10. EXAMPLES OF CONTROLLING ENTRANCES<br />

10.1 CONTROLLED ENTRANCE OR EXIT<br />

This solution is recommended when you want to enter a reserved area in just one direction activating a recognition command<br />

(radio control, proximity key, magnetic keys, etc.).<br />

The vehicle approaches<br />

the reserved area.<br />

- Connect the N.O. contact of the S1 loop receiver to input 27-29.<br />

- Connect the N.O. contact of the S2 loop receiver to input 28-29.<br />

- The dimensional values of the loops are only approximate.<br />

We suggest installing the “RM” metal mass detector.<br />

DIMENSIONS<br />

- 17 -<br />

When the vehicle is on loop S1 the<br />

device will move down only after a<br />

recognition command.<br />

If the device is moving back up<br />

and you want to lower it again<br />

the vehicle must be on loop S1<br />

and then you must activate the<br />

recognition command.<br />

When the vehicle is no longer<br />

on loop S2 the device will move<br />

back up.<br />

Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top.<br />