texts\de<br />
• Rename file to „ZP2400_Web.pdf“<br />
h<br />
Fr. Sauter <strong>AG</strong><br />
Seite 30 von 32<br />
For the French help:<br />
• Copy the file „7001045002.pdf“ from<br />
C:\Program<br />
Files\Sauter\EY3600\novaPro_Open<br />
Suite\Documentation française\ZP2400<br />
Web to<br />
C:\Inetpub\wwwroot\ZP2400\Texts\fr<br />
• Rename file to „ZP2400_Web.pdf“<br />
For the English help:<br />
• Copy the file „7001045003.pdf“ from<br />
C:\Program<br />
Files\Sauter\EY3600\novaPro_Open<br />
Suite\Documentation English\ZP2400 Web<br />
to C:\Inetpub\wwwroot\ZP2400\Texts\en
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung<br />
• Rename file to „ZP2400_Web.pdf“<br />
Bezug<br />
09. Mrz 05 novaPro Open network constantly reports<br />
Please check the network properties of the 2005/088_FER<br />
about communication errors with other<br />
affected station.<br />
stations.<br />
This behaviour will result, if two PDM have<br />
the same station Id or station name<br />
16. Apr 04 1.12/2.0 Error message during the update of the<br />
Please make sure that on projects with data 2004/068_GSc<br />
users<br />
on a NTFS drive, all users get full access<br />
right for the folder with the file WizUm.mdb.<br />
(Select the folder with WizUM.mdb with the<br />
mouse, press the right mouse button,<br />
Properties, Tab "Security".)<br />
Folder Sharing has to be activated in<br />
projects with more than one PC, in order<br />
that all WizUM.mdb is visible from all PC's.<br />
h<br />
24. ZP3600 Web<br />
18. Aug 06 The user data base remains empty after<br />
importing the user data.<br />
The project path must not contain a "." (dot) 2006/130_FER<br />
22. Feb 06 2.00 ZP3600 Web does not install correctly<br />
Please refer to similar problem in section 2006/114_SCP<br />
under Windows2003 Server.<br />
ZP2400 Web<br />
28. Jun 05 2.00 Time programs and calendars can not be<br />
On PCs with processor speeds with more 2005/093_SCP<br />
read.<br />
than 1.5 GHz the parameter as followed<br />
has to be set:<br />
Projectfolder\Private_Data\ZP3600\initialize.ini<br />
sleep values for novaPro Open:<br />
20,10<br />
25. Starting<br />
10-Apr-08 2.2 Authentification error during login If the login generates an authetification<br />
error despite of correct datas, then it might<br />
be that the crypting RSA keys have been<br />
modified.<br />
The NSO-Support in Basle has a<br />
"cleanRSA-tool", which can correct the<br />
problem.<br />
2008/004_KIS<br />
Fr. Sauter <strong>AG</strong><br />
Seite 31 von 32
D100028842 Revision: 02<br />
FAQ for nova Pro Open _e Version: 01<br />
Datum<br />
seit<br />
Version<br />
Beschreibung Korr. ab Version Lösung Bezug<br />
10-Apr-08 3.0 NovaPro Open 3.0: invalid format during<br />
While starting an existing project with the 2008/005_KIS<br />
starting<br />
version NPO 3.0 it can be that a window<br />
opens to indicate an invalid format. The<br />
affected file there is .wza. A<br />
new project must be created, while the<br />
existing files are imported in a new<br />
application.<br />
26. Codesys<br />
10-Apr-08 Codesys2.3 Communication error codesys If while starting a nPO application a<br />
communication error is indicated, the<br />
following steps must be done: do not<br />
confirm the notification message now, start<br />
studio Codesys, log in, load program and<br />
confirm the notification message only now.<br />
If the notification message has been<br />
already confirmed, then the PC must be<br />
restarted.<br />
2008/006_KIS<br />
10-Apr-08 Codesys2.3 Studio codesys does not start. If while starting the studio Codesys nothing<br />
happens, the add-ons must be checked.<br />
Some of them were written for older<br />
versions and are no more compatible. This<br />
leads to incomprehensible consequences.<br />
2008/007_KIS<br />
27. Server 2003<br />
10-Apr-08 2.1 Slow loading of the pictures under server<br />
Optimization options of the server must be 2008/008_KIS<br />
2003<br />
adapted. Default setting counts to the<br />
services, the optimization of the programs<br />
must be chosen.<br />
28. Documentation<br />
10-Apr-08 2.0 Documentation in French There is a conflict between the screen<br />
views of tags in novaPro Open and the<br />
taglist (pages 12 and 13 of the textbook<br />
7001068002 S5). The list page 12 is the<br />
reference.<br />
2008/009_KIS<br />