10.2 AUTOMATIC ENTRY OR EXIT<br />

This solution is recommended when you want to allow entry to a reserved area, entering or leaving without using the recognition<br />

commands, allowing transit of vehicles in just one direction.<br />

When the vehicle is on loop S0<br />

the device receives consent<br />

from loop S1 to move down.<br />

When the vehicle is on top<br />

of loops S0+S1 the device<br />

moves down automatically.<br />

When the vehicle is no longer<br />

on loop S2 the will move<br />

back up.<br />

Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top.<br />

ONE DIRECTION<br />

DIMENSIONS<br />

- Connect the N.O. contact of the S0 loop receiver to input 27-29.<br />

- Connect the N.O. contact of the S1 loop receiver to input 26-29<br />

and the N.C. contact to input 21-29.<br />

- Connect the N.O. contact of the S2 loop receiver to input 28-29.<br />

- The dimensional values of the loops are only approximate.<br />

We suggest installing the “RM” metal mass detector.<br />

*<br />

ONE DIRECTION<br />

ONE DIRECTION<br />

ONE DIRECTION<br />

- 18 -<br />

29<br />

1 2 3 4 5 6 7 8 9 10<br />

Setting the dip<br />

switches<br />

21<br />

26<br />

Detail of the connections between the “RM”<br />

presence relay and the control unit.<br />

*