Intended use<br />

<strong>Truma</strong> <strong>Duo<strong>Co</strong>mfort</strong> is an automatic<br />

changeover valve for use<br />

with a two-cylinder gas system.<br />

It permits replacement of a gas<br />

cylinders without interrupting<br />

the gas supply.<br />

The current removal status<br />

(“Normal” or “Reserve”) is<br />

shown directly on the valve. By<br />

adding a remote display (part no.<br />

50210-01), the changeover valve<br />

can be upgraded so that the removal<br />

status can be viewed from<br />

inside the vehicle.<br />

The <strong>Duo<strong>Co</strong>mfort</strong> must be operated<br />

in conjunction with a wallmounted<br />

gas pressure regulator,<br />

e.g. <strong>Truma</strong> SecuMotion, Mono-<br />

<strong>Co</strong>ntrol CS or model EN 61 DS<br />

10<br />

<strong>Duo<strong>Co</strong>mfort</strong><br />

gas pressure regulators manufactured<br />

by GOK (the use of other<br />

gas pressure regulators is not<br />

permitted). Two high pressure<br />

hoses are needed for connecting<br />

to the gas cylinders. If the gas<br />

system is going to be operated<br />

while driving, high-pressure hoses<br />

with hose rupture protection<br />

at the inlet side are required.<br />

Please pay attention to the<br />

<strong>Truma</strong> instructions concerning<br />

the use of the gas system while<br />

driving.<br />

<strong>Truma</strong> offers hoses with common<br />

connection fittings (see<br />

page 58 – 59) to enable use of<br />

gas cylinders with various valve<br />

connection sizes.<br />

To avoid disturbances in the gas<br />

system during winter operation,<br />

the <strong>Duo<strong>Co</strong>mfort</strong> changeover<br />

valve may be equipped with<br />

<strong>Truma</strong>’s “EisEx” regulator<br />

heating (part no. 53101-01).<br />

The use of this changeover<br />

valve is not permitted<br />

in confined spaces (e.g.<br />

in houses) or on boats, and in<br />

Germany it must not be used in<br />

caravan holiday homes.<br />

Pressure regulating devices<br />

and hoses must be<br />

replaced with new ones no more<br />

than 10 years after their date of<br />

manufacture (every 8 years if<br />

used commercially). This is the<br />

responsibility of the operator.