07.08.2013 Views

Vapor Compression Refrigeration Cycle

Vapor Compression Refrigeration Cycle

Vapor Compression Refrigeration Cycle

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

HP<br />

HT<br />

<strong>Vapor</strong><br />

HP<br />

HT<br />

Liquid<br />

<strong>Vapor</strong> <strong>Compression</strong> <strong>Refrigeration</strong><br />

<strong>Cycle</strong><br />

LP<br />

LT<br />

<strong>Vapor</strong><br />

LP<br />

LT<br />

Liquid


ANALISIS GRAFICO DEL CICLO DE<br />

COMPRESION<br />

<strong>Compression</strong><br />

Re-expansion gas<br />

Volumetric efficiency<br />

<strong>Compression</strong> ratio<br />

Suction superheat<br />

Liquid slug<br />

Capacity reduction


CONTENIDO DE CALOR<br />

INCREMENTO DE TEMPERATURA


Liquido y vapor<br />

mezclados


P1<br />

EVAPORACION


P2<br />

CONDENSACION


P2<br />

P1<br />

EVAPORACION<br />

COMPRESION


P2<br />

P1<br />

EVAPORACION<br />

CONDENSACION<br />

COMPRESION


Expansion


P2<br />

P1<br />

EXPANCION<br />

CONDENSACION<br />

EVAPORACION COMPRESION


P2<br />

P1<br />

CICLO NORMAL Y CICLO ANORMAL (CAUSAS Y VARIANTES)<br />

EXPANSION


LOW SUCTION (EFECTS)


The Basic Single Stage Mechanical <strong>Refrigeration</strong> <strong>Cycle</strong><br />

PUMP DOWN, SOFT HOT GAS,<br />

KING HOT GAS, BLEED,<br />

EQUALIZE, CHILL,FAN<br />

DELAY, RUN, OIL, ICE, PANS<br />

FAN CONTROL,<br />

HOT GAS DEFROST<br />

BPR, CONDENSATE<br />

LATENT HEAT<br />

OF<br />

VAPORIZATION<br />

SUCTION TRAP<br />

TL, HLA, HLCO<br />

OIL POT, SC COIL, BO COIL<br />

TEV, HEV, HMMV<br />

20% FLASH GAS<br />

COMPLETED ITS<br />

WORK<br />

SLIGHTLY<br />

SUPERHEATED<br />

VAPOR<br />

OIL, OIL COOLING,<br />

FOAM, PUMP, HEATER<br />

HEAD, SPEED,<br />

TREATMENT,<br />

PURGE,<br />

PASSIFICATION<br />

LOAD, UNLOAD,<br />

START , STOP, FLA,<br />

CT, OIL, SUCTION,<br />

DISCHARGE, TEMP,<br />

PRESSURE ETC<br />

OIL RETURN<br />

LL OR LP, LSOV,<br />

HLCO<br />

PUMP, BYPASS, NPSH<br />

OL, LOL, DPCO, HEATER<br />

SV-1 KING VALVE, LSOV<br />

STRAINER<br />

CONTROL<br />

CALIBRATION<br />

LIQ-TRAP, HPR, PILOT-RCVR, C<br />

PURGER, HEAD PRESS CONT.<br />

DISIPA EL CALOR LATEN<br />

DE EVAPORACION<br />

CONDENSANDO EL REF.<br />

REMUEVE EL SUPERCALOR<br />

(CALOR SENSIBLE)<br />

VERY<br />

SUPERHEATED<br />

VAPOR (HEAT OF COMPRESSION ADDED)<br />

DIRECT OR INDIRECT<br />

OIL COOLING


Representacion grafica de la<br />

funcion de los componentes de un<br />

sistema de refrigeracion.


En la vida real calor exterior y calor de compresion tienen que ser considera<br />

Ganancia y perdida de calor influencia significativamente<br />

la capacidad de un sistema de refrigeracion


Ciclo teorico-ciclo real


AL BUSCAR AVERIAS DE TRES VALORES<br />

FISICOS COMUNES CONSIDERAREMOS SOLO<br />

DOS.<br />

• VOLUMEN (NO CAMBIA)<br />

• PRESION:<br />

• a).-Normal bajo las condiciones presentes de<br />

funcionamiento.<br />

• b).-Anormal (tiempo, causa y efecto).<br />

• TEMPERATURA:<br />

• a).- Corresponde a la presion leida ?.<br />

• b).-Condiciones internas y factores externos.


Ciclo de refrigeracion mecanica<br />

sobrepuesto a un diagrama PH<br />

COMUNMENTE EL PROBLEMA ESTA EN UNO DE LOS COMPONENTES VECINOS.


QUE HACE Y QUE DEBERIA ESTAR HACIENDO ??????.


Increasing Pressure (lb./sq. in. absolute)<br />

Transferencia de calor<br />

Subcooled<br />

Liquid<br />

Region<br />

Increasing Enthalpy (Btu/lb.)<br />

Pressure Enthalpy (P-h) Diagram<br />

(Mollier Diagram)<br />

Saturated Mixture of Liquid and <strong>Vapor</strong> Region<br />

Critical Point<br />

1651 psia and 270 0 F<br />

Superheated<br />

<strong>Vapor</strong><br />

Region


Increasing Pressure (lb./sq. in. absolute)<br />

Cambio de estado en el<br />

Subcooled<br />

Liquid<br />

Saturated<br />

Liquid<br />

Line<br />

A<br />

D<br />

Increasing Enthalpy (BTU/lb.)<br />

refrigerante<br />

Pressure Enthalpy (P-h) Diagram<br />

(Mollier Diagram)<br />

Condensation occurring along this line.<br />

Heat energy is leaving the system.<br />

Mixture of Saturated Liquid and <strong>Vapor</strong><br />

Evaporation occurring along this line.<br />

Heat energy is being absorbed into the system<br />

Critical<br />

Point<br />

B<br />

C<br />

Superheated<br />

<strong>Vapor</strong><br />

Saturated<br />

<strong>Vapor</strong> Line


Increasing Pressure (lb./sq. in. absolute)<br />

Porcentaje de liquido y vapor<br />

dentro del evaporador<br />

Sub-cooled<br />

Liquid<br />

100%<br />

Saturated<br />

Liquid<br />

A<br />

D<br />

A 1<br />

Heat energy used to<br />

cool refrigerant to<br />

evaporator temp.<br />

Increasing Enthalpy (BTU/lb.)<br />

Pressure Enthalpy Diagram<br />

(Mollier Diagram)<br />

87% Saturated Liquid,<br />

13% Saturated <strong>Vapor</strong><br />

Capacity to Absorb Heat<br />

Energy<br />

B<br />

Superheated<br />

<strong>Vapor</strong><br />

C<br />

0% liquid,<br />

100% Saturated<br />

<strong>Vapor</strong>


Relacion presion-temperatura de una descarga<br />

de 150 psig, bajo las siguientes condiciones<br />

Asumiendo<br />

condiciones de<br />

saturacion:<br />

25 psig = 12 grd. F<br />

150 psig = 85 grd. F<br />

En la zona de<br />

vapor<br />

sobrecalentado:<br />

Temp. teorica de<br />

descarga = 205<br />

grd. F.


Transferencia<br />

de calor<br />

durante la<br />

compresion<br />

25 psig = 12 grd. F<br />

150 psig = 85 grd. F<br />

Temp. teorica de<br />

descarga= 205 grd. F.


PARA QUE<br />

ANALIZAR TODA<br />

LA GRAFICA ?<br />

LAS CONDICIONES<br />

DE DESCARGA<br />

SE DAN<br />

EN ESTA AREA


Increasing Pressure (lb./sq. in. absolute)<br />

Trabajo de enfriamiento util de el<br />

refrigerante dentro del evaporador.<br />

Sub-cooled Liquid<br />

A<br />

D<br />

A 1<br />

Metering<br />

Device<br />

Increasing Enthalpy (BTU/lb.)<br />

Pressure Enthalpy Diagram<br />

(Mollier Diagram)<br />

Condensing<br />

Evaporation<br />

Saturated Mixture Region at<br />

Constant Temperature and Pressure<br />

B<br />

C<br />

C 1<br />

Superheated<br />

<strong>Vapor</strong><br />

Constant Entropy line


Si compriminos o subenfriamos<br />

liquido<br />

Tendriamos las siguiente<br />

representacion grafica


Si subenfriamos el liquido<br />

aumentamos la capacidad de<br />

refrigeracion<br />

del sistema


GOLPE DE LIQUIDO ?<br />

• CICLO DE COMPRESION.<br />

• EFICIENCIA VOLUMETRICA.<br />

• RESISTENCIA DE MATERIALES QUE<br />

COMPONEN AL COMPRESOR.<br />

• VALVULAS DE ALIVIO DE SOBRESION.


PRESSURE<br />

200<br />

150<br />

100<br />

50<br />

0<br />

C<br />

RE-EXPANSION<br />

RE EXPANSION<br />

Ciclo de compresion<br />

DESCARGA<br />

D<br />

B<br />

COMPRESION<br />

COMPRESION<br />

SUCTION<br />

0 10 20 30 40 50 60 70 80 90 100<br />

% of Cylinder Volume<br />

A – valvula de succion cierra<br />

B – valvula de descarga abre<br />

C – valvula de descarga cierra<br />

D – valvula de succion abre<br />

A


PRESSURE PSIA<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

Volumetric Efficiency<br />

<strong>Compression</strong> Ratio = 150/50 = 3<br />

Volumetric Efficiency = 81%<br />

C<br />

X<br />

D<br />

B<br />

0 10 20 30 40 50 60 70 80 90 100<br />

% of Cylinder Volume<br />

A – valvula de succion cierra<br />

B – valvula de descarga abre<br />

C – valvula de descarga cierra<br />

D – valvula de succion abre<br />

X - Re-expansion<br />

Re expansion<br />

81%<br />

A


PRESSURE PSIA<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

C<br />

Volumetric Efficiency<br />

X<br />

B<br />

D<br />

73%<br />

0 10 20 30 40 50 60 70 80 90 100<br />

% of Cylinder Volume<br />

A – valvula de succion cierra<br />

B – valvula de descarga abre<br />

C – valvula de descarga cierra<br />

D – valvula de succion abre<br />

X - Re-expansion<br />

Re expansion<br />

<strong>Compression</strong> Ratio = 225/50 = 4.5<br />

Volumetric Efficiency = 73%<br />

A


PRESSURE PSIA<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

Volumetric Efficiency<br />

<strong>Compression</strong> Ratio = 150/25 = 6<br />

Volumetric Efficiency = 65%<br />

C<br />

X<br />

B<br />

D<br />

0 10 20 30 40 50 60 70 80 90 100<br />

% of Cylinder Volume<br />

65%<br />

A - Suction Valve Closes<br />

B - Discharge Valve Opens<br />

C - Discharge Valve Closes<br />

D - Suction Valve Opens<br />

X - Re-expansion<br />

Re expansion<br />

A


PRESSURE PSIA<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

C<br />

X<br />

GOLPE DE LIQUIDO<br />

D<br />

B<br />

0 10 20 30 40 50 60 70 80 90 100<br />

% of Cylinder Volume<br />

A – cierra valvula de succion<br />

B – abre valvula de descarga<br />

C – cierra valvula de descarga<br />

D – abre valvula de succion<br />

X - Re-expansion<br />

Re expansion<br />

A


Todos los refrigerantes<br />

Tienen propiedades<br />

de saturacion definidas<br />

y exclusivas


Figura 5-13<br />

esquema de representación de un sistema de refrigeracíon de dos etapas<br />

simples


Two Stage Systems<br />

Increasing Pressure (lb./sq. in. absolute)<br />

Sub-cooled Liquid<br />

Increasing Enthalpy (Btu/lb.)<br />

• Two Stage <strong>Compression</strong><br />

A<br />

A 2<br />

D<br />

A 1<br />

Pressure Enthalpy Diagram<br />

(Mollier Diagram)<br />

Condensing<br />

Hi Stage Suction (evaporation & de-superheating)<br />

Low Stage Evaporation<br />

B<br />

C<br />

Superheated<br />

<strong>Vapor</strong><br />

Represents<br />

Efficiency Gained<br />

C 2<br />

C 1<br />

Constant Entropy line


Two Stage Systems<br />

Subcooled Liquid<br />

Region<br />

A<br />

A2<br />

Saturated Liquid<br />

Line<br />

D<br />

A 1<br />

Condensing Line<br />

Hi Stage Suction (evaporating and de-superheating) Line<br />

Low Stage Evaporating Line<br />

Mixture of Liquid and <strong>Vapor</strong><br />

at Constant Temperature and Pressure<br />

Saturated <strong>Vapor</strong> Line<br />

Increasing Pressure (lb./sq. in. absolute) Pressure Enthalpy Diagram (Mollier Diagram)<br />

Increasing Enthalpy (Btu/lb.)<br />

• Figure 7-4 Two Stage <strong>Compression</strong><br />

B<br />

C<br />

-28°<br />

C 2<br />

Superheated<br />

<strong>Vapor</strong> Region<br />

Constant Entropy<br />

Lines<br />

C 1<br />

110°<br />

Temperature<br />

Lines<br />

210° 320°


AHORA LA PARTE<br />

INTERESANTE<br />

•QUE SON Y PARA<br />

QUE SIRVEN LAS<br />

HOJAS MSDS.


M S D S<br />

•HOJAS DE DATOS DE<br />

SEGURIDAD DE UN<br />

MATERIAL EN<br />

PARTICULAR.


• Informacion general.<br />

AMONIACO<br />

• Composicion y apariencia del amoniaco.<br />

• Su efecto an el medio ambiente.<br />

• Efectos y consecuencias de exposicion.<br />

• Medidas de seguridad y equipo de proteccion.


(NO AFECTA LA CAPA<br />

DE OZONO EN LA<br />

ATMOSFERA)<br />

AMONIACO<br />

LO COMEMOS LO SUDAMOS<br />

LO ORINAMOS<br />

Y SU USO TIENE UNA GRAN<br />

CANTIDAD DE APLICACIONES.<br />

(SE ENCUENTRA EN<br />

FORMA NATURAL Y ES<br />

DEGENERATIVO)<br />

(PERO PUEDE SER<br />

AVISA DE SU<br />

PRESENCIA)<br />

SUMAMENTE PELIGROSO)


AMONIACO- COMPOSICION


CARACTERISTICAS FISICAS


STEL<br />

Lo que debe de saber sobre el amoniaco<br />

como minimo<br />

SHORT TERM EXPOSURE LIMIT<br />

(limite de exposicion en corto tiempo)<br />

TWA<br />

TIME WEIGHTED AVERAGE<br />

(tiempo promedio de exposicion)<br />

PEL<br />

ACGIH<br />

American Conference of Government Industrial Hygienists<br />

(Conferencia industrial de higiene del gobierno americano)<br />

FUEGO<br />

SALUD REACTIVIDAD<br />

0 = INSIGNIFICANTE<br />

1=LIGERO<br />

2=MODERADO<br />

3=ALTO<br />

PERMISSIBLE EXPOSURE LMIT<br />

(Limite permisible de exposicion)<br />

TLV<br />

Threshold Limit Values<br />

(Valores de exposicion<br />

limites)<br />

4=EXTREMO


Programas y equipo de seguridad para<br />

Amoniaco<br />

(hacen la diferencia)<br />

• Process Safety<br />

• (SEGURIDAD EN EL PROCESO)<br />

• Risk Management<br />

• (MANEJO DE RIEZGO)<br />

• Permit and Non- Permit Confined Space<br />

Entry<br />

• (PROCEDIMIENTOS PARA ENTRAR A<br />

ESPACIOS CERRADOS)<br />

• Lockout / Tagout Program.<br />

• Ammonia System Entry/Line Break<br />

• Stationary and Portable Ammonia Leak<br />

Detection


R717 AMONIACO NH3<br />

• ENTENDAMOSLO Y RESPETEMOSLO.<br />

• ESTABLECIENDO Y RESPETANDO REGLAS<br />

DE SEGURIDAD COMPROBADAS (POR LEY<br />

O POR SENTIDO COMUN).<br />

• USEMOS EL EQUIPO DE PROTECCION<br />

PERSONAL APROPIADO.<br />

• PLANEEMOS POR ADELANTADO LAS<br />

POSIBLES EVENTUALUIDADES (FUGAS)<br />

• CORDINANDO NUESTRO PLAN CON LAS<br />

AGENCIAS DE SERVICIO COMUNITARIO.<br />

• TRABAJANDO EN EQUIPO.


RECUERDE QUE LE ESPERAN EN SU CASA<br />

!!!.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!