Intended use<br />
<strong>Truma</strong> <strong>Duo<strong>Co</strong>mfort</strong> is an automatic<br />
changeover valve for use<br />
with a two-cylinder gas system.<br />
It permits replacement of a gas<br />
cylinders without interrupting<br />
the gas supply.<br />
The current removal status<br />
(“Normal” or “Reserve”) is<br />
shown directly on the valve. By<br />
adding a remote display (part no.<br />
50210-01), the changeover valve<br />
can be upgraded so that the removal<br />
status can be viewed from<br />
inside the vehicle.<br />
The <strong>Duo<strong>Co</strong>mfort</strong> must be operated<br />
in conjunction with a wallmounted<br />
gas pressure regulator,<br />
e.g. <strong>Truma</strong> SecuMotion, Mono-<br />
<strong>Co</strong>ntrol CS or model EN 61 DS<br />
10<br />
<strong>Duo<strong>Co</strong>mfort</strong><br />
gas pressure regulators manufactured<br />
by GOK (the use of other<br />
gas pressure regulators is not<br />
permitted). Two high pressure<br />
hoses are needed for connecting<br />
to the gas cylinders. If the gas<br />
system is going to be operated<br />
while driving, high-pressure hoses<br />
with hose rupture protection<br />
at the inlet side are required.<br />
Please pay attention to the<br />
<strong>Truma</strong> instructions concerning<br />
the use of the gas system while<br />
driving.<br />
<strong>Truma</strong> offers hoses with common<br />
connection fittings (see<br />
page 58 – 59) to enable use of<br />
gas cylinders with various valve<br />
connection sizes.<br />
To avoid disturbances in the gas<br />
system during winter operation,<br />
the <strong>Duo<strong>Co</strong>mfort</strong> changeover<br />
valve may be equipped with<br />
<strong>Truma</strong>’s “EisEx” regulator<br />
heating (part no. 53101-01).<br />
The use of this changeover<br />
valve is not permitted<br />
in confined spaces (e.g.<br />
in houses) or on boats, and in<br />
Germany it must not be used in<br />
caravan holiday homes.<br />
Pressure regulating devices<br />
and hoses must be<br />
replaced with new ones no more<br />
than 10 years after their date of<br />
manufacture (every 8 years if<br />
used commercially). This is the<br />
responsibility of the operator.