50 cm<br />

Roof slope<br />

CHIMNEY CAP: DISTANCES AND POSITIONING UNI 10683/98<br />

6. CONNECTION TO THE FLUE<br />

Distance between roof ridge and<br />

chimney<br />

Minimum height of chimney<br />

(measured from the outlet )<br />

¡ A (m) H (m)<br />

15°<br />

30°<br />

45°<br />

60°<br />

2 m 10 m<br />

1<br />

m<br />

min. H<br />

(1) In the case of adjacent flues, one chimney cap must rise above<br />

the other by at least 50 cm to prevent the transfer of pressure<br />

between the flues.<br />

(1) The chimney cap must not have any obstacles within 10 m from<br />

walls, pitch, and trees. In such case, it must be raised at least 1 m<br />

above the obstacles.<br />

The chimney cap must rise above the roof ridge by at least 1 m.<br />

¡<br />

>A<br />

< 1,85 m 0.50 m above the ridge<br />

> 1,85 m 1.00 m from roof<br />

< 1,50 m 0.50 m above the ridge<br />

> 1,50 m 1.30 m from roof<br />

< 1,30 m 0.50 m above the ridge<br />

> 1,30 m 2.00 m from roof<br />

< 1,20 m 0.50 m above the ridge<br />

> 1,20 m 2.60 m from roof<br />

Picture 10<br />

Picture 11<br />

Picture 12<br />

The connection to the flue (exhaust channel or pipe fitting) must be made using rigid pipes in aluminium plated steel<br />

with minimum thickness of 2 mm or in 316 stainless steel with minimum thickness of 1 mm.<br />

It is prohibited to use flexible metal pipes or asbestos cement pipes because they are subject to splitting or<br />

breakage, which can lead to fume leakage, jeopardising the safety of the connection itself.<br />

The diameter of opening for the connection to the connection of chimney must correspond to the smoke pipe diameter<br />

at least. The opening should have a connection to the wall to put inside the outlet pipe and a rose window.<br />

><br />

_ A<br />

(1)Ridge axis<br />

colmo<br />

(2)Roof<br />

6097811 Rev.06 – EN 25<br />