In extreme cold or when a<br />
large amount of gas is<br />
consumed from the cylinder over<br />
a long period of time, the gas<br />
pressure may fall below 0.5 bar<br />
even though there is still some<br />
gas left in the cylinder. This may<br />
result in gas being taken from<br />
both gas cylinders simultaneously.<br />
If needed, you can change the<br />
position of the control knob at<br />
any time.<br />
Always turn control knob (a) as far<br />
to the left or right as it will go (an<br />
intermediate position will cause<br />
gas to be removed from both gas<br />
cylinders simultaneously).<br />
Removal status<br />
In the normal position (operating<br />
cylinder on the left, reserve cylinder<br />
on the right), the following<br />
display will be seen:<br />
12<br />
– status display (b) is green =<br />
gas taken from the left cylinder<br />
(operating cylinder).<br />
– status display (b) is red =<br />
gas is taken from the right cylinder<br />
(reserve cylinder); check<br />
connection and fill level of left<br />
cylinder.<br />
Changing cylinders<br />
Residual gas: No smoking!<br />
No open flames!<br />
<strong>Duo<strong>Co</strong>mfort</strong> enables replacement<br />
of an empty cylinder without<br />
interrupting the operation<br />
of devices currently consuming<br />
the gas. Non-return valves integrated<br />
into the inlet connecting<br />
piece prevent gas from escaping<br />
when only one gas cylinder is<br />
attached for a short time (see<br />
“Operating with only one gas<br />
cylinder”).<br />
– Turn the control knob (a) by<br />
180 degrees or half of a full<br />
turn until it stops and the<br />
former reserve cylinder<br />
becomes the operating<br />
cylinder. After the cylinder<br />
change the full gas cylinder is<br />
available again as the reserve<br />
cylinder.<br />
The status display (b) changes<br />
to green.<br />
– Close the empty cylinder’s<br />
valve and screw off the high<br />
pressure hose.<br />
– Screw the high pressure hose<br />
onto the full gas cylinder and<br />
open the cylinder’s valve;<br />
press the hose-break safety<br />
device if present.<br />
The status display (b) remains<br />
green.<br />
Anytime after making<br />
changes, check the hose