[second stage]<br />

Hasta 15 m³/h GN<br />

[Till 15 m³/h NG]<br />

R4 / 18 mbar<br />

Pe Mín. [Min.Inlet Pressure]<br />

Pe Máx. [Max.Inlet Pressure]<br />

PS [Outlet Pressure]<br />

Seguridad [Safety]<br />

Capacidad Nominal [Nominal Capacity]<br />

Capacidad de Flujo [Flow Capacity]<br />

/ SEGUNDA ETAPA<br />

Código Conexión de Entrada Conexión de Salida<br />

[Code] [Input connector] [Output connector]<br />

410822<br />

R4 / 19 mbar<br />

Pe Mín. [Min.Inlet Pressure]<br />

Pe Máx. [Max.Inlet Pressure]<br />

PS [Outlet Pressure]<br />

Seguridad [Safety]<br />

Capacidad Nominal [Nominal Capacity]<br />

Capacidad de Flujo [Flow Capacity]<br />

R4 / 23 mbar<br />

Pe Mín. [Min.Inlet Pressure]<br />

Pe Máx. [Max.Inlet Pressure]<br />

PS [Outlet Pressure]<br />

Seguridad [Safety]<br />

Capacidad Nominal [Nominal Capacity]<br />

Capacidad de Flujo [Flow Capacity]<br />

0,34 bar ( 5 psi)<br />

2,7 bar (40 psi)<br />

18 mbar<br />

Válvula de Alivio<br />

2,43 m³(s)/h GN<br />

2,2 m³(s)/h GN<br />

Código Conexión de Entrada Conexión de Salida<br />

[Code] [Input connector] [Output connector]<br />

410835<br />

Código Conexión de Entrada Conexión de Salida<br />

[Code] [Input connector] [Output connector]<br />

410802<br />

½” NPT Macho ½” NPT h<br />

3/4” NPT h<br />

½” NPT Macho<br />

0,20 bar ( 2,9 psi)<br />

1,0 bar (14,5 psi)<br />

19 mbar<br />

Válvula de Alivio<br />

4,6 m³(s)/h GN<br />

3,6 m³(s)/h GN<br />

3/4” NPT h<br />

0,20 bar ( 3 psi)<br />

0,41 bar (6 psi)<br />

23 mbar<br />

Válvula de Alivio<br />

2,43 m³(s)/h GN<br />

2,2 m³(s)/h GN<br />

½” NPT h<br />

[second stage]<br />

<strong>GAS</strong><br />

NATURAL<br />

<strong>GAS</strong><br />

NATURAL<br />

R6 / 23 mbar<br />

Pe Mín. [Min.Inlet Pressure]<br />

0,21 bar ( 3,0 psi)<br />

Pe Máx. [Max.Inlet Pressure]<br />

0,35 bar (5 psi)<br />

PS [Outlet Pressure]<br />

23 mbar<br />

Seguridad [Safety]<br />

Válvula de Alivio<br />

Capacidad Nominal [Nominal Capacity] 4,38 m³(s)/h GN<br />

Capacidad de Flujo [Flow Capacity] 3,2 m³(s)/h GN<br />

Código Conexión de Entrada Conexión de Salida<br />

[Code] [Input connector] [Output connector]<br />

410907<br />

½” NPT h<br />

½” NPT h<br />

410910<br />

M26* 1,5 Macho<br />

½” NPT h<br />

R6 / 100 mbar<br />

Pe Mín. [Min.Inlet Pressure]<br />

0,21 bar ( 3,0 psi)<br />

Pe Máx. [Max.Inlet Pressure]<br />

0,42 bar (6 psi)<br />

PS [Outlet Pressure]<br />

100 mbar<br />

Seguridad [Safety]<br />

Válvula de Alivio<br />

Capacidad Nominal [Nominal Capacity] 4,0 m³(s)/h GN<br />

Capacidad de Flujo [Flow Capacity] 3,2 m³(s)/h GN<br />

Código Conexión de Entrada Conexión de Salida<br />

[Code] [Input connector] [Output connector]<br />

410908<br />

M26* 1,5 Macho<br />

½” NPT h<br />

410905<br />

½” NPT h<br />

½” NPT h<br />

R7 / 19 mbar<br />

Pe Mín. [Min.Inlet Pressure]<br />

Pe Máx. [Max.Inlet Pressure]<br />

PS [Outlet Pressure]<br />

Seguridad [Safety]<br />

Capacidad Nominal [Nominal Capacity]<br />

Capacidad de Flujo [Flow Capacity]<br />

Código Conexión de Entrada Conexión de Salida<br />

[Code] [Input connector] [Output connector]<br />

411008<br />

3/4” NPT h<br />

3/4” NPT h<br />

SEGUNDA ETAPA<br />

[second stage]<br />

0,35 bar (5 psi)<br />

1,0 bar (14,5psi)<br />

19 mbar<br />

Válvula de Alivio<br />

5,0 m³(s)/h GN<br />

5,0 m³(s)/h GN<br />

/<br />

Hasta 15 m³/h GN<br />

[Till 15 m3/h NG]<br />

SEGUNDA ETAPA<br />

[second stage]