MAIN MAIN COMPONENTS<br />

COMPONENTS<br />

• Main Main on-off on-off valves valves fitted to the suction and<br />

lines of each pump, ball type <strong>with</strong> threaded<br />

connectors up to series <strong>FH</strong> 50, butterfly type for<br />

<strong>FH</strong> 65 and <strong>FH</strong> 80 pumps.<br />

• Check Check valve valve on the delivery side of each pump,<br />

spring type <strong>with</strong> threaded connected up to 2",<br />

double-swing type between flanges over 2".<br />

For applications <strong>with</strong> air-cushion autoclaves, the<br />

check valves are mounted on the suction side and the<br />

unit is fitted <strong>with</strong> a G 1/2" threaded hose connector<br />

for the air supply (<strong>GS</strong>…RA series).<br />

• Suction Suction manifold manifold in AISI 304 stainless steel,<br />

threaded or flanged depending on the type of pump<br />

(see drawings). Threaded water inlet connector.<br />

• Delivery Delivery Delivery manifold manifold in AISI 304 stainless steel,<br />

threaded or flanged depending on the type of pump<br />

(see drawings). Threaded R1" connectors <strong>with</strong> relative<br />

caps for connecting expansion vessels.<br />

• Pressure Pressure gauge gauge and two two control<br />

control<br />

transmitters transmitters located on the delivery side of<br />

the unit.<br />

• Various arious fittings fittings in nickel-plated brass, galvanised<br />

steel or stainless steel depending on the version.<br />

• Support Support base base for pump unit and board bracket<br />

in painted steel.<br />

• Control Control Control panel panel protected to IP55.<br />

AVAILABLE AILABLE ST STANDARD ST ANDARD VERSIONS<br />

VERSIONS<br />

See material table.<br />

ST STANDARD ST ANDARD VERSION<br />

VERSION<br />

For or general general use<br />

use<br />

Ball valves in nickel-plated brass, butterfly valves in<br />

polyamide, check valves in brass or painted cast-iron<br />

<strong>with</strong> flaps in steel, plugs, splines and flanges galvanised<br />

steel; manifolds in A304.<br />

DW DW VERSION VERSION (<strong>GS</strong>../DW)<br />

(<strong>GS</strong>../DW)<br />

For or use use <strong>with</strong> <strong>with</strong> drinking drinking drinking water<br />

water<br />

The main components in contact <strong>with</strong> the fluid are<br />

certified for drinking water or made from AISI 304 or<br />

superior stainless steel.<br />

Valves in nickel-plated brass, butterfly valves in epoxy,<br />

check valves <strong>with</strong> flaps in AISI 304 steel;<br />

manifolds in A304.<br />

19<br />

AISI AISI 304 304 VERSION VERSION VERSION (<strong>GS</strong>../A304),<br />

(<strong>GS</strong>../A304),<br />

AISI AISI AISI 316 316 (<strong>GS</strong>../A316)<br />

(<strong>GS</strong>../A316)<br />

For or special special uses<br />

uses<br />

The manifolds, valves, check valves and the main<br />

elements <strong>with</strong> parts in direct contact <strong>with</strong> the fluid are<br />

made of AISI 304 or AISI 316 stainless steel.<br />

Optional Optional Optional accessories:<br />

accessories:<br />

• Dry-running Dry-running prevention<br />

prevention prevention devices in one of the<br />

following versions:<br />

- float switch, for positive heads;<br />

- pack of probe electrodes, for positive heads.<br />

• Autoclaves Autoclaves in the following versions:<br />

- Air-cushion autoclaves <strong>with</strong> compressor and<br />

accessories for autoclave and compressor.<br />

- Diaphragm autoclaves instead of air-cushion<br />

versions.<br />

• Diaphragm Diaphragm expansion expansion vessel vessel <strong>with</strong> ball valve<br />

(one for each pump) in the following versions,<br />

depending on the maximum head of the pumps:<br />

- Hydro tube kit 24 L 8 bar<br />

- Hydro tube kit 24 L 10 bar<br />

- Hydro tube kit 24 L 16 bar<br />

• Alarms Alarms kit kit; kit<br />

• Air Air suction suction suction for RA version;<br />

• Air Air compressor compressor for RA version;<br />

SPECIAL SPECIAL SPECIAL VERSIONS VERSIONS A AAVAILABLE<br />

A AILABLE ON<br />

ON<br />

REQUEST REQUEST<br />

REQUEST<br />

(Contact (Contact the the Sales Sales and and T TTechnical<br />

T echnical Assistance<br />

Assistance<br />

Service)<br />

Service)<br />

• Units <strong>with</strong> non-standard input voltages, such as<br />

three-phase 3x230V, 3x440V.<br />

• Units <strong>with</strong> single-phase input voltages 1x230V.<br />

• Jockey pump other than the standard ones illustrated<br />

in the catalogue.<br />

• Support base in AISI 304, AISI 316 stainless steel.<br />

• Units <strong>with</strong> stainless steel expansion vessels.<br />

• Units <strong>with</strong> special valves.<br />

• Units <strong>with</strong> 4 electric pumps (<strong>GS</strong>40...).<br />

• Units <strong>with</strong> 5 electric pumps (<strong>GS</strong>41... <strong>GS</strong>50...).<br />

• Units <strong>with</strong> 6 electric pumps (<strong>GS</strong>51... <strong>GS</strong>60...).<br />

<strong>GS</strong>.../<strong>FH</strong><br />

<strong>GS</strong>.../<strong>FH</strong>