PROGRAMMING<br />
Adjust the settings of all smoke alarms that are to be connected together at the same address. There are 8<br />
possible coding settings, selectable using a 3-pole DIP switch (1). Each combination represents a different radio<br />
channel.<br />
The MCSMOKE <strong>RF</strong> has a test button (2) for testing the correct functioning of the smoke alarm. After connection<br />
to the radio module, test all smoke alarms together.<br />
LED-status indicator<br />
Test procedure:<br />
Reset (3)<br />
Acoustic alarm<br />
LED-status indicator<br />
Test (2)<br />
LED functional indicator<br />
Press the RESET button (3) on the radio module. The red and green indicators should light once.<br />
Press the TEST button on the smoke alarm and keep it pressed. The smoke alarm that was triggered<br />
will now light, and the red indicator will flash. The red indicator on the radio module will now stay lit<br />
continuously.<br />
Do not release the TEST button, since the radio transmission is performed sequentially. Wait until the alarm<br />
is sounded at all the smoke alarms at the same address. The alarm at the REMOTE smoke alarms will<br />
sound, but the red indicator will not light. The red indicator on the radio module that was triggered will<br />
remain lit continuously .<br />
Release the TEST button on the smoke alarm that was triggered. The red indicator on the radio module<br />
will now stay lit until the RESET button is pressed. All indicators on the REMOTE smoke alarms will now be<br />
switched off automatically.<br />
Identification of the smoke alarm that has been triggered<br />
The smoke alarm that has been triggered can be identified by the red LED indicator staying lit continuously.<br />